Omega Vehicle Security FPU500 manual Check motor fuse

Page 37

 

 

 

Troubleshooting Guide

7

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

Solution

 

 

 

Motor will not turn

1.

Make sure the tubing is loaded

 

 

 

 

 

properly. The tubing should be

 

 

 

 

 

centered in the middle of the rollers.

 

 

 

Reload if necessary.

 

 

 

 

2.

Check to see if the motor is turned

 

 

 

 

 

on.

 

 

 

 

3.

Check motor fuse.

 

 

 

 

 

 

 

 

Motor will not turn – overcurrent condition

1.Make sure the tubing is loaded properly. The tubing should be centered in the middle of the rollers.

2.Make sure the tubing wall thickness is correct (refer to Table 9-1).

3.The tubing durometer may be too high for the pump (refer to Chapter 9).

4.The tubing may be caught on the bottom roller. Reposition the roller slightly and load the tubing again.

The pump will not stay on the motor

1.The pump is not properly mounted to the motor. Refer to Section 3.

2.The mounting screws are loose. Tighten the screws, if necessary.

7-3

Image 37
Contents User’s Guide Servicing North America From the Technical Library Peristaltic Pump Index Index Introduction FeaturesDescription Introduction Overall View of the Pump Parts of the PumpDescription Function View of the Left Side Left Side of the PumpView of the Right Side Right Side of the PumpParts of the Pump Introduction Setting Up the PumpsRequired Hardware Attaching a Single Pump Directly to the Motor Attaching the PumpParts of the Pump Stacking Two Pumps onto One Motor Figure B Attaching a Single Pump to an Adapter Plate Mounting the adapter plate to the motor refer to Figure Using Your Own Adapter Plate Setting Up the Pumps Selecting Tubing Tubing InformationTubing Life Tubing Information Operating the Pump Opening the Stator Loading the TubingFigure D 5a. Inlet and Outlet Flow Operating the Pump5b. Inlet and Outlet Flow Adjusting the Clamp ScrewTurn the pump motor off Operating the Pump Maintenance Shows the exploded view of the pump Replacing the Rotor Assembly Part Number FPU500-RAMaintenance Maintenance Problem Solution Troubleshooting GuideProblem Check motor fuse Troubleshooting Guide Technical Details Design SolutionTheory of Operation Design ConsiderationsStacking More than Two Pumps Specifications ⁄16 ⁄32 132 540 1140 1800 2280 210 Average Flow Rates Cont’d Variances in Normalized Flow Rate mL per RevolutionTubing Average Average Tubing LifeAverage Flow Rates for Viscous Liquids Average Tubing Life ContdSpecifications Spare Parts Spare Parts and AccessoriesPart Number Description Viton Peristatic Pump Motor 10-4 WARRANTY/DISCLAIMER Shop online at omega.com