Toshiba RAV-SM562AT-E, RAV-SM802XT-E, RAV-SM802AT-E service manual Construction Views, Indoor Unit

Page 5

FILE NO. SVM-06012

2. CONSTRUCTION VIEWS

2-1. Indoor Unit

Front panel

1093

208

 

633

Knock out system

 

 

 

Grille air inlet

 

 

 

 

Back body

 

For stud bolt

200 Min

1093

Installation plate

 

(Ø8 – Ø10)

 

1015

 

For stud bolt (Ø6)

 

742

 

 

 

 

450

Mount plate

 

 

 

 

 

20

 

 

 

 

20

 

 

 

 

 

 

M10 Suspention bolt

 

 

330

 

633

 

 

 

 

 

460

 

 

 

165

 

 

 

160

 

 

 

Min

57

18

 

 

 

70

Wireless remote control

 

 

 

 

UNDER CEILING & CONSOLE INSTALLATION

Knock out system

 

– 3 –

Image 5
Contents AIR-CONDITIONER Contents Specifications Current Operation characteristic curve Cooling HeatingIndoor Unit Construction ViewsRAV-SM562XT-E / RAV-SM802XT-E Systematic Refrigerating Cycle DiagramColor Identification Wiring DiagramParts name Type Specifications Specification of Electrical PartsRefrigerant Piping Installation Safety During Installation/ServicingRefrigerant R410A Piping materials and joints usedProcessing of piping materials 1 Thicknesses of annealed copper pipes Thickness mmOuter diameter mm R410A R22 Clutch type Wing nut type Flare tool for R410A Conventional flare toolFlare tool for R22 Conventional flare tool Width Diameter·m kgf·m ·m kgf·cmGeneral tools Conventional tools can be used ToolsRequired tools Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Types of flux Noncorrosive flux Characteristics required for fluxActivated flux Filler FluxPRE DEF Control Block DiagramOperation mode selection When power supply is resetAir volume control Operation Description1 Cold draft preventing control Cool air discharge preventive controlHigh-temp release control Freeze preventive control Low temperature releaseLouver control Filter sign displayAuto Restart Function How to set auto restart functionOperation MotionsPower failure during timer operation How to cancel auto restart functionHow to turn off filter check lamp Filter Check LampSummary of Troubleshooting TroubleshootingBefore troubleshooting Troubleshooting procedureHow to use remote control in service mode Self-Diagnosis by Remote Control Check CodeJudgement and action No display in the setting at shipment Operation Caracteristics-3 TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-220 TE, TO, TS sensor TD sensor Caracteristics-4Remove the Panel arms from the Front panel How to install the Air inlet grilleDetachments Open 3 Cap screws and remove the screws How to remove the Drain pan Refrigeration How to remove the Refrigeration assembly Assembly Pan assemblyFan motor Part name Procedures RemarksHow to remove the Multiblade fan Indoor Unit E-Parts Assy Exploded Views and Parts ListAIR-GRILLE
Related manuals
Manual 18 pages 35.13 Kb