Toshiba RAV-SM562AT-E, RAV-SM802XT-E Detachments, Remove the Panel arms from the Front panel

Page 29

FILE NO. SVM-06012

10. DETACHMENTS

10-1. Indoor Unit

No.

Part name

Procedures

Remarks

1Air Inlet grille <How to remove the Air inlet grille>

1)Stop the operation of the Air conditioner and turn off its main power supply.

2)Open the Air inlet grille with both hands.

Air inlet grille

3)Unfasten 3 screws (about two to three rounds) for fixing the Panel arms.

4)Move the Air inlet grille toward.

Panel arm

5)Remove the Grille stopper from the axis of the Front panel. After that, remove the Air inlet grille.

Grille stopper

 

Air inlet grille

6) Remove the Panel arms from the Front panel.

Panel arm

<How to install the Air inlet grille>

1)Insert three Panel arms on the Air inlet grille and fix each securely by screws.

2) Set the Air inlet grille arm to the axis of the Front panel.

3)Insert the Grille stopper to the correct position and fix it securely with screws.

4)Push the Air inlet grille to the correct position.

27 –

Image 29
Contents AIR-CONDITIONER Contents Specifications Current Operation characteristic curve Cooling HeatingIndoor Unit Construction ViewsRAV-SM562XT-E / RAV-SM802XT-E Systematic Refrigerating Cycle DiagramColor Identification Wiring DiagramParts name Type Specifications Specification of Electrical PartsRefrigerant Piping Installation Safety During Installation/ServicingRefrigerant R410A Piping materials and joints usedProcessing of piping materials 1 Thicknesses of annealed copper pipes Thickness mmOuter diameter mm R410A R22 Clutch type Wing nut type Flare tool for R410A Conventional flare toolFlare tool for R22 Conventional flare tool Width Diameter·m kgf·m ·m kgf·cmGeneral tools Conventional tools can be used ToolsRequired tools Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Types of flux Noncorrosive flux Characteristics required for fluxActivated flux Filler FluxPRE DEF Control Block DiagramOperation mode selection When power supply is resetAir volume control Operation Description1 Cold draft preventing control Cool air discharge preventive controlHigh-temp release control Freeze preventive control Low temperature releaseLouver control Filter sign displayAuto Restart Function How to set auto restart functionOperation MotionsPower failure during timer operation How to cancel auto restart functionHow to turn off filter check lamp Filter Check LampSummary of Troubleshooting TroubleshootingBefore troubleshooting Troubleshooting procedureHow to use remote control in service mode Self-Diagnosis by Remote Control Check CodeJudgement and action No display in the setting at shipment Operation Caracteristics-3 TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-220 TE, TO, TS sensor TD sensor Caracteristics-4Remove the Panel arms from the Front panel How to install the Air inlet grilleDetachments Open 3 Cap screws and remove the screws How to remove the Drain pan Refrigeration How to remove the Refrigeration assembly Assembly Pan assemblyFan motor Part name Procedures RemarksHow to remove the Multiblade fan Indoor Unit E-Parts Assy Exploded Views and Parts ListAIR-GRILLE