Omega Vehicle Security FPU500 manual Parts of the Pump

Page 15

Setting Up the Pump(s)

3

 

 

1.Refer to Figure 3-1. Make sure the pump is in the closed position.

2.Refer to Figure 3-2 and Figure A. Place the blade of a flathead screwdriver in the groove of the Rotor Shaft (5). Rotate the Rotor Shaft until its back tab slips into the groove of the motor shaft. Do not try to force the pump onto the motor until you perform Step #3.

3.Refer to Figure 3-3 and Figure A. Swivel the pump back and forth slightly to align the holes on the back of the base (8) with the alignment pins on the face of the motor. Press the pump base up against the face of the motor.

4.Refer to Figure 3-4. With the pump and motor aligned, insert the mounting screws through the mounting holes in the pump, until they make contact with the threaded mounting holes in the face of the motor.

5.Tighten the screws fully with a 964 (M3.5) allen wrench.

Parts of the Pump

8

(Base)

5 (Rotor Shaft)

Figure A

3-3

Image 15
Contents User’s Guide Servicing North America From the Technical Library Peristaltic Pump Index Index Features IntroductionDescription Introduction Parts of the Pump Overall View of the PumpDescription Function View of the Left Side Left Side of the PumpView of the Right Side Right Side of the PumpParts of the Pump Setting Up the Pumps IntroductionRequired Hardware Attaching a Single Pump Directly to the Motor Attaching the PumpParts of the Pump Stacking Two Pumps onto One Motor Figure B Attaching a Single Pump to an Adapter Plate Mounting the adapter plate to the motor refer to Figure Using Your Own Adapter Plate Setting Up the Pumps Tubing Information Selecting TubingTubing Life Tubing Information Operating the Pump Opening the Stator Loading the TubingFigure D 5a. Inlet and Outlet Flow Operating the Pump5b. Inlet and Outlet Flow Adjusting the Clamp ScrewTurn the pump motor off Operating the Pump Maintenance Shows the exploded view of the pump Replacing the Rotor Assembly Part Number FPU500-RAMaintenance Maintenance Problem Solution Troubleshooting GuideProblem Check motor fuse Troubleshooting Guide Design Considerations Design SolutionTechnical Details Theory of OperationStacking More than Two Pumps Specifications ⁄16 ⁄32 132 540 1140 1800 2280 210 Average Flow Rates Cont’d Variances in Normalized Flow Rate mL per RevolutionTubing Average Average Tubing LifeAverage Flow Rates for Viscous Liquids Average Tubing Life ContdSpecifications Spare Parts and Accessories Spare PartsPart Number Description Viton Peristatic Pump Motor 10-4 WARRANTY/DISCLAIMER Shop online at omega.com