REAR DUCT DIMENSIONS

CABINET SIZE

 

DIMENSION

 

“A”

“B”

 

“C”

 

 

50 3/4”

28 1/4

18 1/16

 

28 1/4

42”

27 3/4

12 1/16

 

27 1/2

 

 

DotPlugsReturn

18-1/4

A

 

 

 

246645-YTG-C-0708

18-1/4

SupplyAir

Air

 

B

5-5/32

C

31-11/162-31/32

 

FIGURE 9 - REAR DUCT DIMENSIONS

391/2 or

47 1/2

Outside Air Intake Hood

58 1/4

88 1/4

35 3/4

Relief Hood for

Power Exhaust or

Barometric Relief

26

 

25 3/4

 

 

 

 

 

 

26

 

 

 

 

 

30 1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 10 - DOWNFLOW ECONOMIZER HOOD DETAIL

Johnson Controls Unitary Products

39

Image 39
Contents Technical Guide Table of Contents Features YTG-C-0708 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Part Number Description Weight AccessoriesYTG-C-0708 Ton York Model Number Nomenclature DM Physical Data DB† DM Capacity RatingsUnit Voltage Limitations Rating Electric Heat Size SeasonalCooling Capacity DM078 6-1/2 TON Unit 2250 Cooling Capacity DM090 7-1/2 TON Unit2550 Cooling Capacity DM102 8-1/2 TON UnitCooling Capacity DM120 10 TON Unit Cooling Capacity DM150 12-1/2 TON Unit MCA FLA Outlet Amps Size Amps Exhaust Model No Supply Pwr Min. Circuit 600 Electric Heat Multipliers240 480DM078 6-1/2 TON Side Shot Blower Performance CFM DM090 7-1/2 TON Side Shot Blower PerformanceDM102 8-1/2 TON Side Shot Blower Performance DM120 10 TON Side Shot Blower Performance DM150 12-1/2 TON Side Shot Blower Performance RPM BHP DM078 6-1/2 TON Down Shot Blower PerformanceDM090 7-1/2 TON Down Shot Blower Performance DM102 8-1/2 TON Down Shot Blower Performance DM120 10 TON Down Shot Blower Performance DM150 12-1/2 TON Down Shot Blower Performance Additional Static Resistance DM078, 120 Additional Static Resistance DM090Cooling Only Economizer† ‡ Electric Heat KW† Indoor Blower Specifications Power Exhaust SpecificationsElectric Heat Minimum Supply AIR CFM Model Location lbs Unit Clearances Point Load WeightUnit Weight Detail aDetail B Detail C Predator Roof Curb DimensionsSunline to Predator Transition Roof Curbs Air Application Cabinet Height Description Model Economizer UsageField Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0708 Predator GeneralDescription GAS Heating Section if Equipped Johnson Controls Unitary Products York Drive Norman, OK Additional Factory Installed Options