TABLE 26: DM078 (6-1/2 TON) DOWN SHOT BLOWER PERFORMANCE

CFM

 

 

 

 

 

 

 

 

 

 

External Static Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

 

1.2

 

 

1.4

 

 

1.6

 

 

 

 

 

 

 

RPM

BHP

Watts

RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts RPM BHP Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1900

----

----

----

----

----

----

733

0.75

698

804

0.9

825

881

1.03

963

931

1.21

1124

980

1.37

1279

1019

1.51

1409

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

----

----

----

----

----

----

745

0.8

742

814

0.94

872

885

1.09

1017

939

1.27

1181

987

1.43

1336

1025

1.57

1465

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2100

----

----

----

----

----

----

756

0.85

789

824

0.99

922

889

1.15

1073

946

1.33

1240

993

1.5

1395

1031

1.63

1521

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2200

----

----

----

----

----

----

767

0.9

839

835

1.05

975

894

1.21

1131

954

1.4

1301

1000

1.56

1454

1036

1.69

1578

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2300

----

----

----

720

0.75

699

778

0.96

891

845

1.1

1030

898

1.28

1191

962

1.46

1363

1006

1.63

1515

1042

1.76

1636

2400

----

----

----

732

0.82

763

789

1.01

946

855

1.17

1088

902

1.34

1253

969

1.53

1426

1013

1.69

1577

1047

1.82

1695

2500

----

----

----

743

0.9

828

801

1.08

1003

865

1.23

1148

906

1.41

1317

977

1.6

1491

1019

1.76

1641

1053

1.88

1755

2600

----

----

----

755

0.96

895

812

1.14

1063

875

1.3

1211

910

1.48

1384

985

1.67

1558

1026

1.83

1705

1059

1.95

1816

2700

728

0.76

709

767

1.03

964

823

1.21

1125

886

1.37

1276

914

1.56

1452

992

1.75

1627

1032

1.9

1771

1064

2.01

1878

2800

739

0.86

801

778

1.11

1035

834

1.28

1190

896

1.44

1344

918

1.63

1523

1000

1.82

1697

1039

1.97

1838

----

----

----

2900

750

0.96

894

790

1.19

1107

846

1.35

1257

906

1.52

1414

923

1.71

1596

1008

1.9

1769

1045

2.04

1906

----

----

----

3000

761

1.06

987

801

1.27

1182

857

1.42

1327

916

1.59

1487

927

1.79

1671

1015

1.98

1842

----

----

----

----

----

----

3100

772

1.16

1080

813

1.35

1258

868

1.5

1400

926

1.68

1562

931

1.87

1748

1023

2.06

1917

----

----

----

----

----

----

3200

784

1.26

1175

825

1.43

1336

879

1.58

1475

937

1.76

1640

935

1.96

1827

----

----

----

----

----

----

----

----

----

3300

795

1.36

1269

836

1.52

1417

890

1.67

1552

947

1.85

1721

939

2.05

1908

----

----

----

----

----

----

----

----

----

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Horsepower Option Required

Motor Efficiency 0.8

Std HP Motor 1.5

246645-YTG-C-0708

Johnson Controls Unitary Products

Image 28
Contents Technical Guide Table of Contents Features YTG-C-0708 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Accessories Part Number Description WeightYTG-C-0708 Ton York Model Number Nomenclature DM Physical Data DM Capacity Ratings Unit Voltage LimitationsRating Electric Heat Size Seasonal DB†Cooling Capacity DM078 6-1/2 TON Unit Cooling Capacity DM090 7-1/2 TON Unit 2250Cooling Capacity DM102 8-1/2 TON Unit 2550Cooling Capacity DM120 10 TON Unit Cooling Capacity DM150 12-1/2 TON Unit MCA FLA Outlet Amps Size Amps Exhaust Model No Supply Pwr Min. Circuit Electric Heat Multipliers 240480 600DM078 6-1/2 TON Side Shot Blower Performance DM090 7-1/2 TON Side Shot Blower Performance CFMDM102 8-1/2 TON Side Shot Blower Performance DM120 10 TON Side Shot Blower Performance DM150 12-1/2 TON Side Shot Blower Performance DM078 6-1/2 TON Down Shot Blower Performance RPM BHPDM090 7-1/2 TON Down Shot Blower Performance DM102 8-1/2 TON Down Shot Blower Performance DM120 10 TON Down Shot Blower Performance DM150 12-1/2 TON Down Shot Blower Performance Additional Static Resistance DM090 Additional Static Resistance DM078, 120Cooling Only Economizer† ‡ Electric Heat KW† Power Exhaust Specifications Indoor Blower SpecificationsElectric Heat Minimum Supply AIR CFM Model Location lbs Point Load Weight Unit WeightDetail a Unit ClearancesPredator Roof Curb Dimensions Detail B Detail CSunline to Predator Transition Roof Curbs Air Economizer Usage Application Cabinet Height Description ModelField Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0708 General PredatorDescription GAS Heating Section if Equipped Additional Factory Installed Options Johnson Controls Unitary Products York Drive Norman, OK