York DM 078 manual Model Location lbs

Page 35

246645-YTG-C-0708

LEFT

A

FRONT

BC

X

Y

 

LEFT

FRONT

 

Unit Model Number

X

Y

 

 

 

DM078

47 1/2

25 1/2

 

 

 

DM090

38

23

 

 

 

DM102

38

23

 

 

 

DM120

47 1/2

25 1/2

 

 

 

DM150

47 1/2

25 1/2

 

 

 

D

FIGURE 2 - UNIT 4 POINT LOAD TABLE 36: 4 POINT LOAD WEIGHT

FIGURE 3 - UNIT CENTER OF GRAVITY

Model

 

Location (lbs.)

 

 

 

 

 

A

B

C

D

 

 

 

 

 

 

DM078

228

195

285

333

DM090

192

143

224

301

 

 

 

 

 

DM102

195

146

228

306

 

 

 

 

 

DM120

245

209

305

357

 

 

 

 

 

DM150

262

224

327

382

LEFT

AB

FRONT

CD

E

F

FIGURE 4 - UNIT 6 POINT LOAD

Johnson Controls Unitary Products

35

Image 35
Contents Technical Guide Table of Contents Features YTG-C-0708 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Part Number Description Weight AccessoriesYTG-C-0708 Ton York Model Number Nomenclature DM Physical Data DB† DM Capacity RatingsUnit Voltage Limitations Rating Electric Heat Size SeasonalCooling Capacity DM078 6-1/2 TON Unit 2250 Cooling Capacity DM090 7-1/2 TON Unit2550 Cooling Capacity DM102 8-1/2 TON UnitCooling Capacity DM120 10 TON Unit Cooling Capacity DM150 12-1/2 TON Unit MCA FLA Outlet Amps Size Amps Exhaust Model No Supply Pwr Min. Circuit 600 Electric Heat Multipliers240 480DM078 6-1/2 TON Side Shot Blower Performance CFM DM090 7-1/2 TON Side Shot Blower PerformanceDM102 8-1/2 TON Side Shot Blower Performance DM120 10 TON Side Shot Blower Performance DM150 12-1/2 TON Side Shot Blower Performance RPM BHP DM078 6-1/2 TON Down Shot Blower PerformanceDM090 7-1/2 TON Down Shot Blower Performance DM102 8-1/2 TON Down Shot Blower Performance DM120 10 TON Down Shot Blower Performance DM150 12-1/2 TON Down Shot Blower Performance Cooling Only Economizer† ‡ Electric Heat KW† Additional Static Resistance DM078, 120Additional Static Resistance DM090 Electric Heat Minimum Supply AIR CFM Indoor Blower SpecificationsPower Exhaust Specifications Model Location lbs Unit Clearances Point Load WeightUnit Weight Detail aDetail B Detail C Predator Roof Curb DimensionsSunline to Predator Transition Roof Curbs Air Application Cabinet Height Description Model Economizer UsageField Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0708 Description PredatorGeneral GAS Heating Section if Equipped Johnson Controls Unitary Products York Drive Norman, OK Additional Factory Installed Options