Toshiba A09-01P manual Hydro Unit Remote Control, Buttons and Functions

Page 20

Quick Reference Guide - Page 20

Hydro Unit Remote Control

Buttons and Functions

1. TEMP. button:

Changes the set temperature for

10. NIGHT button:

Controls the night set back

 

 

 

each operation mode (ZONE1/2 hot

 

 

 

operation.

 

water) by 1°C step.

 

 

 

 

 

 

 

 

2. SCHEDULE

 

11. AUTO TEMP.

Switches setting temperature

button:

Sets the current time and

button:

automatically according to outside

 

 

temperature. (Pressing this button

 

scheduled weekly operation.

 

 

 

long changes the mode to data

 

 

 

 

 

 

setting mode).

3. TIME button:

Changes time for current time

12. OPERATE

 

 

setting and scheduled weekly

MODE button:

Selects ZONE1/2 operation mode

 

operation setting with ▼ and ▲

 

(heating or cooling).

 

buttons.

 

 

4. SET button:

Determines the entered current

13. ZONE1, 2

 

 

button:

Turns on/off the zone (floor

 

time setting and scheduled weekly

 

 

heating/radiator/FCU) operation.

 

operation setting.

 

 

 

 

 

 

 

 

5. CL button:

 

14. ANTI BACTERIA

Regularly increases the hot water

 

Clears settings for the current time

button:

temperature in the tank for

 

 

sterilization. (Pressing this button

 

and scheduled weekly operation.

 

 

 

long changes the mode to data

 

 

 

 

 

 

setting mode).

6. DAY button:

Sets days of the week for current

15. HOT WATER

 

 

BOOST button:

Boosts boiling when high tapping

 

time setting and scheduled weekly

 

 

temperature is required temporarily.

 

operation setting.

 

 

 

 

 

 

 

 

7. STEP button:

Specifies switching STEP number

16. HOT WATER

 

 

button:

Turns on/off hot water operation.

 

in a day for weekly schedule.

 

 

 

 

 

 

 

 

8. TEST button:

 

17. SELECT button:

Selects an operation mode when

 

Used for test run or service.

 

changing the set temperature of

 

 

 

each operation mode.

 

 

 

 

9. FROST

Controls minimum operation for

 

 

PROTECTION

 

 

unused period (going out,

 

 

button:

 

 

absence,etc.) for anti freezing.

 

 

 

 

 

 

 

 

 

NOTE

Some functions are not provided depending on the system specification in use.

Image 20
Contents AIR to Water Heat Pump Estia Hot Water Cylinder UK Estia SystemEstia Hot Water Cylinder EU Options required for each function 14 kWPurpose Toshiba Supply Part name Model code Procure locallyInstallation Examples Space Cooling and Space Heating with Domestic Hot WaterZone Space Heating with Domestic Hot Water Hydro Unit Exploded View Refrigeration and Water Cycle Diagrams Hydro Unit Refrigerant PipingRefrigerant Pipe Lengths and Height Minimum Pipe LengthOutdoor Unit HWS-802H-E HWS-1102H-E, 1402H-E Water Piping Water ConnectionsWater Piping Limitations Piping to hot water tank optionExample ActionPump operation / configuration Water chargingWater quality Piping insulationElectrical Connections Box layout Terminal Block ConnectionsPower Lines Schematic Control Lines Schematic Electrical supply / cable specifications Wiring specifications power lineWiring specification control line Control parts specificationsInput line specifications Earthing arrangementsElectrical connection to hydro unit Outdoor unit to hydro unit electrical connectionElectrical connection for external booster heater Electrical connection for external additional pump P2Required Valve Specification Way valve for cooling connectionWay valve diverter connection Diverter Valve Description SW13-1Required Actuator Specification Electrical Connection Hot Water Cylinder temperature SensorWay mixing valve connection Hot water cylinder connection optionalSetting DIP Switches on the Board in the Hydro Unit Hydro Unit Remote Control Buttons and FunctionsDisplay Explanation ZONE1, ZONE2Display Description Display HOT Water DescriptionFunction Code Access Setting procedure for Hydro Unit function codeSetting procedure for Remote Controller function code Display ExplanationMain setting items Main setting item Function Code ListFunction Settings by Purpose Settings when hot water supply function is not usedSetting for cooling Settings for hot water supplySettings for 2-zone temperature control Test RunSensor Temperature Monitoring Function Fault SymptomsSymptom Possible cause Code No Location IndicationAlarm Indications Alarm Main failure part Description Indication Outdoor Alarm indicationAlarm Indications Outdoor Fault Diagnosis Check of the current abnormal status

A09-01P specifications

The Toshiba A09-01P is a cutting-edge air conditioning unit that has garnered attention for its sleek design and advanced technology. This model is well-suited for both residential and commercial spaces, providing efficient cooling and heating, which makes it a versatile choice for year-round comfort.

One of the standout features of the A09-01P is its energy efficiency, marked by its high SEER (Seasonal Energy Efficiency Ratio) rating. This means that it uses less electricity compared to traditional models, which is beneficial not only for the environment but also for reducing utility bills. The unit employs inverter technology, which allows the compressor to adjust its output based on the cooling demand. This results in more consistent temperatures and minimizes energy waste.

The Toshiba A09-01P is also equipped with a multi-stage air purification system. This advanced filtration process includes a pre-filter, a HEPA filter, and an activated carbon filter. The pre-filter captures larger particles, while the HEPA filter can remove up to 99.97% of microscopic allergens and pollutants. The activated carbon filter helps to eliminate odors, ensuring that the air quality remains fresh and clean.

In terms of user convenience, the device comes with a smart remote control that allows users to adjust settings without getting up. It features programmable timers and multiple modes, including auto, cool, and dry modes, aiding users in customizing their experience according to specific needs.

The unit's compact design allows for installation in tighter spaces, making it ideal for urban environments where real estate is at a premium. The quiet operation of the A09-01P is another significant advantage, ensuring that it runs unobtrusively in the background, making it perfect for bedrooms or offices.

Furthermore, Toshiba has integrated smart technology into the A09-01P, allowing it to be controlled via smartphone apps. This feature adds an extra layer of convenience, enabling users to manage their indoor climate even when they are away from home.

Overall, the Toshiba A09-01P stands out in the air conditioning market due to its combination of energy efficiency, advanced filtration, and user-friendly features, making it a wise investment for any space requiring climate control.