York DM 078 manual DM078 6-1/2 TON Side Shot Blower Performance

Page 23

Johnson Controls Unitary Products

TABLE 21: DM078 (6-1/2 TON) SIDE SHOT BLOWER PERFORMANCE

 

 

 

 

 

 

 

 

 

 

 

 

External Static Pressure

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

RPM

BHP

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1900

----

----

----

----

----

----

687

0.69

641

764

0.81

758

839

0.95

884

893

1.18

1097

957

1.34

1252

1013

1.42

1324

1062

1.59

1484

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

----

----

----

----

----

----

697

0.72

676

772

0.84

782

846

1.01

940

900

1.22

1137

963

1.39

1299

1019

1.48

1377

1067

1.65

1541

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2100

----

----

----

----

----

----

707

0.76

712

781

0.87

810

854

1.07

997

907

1.26

1179

970

1.44

1346

1024

1.53

1430

1073

1.71

1599

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2200

----

----

----

608

0.61

572

717

0.80

750

789

0.90

843

861

1.13

1055

913

1.31

1223

976

1.50

1395

1030

1.59

1485

1078

1.78

1656

2300

----

----

----

623

0.66

614

727

0.85

790

798

0.94

880

869

1.19

1113

920

1.36

1269

983

1.55

1444

1035

1.65

1541

1083

1.84

1713

2400

----

----

----

639

0.71

659

736

0.89

832

807

0.99

922

876

1.26

1172

927

1.41

1318

989

1.60

1493

1041

1.71

1597

1088

1.90

1770

2500

602

0.59

550

654

0.76

705

746

0.94

877

815

1.04

968

884

1.32

1232

934

1.47

1369

996

1.66

1544

1046

1.78

1655

1094

1.96

1827

2600

612

0.64

600

669

0.81

755

756

0.99

923

824

1.09

1019

891

1.39

1292

940

1.53

1423

1002

1.71

1595

1051

1.84

1713

1099

2.02

1884

2700

622

0.70

652

684

0.86

806

766

1.04

971

832

1.15

1074

899

1.45

1353

947

1.59

1479

1008

1.77

1647

1057

1.90

1773

1104

2.08

1941

2800

632

0.76

707

699

0.92

860

776

1.10

1022

841

1.22

1133

906

1.52

1414

954

1.65

1537

1015

1.82

1700

1062

1.97

1833

1109

2.14

1999

2900

642

0.82

764

715

0.98

917

786

1.15

1074

850

1.28

1197

914

1.58

1476

960

1.71

1597

1021

1.88

1753

1068

2.03

1894

----

----

----

3000

652

0.88

823

730

1.05

976

795

1.21

1129

858

1.36

1266

921

1.65

1539

967

1.78

1660

1028

1.94

1807

1073

2.10

1956

----

----

----

3100

662

0.95

885

745

1.11

1037

805

1.27

1185

867

1.44

1339

929

1.72

1602

974

1.85

1725

1034

2.00

1862

----

----

----

----

----

----

3200

672

1.02

949

760

1.18

1100

815

1.33

1244

876

1.52

1417

936

1.79

1666

981

1.92

1793

1041

2.06

1918

----

----

----

----

----

----

3300

682

1.09

1016

776

1.25

1166

825

1.40

1305

884

1.61

1499

944

1.86

1731

987

2.00

1862

1047

2.12

1974

----

----

----

----

----

----

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Horsepower Option Required

23

246645-YTG-C-0708

Image 23
Contents Technical Guide Table of Contents Features YTG-C-0708 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Part Number Description Weight AccessoriesYTG-C-0708 Ton York Model Number Nomenclature DM Physical Data DB† DM Capacity RatingsUnit Voltage Limitations Rating Electric Heat Size SeasonalCooling Capacity DM078 6-1/2 TON Unit 2250 Cooling Capacity DM090 7-1/2 TON Unit2550 Cooling Capacity DM102 8-1/2 TON UnitCooling Capacity DM120 10 TON Unit Cooling Capacity DM150 12-1/2 TON Unit MCA FLA Outlet Amps Size Amps Exhaust Model No Supply Pwr Min. Circuit 600 Electric Heat Multipliers240 480DM078 6-1/2 TON Side Shot Blower Performance CFM DM090 7-1/2 TON Side Shot Blower PerformanceDM102 8-1/2 TON Side Shot Blower Performance DM120 10 TON Side Shot Blower Performance DM150 12-1/2 TON Side Shot Blower Performance RPM BHP DM078 6-1/2 TON Down Shot Blower PerformanceDM090 7-1/2 TON Down Shot Blower Performance DM102 8-1/2 TON Down Shot Blower Performance DM120 10 TON Down Shot Blower Performance DM150 12-1/2 TON Down Shot Blower Performance Cooling Only Economizer† ‡ Electric Heat KW† Additional Static Resistance DM078, 120Additional Static Resistance DM090 Electric Heat Minimum Supply AIR CFM Indoor Blower SpecificationsPower Exhaust Specifications Model Location lbs Unit Clearances Point Load WeightUnit Weight Detail aDetail B Detail C Predator Roof Curb DimensionsSunline to Predator Transition Roof Curbs Air Application Cabinet Height Description Model Economizer UsageField Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0708 Description PredatorGeneral GAS Heating Section if Equipped Johnson Controls Unitary Products York Drive Norman, OK Additional Factory Installed Options