ADJUSTING AIR FLOW DIRECTION

Adjust the air flow direction properly. Failure to do so could cause discomfort and make an uneven room temperature distribution.

Adjust the vertical air flow using the remote control.

Adjust the horizontal air flow manually.

Adjusting the vertical air flow

The air conditioner automatically adjusts the vertical air flow direction according to the operating conditions when AUTO or A mode is selected.

To set a selected air flow direction

Use this function when the air conditioner is operating.

aFIX button

Hold down or briefly press the FIX button on the remote control to move the

louver in the desired direction.

Change the vertical air flow louver direction within the range indicated.

In subsequent operations, the vertical air flow is automatically set to the direction that you set the louver using the FIX button.

To automatically swing the air flow direction

Perform this function when the air conditioner is operating.

aSWING button

Press the SWING button on the remote control.

To stop the function, press the SWING button.

To change the swing direction, press the FIX button.

CAUTION

The FIX and SWING buttons will be disabled when the air conditioner is not operating (including when ON TIMER is set).

Do not operate the air conditioner for an extended period of time with the air flow direction set downward during the cooling or dry operation. Otherwise, condensation may occur on the surface of the vertical air flow louver and cause water dripping.

Do not move the vertical air flow louver manually. Always use the FIX button. If you move the louver manually, it may malfunction during operation.

If the louver malfunctions, stop the air conditioner once, and restart.

When the air conditioner is started immediately after it was stopped, the vertical air flow louver might not move for about 10 seconds.

Adjusting the horizontal air flow

Preparation:

Grasp the lever on the horizontal air flow louver and move them to adjust the air flow direction as required.

You can adjust the air flow at the left and right locations of the grilles.

PAP

 

 

AUTO

 

TEMP

 

MODE

 

 

PRESET

HiPOWER

ECO

MEMO

a

 

 

1.3.5.9H

 

 

 

SWING

FIX

FAN

SLEEP

CLR

 

 

SET

CLOCK

ON

OFF

FILTER

 

 

RESET

 

 

 

 

CHECK

 

 

 

PAP

 

 

AUTO

 

 

TEMP

 

 

MODE

 

 

PRESET

 

HiPOWER

ECO

MEMO

a

 

 

 

1.3.5.9H

SWING

FIX

FAN

SLEEP

 

CLR

 

 

SET

 

CLOCK

ON

OFF

FILTER

 

 

 

 

RESET

 

 

 

 

 

CHECK

 

 

EN

14

Image 15
Contents Acondicionador DE Aire Tipo Separado Climatiseur Type SepareKlimagerät Geteilte Ausführung Condizionatore D’ARIA Tipo SplitOperation Warnings Accessories AIR Filter ComponentsSafety Precautions Installation WarningsOperation Cautions Installation CautionsIndoor unit Reset buttonNames of Parts Outdoor unitRemote Control and ITS Functions Display Names and Functions of Indicators on Remote ControlLoading the remote control batteries Preparation and Check Before USEPreparing the filters Setting the clockInitial setting Adjusting the clockInstalling the remote control holder Using the Remote ControlLocation of the remote control Remote control holderStop Automatic OperationAutomatic Operation Auto Changeover StartDRY Operation COOLING/HEATING OperationTo stop only PAP operation When the air conditioner is stoppedAIR Purifying Operation During air conditioner operationCanceling Hi Power mode Timer OperationHigh power Hi Power Setting Hi Power modeClock display On timer OFF timer Stop Operation StopCancelling timer operation Setting combined TimerMEMORY/PRESET Operation When the Preset button is pressed during operationMemo button To set a selected air flow direction Adjusting AIR Flow DirectionAdjusting the vertical air flow Adjusting the horizontal air flow PreparationHOW to SET Auto Restart HOW to Cancel Auto RestartAuto Restart Operation ECO operation Hi Power operationHOW the AIR Conditioner Works Automatic OperationDRY operation Maintain room temperature at a comfortable levelTemporary Operation Hints for Economical OperationCleaning the air filter Usual MaintenanceCleaning of indoor unit and remote control When not using the unit for at least 1 monthCleaning the air inlet grille Items sold separately Special MaintenanceCleaning the Zeolite-plus filter and Zeolite-3G filter Attaching the Zeolite-plus filter and Zeolite-3G filterEnglish Français Deutsch Italiano Cleaning the dust collecting unitPage AIR Conditioner Operation and Performance Troubleshooting Recheck InoperativePoor cooling or heating performance Room air is smelly Bad odor comes from the air conditioner Operation indicator turns on and offCondensation forms on the back of the indoor unit Indoor unit or outdoor unit makes a strange noiseThese are not defects Filter indicator turns on Sounds made from the indoor unitSounds made from the outdoor unit Specifications For cooling For heating Air inlet temperature CReverse cycle, Split type DRY Settings Cannot be ChangedSignal Receiving Tone Does Not Sound AutoDeclaration of Conformity

RAS-10JAVP-E, RAS-10JKVP-E, RAS-13JKVP-E, RAS-13JAVP-E specifications

Toshiba is renowned for its advanced air conditioning systems that offer reliable performance and innovative features tailored for diverse environments. The Toshiba RAS-13JAVP-E, RAS-13JKVP-E, RAS-10JKVP-E, and RAS-10JAVP-E models exemplify the brand's commitment to quality and efficiency.

These units are equipped with cutting-edge inverter technology, allowing them to adjust their compressor speed according to the cooling or heating demands of the space, resulting in significant energy savings and stable temperature control. With their ability to operate on low power while maintaining efficiency, these models contribute to lower electricity bills, making them an eco-friendly choice for homeowners and businesses alike.

The RAS-13JAVP-E and RAS-13JKVP-E cater to larger areas with a cooling capacity of 13,000 BTU, while the RAS-10JKVP-E and RAS-10JAVP-E are designed for slightly smaller spaces with a 10,000 BTU output. This versatility makes these units suitable for various installations, from residential spaces to small commercial settings.

Additionally, all four models feature a sleek and modern design, blending seamlessly with contemporary interiors. The user-friendly interface, complete with a remote control, allows for easy operation and program settings, enhancing the overall user experience.

Another key characteristic of these Toshiba units is their advanced air purification technology. Equipped with a high-performance filter system, they effectively remove dust, allergens, and pollutants from the air, ensuring a cleaner and healthier environment for occupants.

Moreover, the units boast a quiet operation mode, making them ideal for bedrooms and offices where noise sensitivity is a concern. The indoor noise level is minimized without compromising performance, allowing for undisturbed relaxation or productivity.

Durability is another hallmark of Toshiba air conditioning systems. These models are built with high-quality materials, designed to withstand varying climates and ensure longevity.

In conclusion, the Toshiba RAS-13JAVP-E, RAS-13JKVP-E, RAS-10JKVP-E, and RAS-10JAVP-E air conditioners represent a perfect blend of efficiency, comfort, and reliability. Their innovative technologies, energy-saving attributes, and superior air quality features make them standout options for anyone looking to enhance their indoor environment.