Toshiba RAS-13JKVP-E Special Maintenance, Attaching the Zeolite-plus filter and Zeolite-3G filter

Page 21

SPECIAL MAINTENANCE

Attaching the Zeolite-plus filter and Zeolite-3G filter

After installing the air conditioner, attach the supplied Zeolite-plus filter and Zeolite-3G filter.

Preparation:

1.Turn off the air conditioner using the remote control.

INFORMATION

It is recommended that you replace the filters once about every six years.

Deodorizing performance will drop when there are severe stains due to extended periods of usage such as due to tar accumulation from cigarette smoke.

1Open the air inlet grille.

Lift up the air inlet grille until it clicks into place.

2Take off the air filter from the left side.

Grasp the left and right handles of the air filter and lift up slightly and then pull downward to remove the filter from the filter holder.

3Attach the Zeolite-plus filter and Zeolite-3G filter to the front panel.

When attaching new filters, remove the Zeolite-plus filter and Zeolite-3G filter from the bag, and then insert the filters with the Zeolite-plus filter on the top.

4Attach the air filter, and then close the air inlet grille.

Cleaning the Zeolite-plus filter and Zeolite-3G filter

Clean the filters when you clean the dust collecting unit. (Clean approximately once every six months.)

Preparation:

1.Turn off the air conditioner using the remote control.

1Open the air inlet grille.

Lift up the air inlet grille until it clicks into place.

2Grasp the left and right handles of the air filter and lift up slightly and then pull downward to remove the filter from the filter holder.

3Remove the Zeolite-plus filter and Zeolite-3G filter from the front panel.

4Wash the Zeolite-plus filter and Zeolite-3G filter in water, and then drain.

If the filters are dirty with dust and dirt, use a vacuum cleaner to remove the dirt before washing with water. Also, be sure to always use clean water when washing. If dirty water is used, the debris in the water can adhere to the filters.

Do not rub the filter surface.

In the final of the water washing, be sure to always rinse the filter with clean water.

If the filter is particularly dirty, add a neutral detergent at the standard concentration and then rinse with clean water until there are no more soap bubbles.

Drain gently after washing with water.

5Allow the Zeolite-plus filter and Zeolite-3G filter to dry in the sun.

• It takes about six hours for the filters to dry in direct sunlight.

6Attach the air filter, and then close the air inlet grille.

Items sold separately

Zeolite-plus filter (RB-A607DE) Zeolite-3G filter (RB-A608DE)

EN

20

Image 21
Contents Klimagerät Geteilte Ausführung Climatiseur Type SepareCondizionatore D’ARIA Tipo Split Acondicionador DE Aire Tipo SeparadoSafety Precautions Accessories AIR Filter ComponentsInstallation Warnings Operation WarningsOperation Cautions Installation CautionsNames of Parts Reset buttonOutdoor unit Indoor unitRemote Control and ITS Functions Loading the remote control batteries Names and Functions of Indicators on Remote ControlPreparation and Check Before USE DisplayInitial setting Setting the clockAdjusting the clock Preparing the filtersLocation of the remote control Using the Remote ControlRemote control holder Installing the remote control holderAutomatic Operation Auto Changeover Automatic OperationStart StopDRY Operation COOLING/HEATING OperationAIR Purifying Operation When the air conditioner is stoppedDuring air conditioner operation To stop only PAP operationHigh power Hi Power Timer OperationSetting Hi Power mode Canceling Hi Power modeCancelling timer operation On timer OFF timer Stop Operation StopSetting combined Timer Clock displayMEMORY/PRESET Operation When the Preset button is pressed during operationMemo button Adjusting the vertical air flow Adjusting AIR Flow DirectionAdjusting the horizontal air flow Preparation To set a selected air flow directionHOW to SET Auto Restart HOW to Cancel Auto RestartAuto Restart Operation HOW the AIR Conditioner Works Hi Power operationAutomatic Operation ECO operationTemporary Operation Maintain room temperature at a comfortable levelHints for Economical Operation DRY operationCleaning of indoor unit and remote control Usual MaintenanceWhen not using the unit for at least 1 month Cleaning the air filterCleaning the air inlet grille Cleaning the Zeolite-plus filter and Zeolite-3G filter Special MaintenanceAttaching the Zeolite-plus filter and Zeolite-3G filter Items sold separatelyEnglish Français Deutsch Italiano Cleaning the dust collecting unitPage AIR Conditioner Operation and Performance Troubleshooting Recheck InoperativePoor cooling or heating performance Condensation forms on the back of the indoor unit Operation indicator turns on and offIndoor unit or outdoor unit makes a strange noise Room air is smelly Bad odor comes from the air conditionerThese are not defects Filter indicator turns on Sounds made from the indoor unitSounds made from the outdoor unit Specifications For cooling For heating Air inlet temperature CReverse cycle, Split type Signal Receiving Tone Does Not Sound Settings Cannot be ChangedAuto DRYDeclaration of Conformity

RAS-10JAVP-E, RAS-10JKVP-E, RAS-13JKVP-E, RAS-13JAVP-E specifications

Toshiba is renowned for its advanced air conditioning systems that offer reliable performance and innovative features tailored for diverse environments. The Toshiba RAS-13JAVP-E, RAS-13JKVP-E, RAS-10JKVP-E, and RAS-10JAVP-E models exemplify the brand's commitment to quality and efficiency.

These units are equipped with cutting-edge inverter technology, allowing them to adjust their compressor speed according to the cooling or heating demands of the space, resulting in significant energy savings and stable temperature control. With their ability to operate on low power while maintaining efficiency, these models contribute to lower electricity bills, making them an eco-friendly choice for homeowners and businesses alike.

The RAS-13JAVP-E and RAS-13JKVP-E cater to larger areas with a cooling capacity of 13,000 BTU, while the RAS-10JKVP-E and RAS-10JAVP-E are designed for slightly smaller spaces with a 10,000 BTU output. This versatility makes these units suitable for various installations, from residential spaces to small commercial settings.

Additionally, all four models feature a sleek and modern design, blending seamlessly with contemporary interiors. The user-friendly interface, complete with a remote control, allows for easy operation and program settings, enhancing the overall user experience.

Another key characteristic of these Toshiba units is their advanced air purification technology. Equipped with a high-performance filter system, they effectively remove dust, allergens, and pollutants from the air, ensuring a cleaner and healthier environment for occupants.

Moreover, the units boast a quiet operation mode, making them ideal for bedrooms and offices where noise sensitivity is a concern. The indoor noise level is minimized without compromising performance, allowing for undisturbed relaxation or productivity.

Durability is another hallmark of Toshiba air conditioning systems. These models are built with high-quality materials, designed to withstand varying climates and ensure longevity.

In conclusion, the Toshiba RAS-13JAVP-E, RAS-13JKVP-E, RAS-10JKVP-E, and RAS-10JAVP-E air conditioners represent a perfect blend of efficiency, comfort, and reliability. Their innovative technologies, energy-saving attributes, and superior air quality features make them standout options for anyone looking to enhance their indoor environment.