Toshiba RAV-SM802XT-E, RAV-SM802AT-E, RAV-SM562AT-E Open 3 Cap screws and remove the screws

Page 30

FILE NO. SVM-06012

No.

Part name

Procedures

Remarks

2Front panel <How to remove the Front panel>

1)Remove the Air inlet grille. (1)

2)In case of the Drain hose is installed through the Front panel.

:Remove the Drain band from the Front panel.

:Cut away the Opening base for piping from Front panel and keep parts.

Drain band

Drain panel

 

3)Open 3 Cap screws and remove the screws.

Cap screws

4) Remove 5 screws fixing the Front panel.

Front Panel

5)Remove the hooks of the Panel LED nearly side from the Drain pan.

Screws

(Continue)

– 28 –

Image 30
Contents AIR-CONDITIONER Contents Specifications Operation characteristic curve Cooling Heating CurrentConstruction Views Indoor UnitSystematic Refrigerating Cycle Diagram RAV-SM562XT-E / RAV-SM802XT-EWiring Diagram Color IdentificationSpecification of Electrical Parts Parts name Type SpecificationsRefrigerant R410A Safety During Installation/ServicingRefrigerant Piping Installation Piping materials and joints used1 Thicknesses of annealed copper pipes Thickness mm Outer diameter mm R410A R22Processing of piping materials Flare tool for R22 Conventional flare tool Flare tool for R410A Conventional flare toolClutch type Wing nut type Width Diameter·m kgf·cm ·m kgf·mTools Required toolsGeneral tools Conventional tools can be used 1 Configuration of refrigerant charging Recharging of RefrigerantBrazing of Pipes Activated flux Characteristics required for fluxTypes of flux Noncorrosive flux Filler FluxControl Block Diagram PRE DEFAir volume control When power supply is resetOperation mode selection Operation DescriptionCool air discharge preventive control 1 Cold draft preventing controlLouver control Freeze preventive control Low temperature releaseHigh-temp release control Filter sign displayOperation How to set auto restart functionAuto Restart Function MotionsHow to turn off filter check lamp How to cancel auto restart functionPower failure during timer operation Filter Check LampBefore troubleshooting TroubleshootingSummary of Troubleshooting Troubleshooting procedureSelf-Diagnosis by Remote Control Check Code How to use remote control in service modeJudgement and action No display in the setting at shipment Operation 20 TE, TO, TS sensor TA sensor TC, TCJ sensor Caracteristics-1 Caracteristics-2Caracteristics-3 TD sensor Caracteristics-4How to install the Air inlet grille DetachmentsRemove the Panel arms from the Front panel Open 3 Cap screws and remove the screws How to remove the Drain pan Assembly Pan assembly Refrigeration How to remove the Refrigeration assemblyPart name Procedures Remarks How to remove the Multiblade fanFan motor Exploded Views and Parts List Indoor Unit E-Parts AssyAIR-GRILLE
Related manuals
Manual 18 pages 35.13 Kb