Omega Vehicle Security FPU500 manual Loading the Tubing, Opening the Stator

Page 25

5Operating the Pump

5.2 Loading the Tubing

NOTE

Before you load the tubing in the pump, make sure that power to the motor is turned off and that the rotor has come to a complete stop. The rotor is partially exposed when the pump is in the open position.

Follow this procedure (refer to Figures 5-1 through 5-4 and Figure D):

Figure 5-1. Opening the Stator

Figure 5-2. Loading the Tubing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5-3. Closing the Stator

Figure 5-4. Adjusting the Clamp Screw

5-2

Image 25
Contents User’s Guide Servicing North America From the Technical Library Peristaltic Pump Index Index Introduction FeaturesDescription Introduction Overall View of the Pump Parts of the PumpDescription Function View of the Left Side Left Side of the PumpView of the Right Side Right Side of the PumpParts of the Pump Introduction Setting Up the PumpsRequired Hardware Attaching a Single Pump Directly to the Motor Attaching the PumpParts of the Pump Stacking Two Pumps onto One Motor Figure B Attaching a Single Pump to an Adapter Plate Mounting the adapter plate to the motor refer to Figure Using Your Own Adapter Plate Setting Up the Pumps Selecting Tubing Tubing InformationTubing Life Tubing Information Operating the Pump Opening the Stator Loading the TubingFigure D 5a. Inlet and Outlet Flow Operating the Pump5b. Inlet and Outlet Flow Adjusting the Clamp ScrewTurn the pump motor off Operating the Pump Maintenance Shows the exploded view of the pump Replacing the Rotor Assembly Part Number FPU500-RAMaintenance Maintenance Problem Solution Troubleshooting GuideProblem Check motor fuse Troubleshooting Guide Technical Details Design SolutionTheory of Operation Design ConsiderationsStacking More than Two Pumps Specifications ⁄16 ⁄32 132 540 1140 1800 2280 210 Average Flow Rates Cont’d Variances in Normalized Flow Rate mL per RevolutionTubing Average Average Tubing LifeAverage Flow Rates for Viscous Liquids Average Tubing Life ContdSpecifications Spare Parts Spare Parts and AccessoriesPart Number Description Viton Peristatic Pump Motor 10-4 WARRANTY/DISCLAIMER Shop online at omega.com