Omega Vehicle Security FPU500 manual Attaching a Single Pump to an Adapter Plate

Page 18

3Setting Up the Pump(s)

3.3.3 Attaching a Single Pump to an Adapter Plate

Refer to Figures 3-8 through 3-11 and Figure C.

ALIGNMENT PINS

MOTOR SHAFT

THREADED

HOLES

TO MOUNT

ADAPTER

PLATE TO

VENDOR

MOTOR (4X)

ALIGNMENT

PINS FOR

PUMP (2X)

MOUNTING

HOLES

VENDOR

MOTOR

ADAPTER PLATE

CLEARANCE HOLES

FOR VENDOR MOTOR

ALIGNMENT PINS (2X)

Figure 3-8. Mounting the Adapter Plate Figure 3-9. Pump in Closed Position

TOP ALIGNMENT

PIN

FACE OF

 

MOTOR

MOUNTING

BOTTOM

HOLES

 

ALIGNMENT PIN

 

ROTOR SHAFT

ADAPTER

 

PLATE

FLAT HEAD

SCREWDRIVER

Figure 3-10. Aligning the Pump with the Plate

STANDARD

MOUNTING

SCREWS

Figure 3-11. Securing the Pump to

the Plate

3-6

Image 18
Contents User’s Guide Servicing North America From the Technical Library Peristaltic Pump Index Index Features IntroductionDescription Introduction Parts of the Pump Overall View of the PumpDescription Function Left Side of the Pump View of the Left SideRight Side of the Pump View of the Right SideParts of the Pump Setting Up the Pumps IntroductionRequired Hardware Attaching the Pump Attaching a Single Pump Directly to the MotorParts of the Pump Stacking Two Pumps onto One Motor Figure B Attaching a Single Pump to an Adapter Plate Mounting the adapter plate to the motor refer to Figure Using Your Own Adapter Plate Setting Up the Pumps Tubing Information Selecting TubingTubing Life Tubing Information Operating the Pump Loading the Tubing Opening the StatorFigure D Operating the Pump 5a. Inlet and Outlet FlowAdjusting the Clamp Screw 5b. Inlet and Outlet FlowTurn the pump motor off Operating the Pump Maintenance Replacing the Rotor Assembly Part Number FPU500-RA Shows the exploded view of the pumpMaintenance Maintenance Troubleshooting Guide Problem SolutionProblem Check motor fuse Troubleshooting Guide Theory of Operation Design SolutionTechnical Details Design ConsiderationsStacking More than Two Pumps Specifications ⁄16 ⁄32 132 540 1140 1800 2280 210 Variances in Normalized Flow Rate mL per Revolution Average Flow Rates Cont’dAverage Tubing Life Tubing AverageAverage Tubing Life Contd Average Flow Rates for Viscous LiquidsSpecifications Spare Parts and Accessories Spare PartsPart Number Description Viton Peristatic Pump Motor 10-4 WARRANTY/DISCLAIMER Shop online at omega.com