8.Install the heatsink ("Heatsink" on page 30).
9.Install all components removed from the failed system board.
IMPORTANT: Install all components with the same configuration that was used on the failed system board.
After you replace the system board, you must
1.During the server startup sequence, press the F9 key to access RBSU.
2.Select the System Options menu.
3.Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option should only be used by qualified service personnel. This value should always match the serial number sticker located on the chassis.
4.Press the Enter key to clear the warning.
5.Enter the serial number and press the Enter key.
6.Select Product ID.
7.Enter the product ID and press the Enter key.
8.Press the Esc key to close the menu.
9.Press the Esc key to exit RBSU.
10.Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
System battery
If the server blade no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the