Setting the clock

Before you start operating the air conditioner, set the clock of the remote control using the procedures given in this section. The clock panel on the remote control will indicate the time regardless of whether the air conditioner is in use or not.

Initial setting

When batteries are inserted in the remote control, the clock panel displays AM 0:00 and flashes.

a ON ON button

Press the ON ON button to set the current time.

Each press of the ON button changes the time in one minute increments. Holding down the ON button changes the time in ten minute increments.

b SET SET button

Press the SET SET button.

The current time is displayed and the clock starts.

 

PAP

 

 

AUTO

 

 

TEMP

 

 

MODE

 

 

PRESET

 

HiPOWER

ECO

MEMO

 

 

 

 

1.3.5.9H

b

SWING

FIX

FAN

SLEEP

CLR

 

 

SET

a

 

 

CLOCK

ON

OFF

FILTER

 

 

 

RESET

 

 

 

 

 

CHECK

 

 

Adjusting the clock

aCLOCK button

Press the CLOCK button. The CLOCK indicator flashes.

b ON ON button

Press the ON ON button to set the current

time.

Each press of the ON button changes the time in one minute increments.

Holding down the ON button changes the time in ten minute increments.

HiPOWER ECO MEMO

1.3.5.9H

SWING FIX FAN SLEEP

CLR

 

SET

ON

OFF

FILTER

CLOCK

 

 

 

CHECK

 

 

Push CLOCK

PAPAUTO

TEMP

MODEPRESET

HiPOWER ECO MEMO

c SET SET button

Press the SET SET button.

b

a

The current time is displayed and the clock

starts.

 

Preparing the filters

aOpen the air inlet grille, and remove the air filters.

b Attach the supplied Zeolite-plus filter and Zeolite-3G filter.

1.3.5.9H

SWING FIX FAN SLEEP

CLR

 

SET

c

ON

OFF

FILTER

 

CLOCK

 

 

 

 

 

RESET

 

 

 

CHECK

 

 

 

Zeolite-3G filter

Zeolite-plus filter

EN

6

Image 7
Contents Acondicionador DE Aire Tipo Separado Climatiseur Type SepareKlimagerät Geteilte Ausführung Condizionatore D’ARIA Tipo SplitOperation Warnings Accessories AIR Filter ComponentsSafety Precautions Installation WarningsOperation Cautions Installation CautionsIndoor unit Reset buttonNames of Parts Outdoor unitRemote Control and ITS Functions Display Names and Functions of Indicators on Remote ControlLoading the remote control batteries Preparation and Check Before USEPreparing the filters Setting the clockInitial setting Adjusting the clockInstalling the remote control holder Using the Remote ControlLocation of the remote control Remote control holderStop Automatic OperationAutomatic Operation Auto Changeover StartDRY Operation COOLING/HEATING OperationTo stop only PAP operation When the air conditioner is stoppedAIR Purifying Operation During air conditioner operationCanceling Hi Power mode Timer OperationHigh power Hi Power Setting Hi Power modeClock display On timer OFF timer Stop Operation StopCancelling timer operation Setting combined TimerWhen the Preset button is pressed during operation MEMORY/PRESET OperationMemo button To set a selected air flow direction Adjusting AIR Flow DirectionAdjusting the vertical air flow Adjusting the horizontal air flow PreparationHOW to Cancel Auto Restart HOW to SET Auto RestartAuto Restart Operation ECO operation Hi Power operationHOW the AIR Conditioner Works Automatic OperationDRY operation Maintain room temperature at a comfortable levelTemporary Operation Hints for Economical OperationCleaning the air filter Usual MaintenanceCleaning of indoor unit and remote control When not using the unit for at least 1 monthCleaning the air inlet grille Items sold separately Special MaintenanceCleaning the Zeolite-plus filter and Zeolite-3G filter Attaching the Zeolite-plus filter and Zeolite-3G filterEnglish Français Deutsch Italiano Cleaning the dust collecting unitPage AIR Conditioner Operation and Performance Recheck Inoperative TroubleshootingPoor cooling or heating performance Room air is smelly Bad odor comes from the air conditioner Operation indicator turns on and offCondensation forms on the back of the indoor unit Indoor unit or outdoor unit makes a strange noiseSounds made from the indoor unit These are not defects Filter indicator turns onSounds made from the outdoor unit For cooling For heating Air inlet temperature C SpecificationsReverse cycle, Split type DRY Settings Cannot be ChangedSignal Receiving Tone Does Not Sound AutoDeclaration of Conformity

RAS-10JAVP-E, RAS-10JKVP-E, RAS-13JKVP-E, RAS-13JAVP-E specifications

Toshiba is renowned for its advanced air conditioning systems that offer reliable performance and innovative features tailored for diverse environments. The Toshiba RAS-13JAVP-E, RAS-13JKVP-E, RAS-10JKVP-E, and RAS-10JAVP-E models exemplify the brand's commitment to quality and efficiency.

These units are equipped with cutting-edge inverter technology, allowing them to adjust their compressor speed according to the cooling or heating demands of the space, resulting in significant energy savings and stable temperature control. With their ability to operate on low power while maintaining efficiency, these models contribute to lower electricity bills, making them an eco-friendly choice for homeowners and businesses alike.

The RAS-13JAVP-E and RAS-13JKVP-E cater to larger areas with a cooling capacity of 13,000 BTU, while the RAS-10JKVP-E and RAS-10JAVP-E are designed for slightly smaller spaces with a 10,000 BTU output. This versatility makes these units suitable for various installations, from residential spaces to small commercial settings.

Additionally, all four models feature a sleek and modern design, blending seamlessly with contemporary interiors. The user-friendly interface, complete with a remote control, allows for easy operation and program settings, enhancing the overall user experience.

Another key characteristic of these Toshiba units is their advanced air purification technology. Equipped with a high-performance filter system, they effectively remove dust, allergens, and pollutants from the air, ensuring a cleaner and healthier environment for occupants.

Moreover, the units boast a quiet operation mode, making them ideal for bedrooms and offices where noise sensitivity is a concern. The indoor noise level is minimized without compromising performance, allowing for undisturbed relaxation or productivity.

Durability is another hallmark of Toshiba air conditioning systems. These models are built with high-quality materials, designed to withstand varying climates and ensure longevity.

In conclusion, the Toshiba RAS-13JAVP-E, RAS-13JKVP-E, RAS-10JKVP-E, and RAS-10JAVP-E air conditioners represent a perfect blend of efficiency, comfort, and reliability. Their innovative technologies, energy-saving attributes, and superior air quality features make them standout options for anyone looking to enhance their indoor environment.