Toshiba A09-01P manual Function Code Access, Display Explanation

Page 22

Display Explanation (cont.)

 

 

 

 

19: TIMER

 

 

 

 

 

 

 

Display

 

 

Description

 

 

 

 

 

Clock: Displays the current time

 

 

 

 

(AM or PM).

 

 

 

 

 

 

 

 

 

Displays days of the week (Sunday

 

 

 

 

to Saturday).

 

 

 

 

 

 

 

 

 

Lights when the NIGHT button is

 

 

 

 

pressed and goes out when the

 

 

 

 

button is pressed again.

 

 

 

 

Lights when night time quiet

 

 

 

 

operation is set.

 

 

 

 

 

 

 

 

 

Indicates scheduled operation 1

 

 

 

 

status (including setting time).

 

 

 

 

 

 

 

 

 

Displays the scheduled operation

 

 

 

 

step when the scheduled operation

 

 

 

 

STEP1-5 program is set.

 

 

 

 

Lights during time setting and

 

 

 

 

scheduled operation setting.

 

 

 

 

 

 

 

 

 

 

Quick Reference Guide - Page 22

 

 

 

 

 

 

 

 

 

 

21: OPERATION

 

 

Display

 

 

Description

 

 

 

 

 

Lights while internal pump (P1) or

 

 

 

 

external pump (P2) is driven.

 

 

 

 

Lights during backup operation only by

 

 

 

 

 

 

 

 

the heater.

 

 

 

 

Lights when the unit enters the data set

 

 

 

 

 

 

 

 

mode and goes out when the unit exits

 

 

 

 

the data set mode.

 

 

 

 

Lights when the unit enters the service

 

 

 

 

mode and goes out when the unit exits

 

 

 

 

the service mode.

 

 

 

 

Lights when an error occurs and goes

 

 

 

 

out when the error is cleared.

 

 

 

 

Lights for two seconds when settings are

 

 

 

 

 

 

 

 

completed.

 

 

 

 

Lights for two seconds when settings

 

 

 

 

 

 

 

 

failed.

 

 

 

 

 

 

Function Code Access

Set function codes for various operation modes, input using the remote controller. There are 2 types of settings:-

1)Hydro Unit function code setting.

2)Remote controller function code setting.

Setting procedure for Hydro Unit function code

1. Press the TEST + SET + SELECT buttons

for four seconds or more to enter the hydro unit function code setting mode.

2.Set the function code number with the TEMP. buttons (CODE No.: 01 to 91).

3.Set data (DATA) with the TIME buttons .

4.Press the SET button to confirm the settings.

5.The CL button is enabled only before the SET button is pressed and the function code is changed.

6.Press the TEST button to finish the settings.

Setting procedure for Remote Controller function code

1.Press the TEST + CL + TEMP. ▼ buttons for four seconds or more to enter the remote controller function code setting mode.

2.Set the function code number with the TEMP. buttons (CODE No.: 01 to 13).

3.Set data (DATA) with the TIME buttons .

4.Press the SET button to determine the settings.

5.The CL button is enabled only before the SET button is

pressed and the function code is changed.

6. Press the TEST button to end the settings.

Image 22
Contents AIR to Water Heat Pump Estia Hot Water Cylinder EU Estia SystemEstia Hot Water Cylinder UK Purpose Toshiba Supply Part name Model code Options required for each function14 kW Procure locallyInstallation Examples Space Cooling and Space Heating with Domestic Hot WaterZone Space Heating with Domestic Hot Water Hydro Unit Exploded View Refrigerant Pipe Lengths and Height Refrigeration and Water Cycle Diagrams Hydro UnitRefrigerant Piping Minimum Pipe LengthOutdoor Unit HWS-802H-E HWS-1102H-E, 1402H-E Water Piping Limitations Water PipingWater Connections Piping to hot water tank optionExample ActionWater quality Pump operation / configurationWater charging Piping insulationElectrical Connections Box layout Terminal Block ConnectionsPower Lines Schematic Control Lines Schematic Wiring specification control line Electrical supply / cable specificationsWiring specifications power line Control parts specificationsElectrical connection to hydro unit Input line specificationsEarthing arrangements Outdoor unit to hydro unit electrical connectionElectrical connection for external booster heater Electrical connection for external additional pump P2Way valve diverter connection Required Valve SpecificationWay valve for cooling connection Diverter Valve Description SW13-1Way mixing valve connection Required Actuator SpecificationElectrical Connection Hot Water Cylinder temperature Sensor Hot water cylinder connection optionalSetting DIP Switches on the Board in the Hydro Unit Hydro Unit Remote Control Buttons and FunctionsDisplay Description Display ExplanationZONE1, ZONE2 Display HOT Water DescriptionSetting procedure for Remote Controller function code Function Code AccessSetting procedure for Hydro Unit function code Display ExplanationMain setting items Main setting item Function Code ListFunction Setting for cooling Settings by PurposeSettings when hot water supply function is not used Settings for hot water supplySettings for 2-zone temperature control Test RunSymptom Possible cause Sensor Temperature Monitoring FunctionFault Symptoms Code No Location IndicationAlarm Indications Alarm Indications Outdoor Alarm indicationAlarm Main failure part Description Indication Outdoor Fault Diagnosis Check of the current abnormal status

A09-01P specifications

The Toshiba A09-01P is a cutting-edge air conditioning unit that has garnered attention for its sleek design and advanced technology. This model is well-suited for both residential and commercial spaces, providing efficient cooling and heating, which makes it a versatile choice for year-round comfort.

One of the standout features of the A09-01P is its energy efficiency, marked by its high SEER (Seasonal Energy Efficiency Ratio) rating. This means that it uses less electricity compared to traditional models, which is beneficial not only for the environment but also for reducing utility bills. The unit employs inverter technology, which allows the compressor to adjust its output based on the cooling demand. This results in more consistent temperatures and minimizes energy waste.

The Toshiba A09-01P is also equipped with a multi-stage air purification system. This advanced filtration process includes a pre-filter, a HEPA filter, and an activated carbon filter. The pre-filter captures larger particles, while the HEPA filter can remove up to 99.97% of microscopic allergens and pollutants. The activated carbon filter helps to eliminate odors, ensuring that the air quality remains fresh and clean.

In terms of user convenience, the device comes with a smart remote control that allows users to adjust settings without getting up. It features programmable timers and multiple modes, including auto, cool, and dry modes, aiding users in customizing their experience according to specific needs.

The unit's compact design allows for installation in tighter spaces, making it ideal for urban environments where real estate is at a premium. The quiet operation of the A09-01P is another significant advantage, ensuring that it runs unobtrusively in the background, making it perfect for bedrooms or offices.

Furthermore, Toshiba has integrated smart technology into the A09-01P, allowing it to be controlled via smartphone apps. This feature adds an extra layer of convenience, enabling users to manage their indoor climate even when they are away from home.

Overall, the Toshiba A09-01P stands out in the air conditioning market due to its combination of energy efficiency, advanced filtration, and user-friendly features, making it a wise investment for any space requiring climate control.