Lenox 506637-01 Detail a Outside Unit Placement, Placement, Slab Mounting and Stabilizing Unit

Page 8

DETAIL A Outside Unit Placement

Install unit away from windows.

TWO 90° ELBOWS INSTALLED IN LINE SET WILL

REDUCE LINE SET VIBRATION.

DETAIL B

Install unit level or, if on a slope, maintain slope tolerance of two (2) degrees (or two inches per five feet [50 mm per 1.5 m]) away from building structure.

BUILDING

STRUCTURE

MOUNTING

SLAB

GROUND LEVEL

DETAIL C Elevated Slab Mounting using Feet Extenders

STABILIZING UNIT ON UNEVEN SURFACES

DETAIL D

BASE

LEG DETAIL

#10 1/2" LONG SELF−DRILLING SHEET METAL SCREWS

STABILIZING BRACKET (18 GAUGE

METAL

REQUIRED)

#10 1−1/4" LONG HEX HD SCREW AND FLAT WASHER

Concrete slab plastic anchors (hole drill 1/4")

Wood or plastic slab drill 1/8")

DETAIL E op Mounting

Stabilizing bracket (18 gauge metal right angle as exampled below.

COIL

BASE PAN

CORNER POST

2" (50.8MM) SCH 40 FEMALE THREADED ADAPTER

2" (50.8MM) SCH 40 MALE THREADED ADAPTER

Use additional 2" SCH 40 male threaded adapters which can be threaded into the female threaded adapters to make additional adjustments to the level of the unit.

MINIMUM ONE

PER SIDE

SAME FASTENERS AS

FOR EXTRA

SLAB SIDE MOUNTING.

STABILITY

 

One bracket per side (minimum). For extra stability, two brackets per side, two inches (51mm) from each corner.

IMPORTANT To help stabilize an outdoor unit, some installations may require strapping the unit to the pad using brackets and anchors commonly available in the marketplace.

Figure 4. Placement, Slab Mounting and Stabilizing Unit

Page 8

506637−01 11/10

Image 8
Contents Table of Contents GeneralShipping and Packing List AIR ConditionerUnit Dimensions − Inches mm Model Number Identification XXX 230Side View TOP ViewControl Panel Plumbing and Switches ComponentsTypical Unit Parts Arrangement Operating Gauge Set and Service Valves Using Manifold Gauge SETOperating Service Valves Torque RequirementsOperating Angle Type Service Valve Operating Ball Type Service ValveTo Access Service Port Reinstall Stem CapRecovering Refrigerant from Existing System Refrigerant from System 1DISCONNECT PowerRecovering Refrigerant 2CONNECT Manifold Gauge SETNew Outdoor Unit Placement Clearance on ALL SidesPositioning Considerations Placing Unit on SlabDetail a Outside Unit Placement Placement, Slab Mounting and Stabilizing UnitRemoving and Installing Panels Louvered Panel InstallationRoof Mounting Louvered Panel RemovalRefrigerant Line Set New or Replacement Line SetRefrigerant Line SET Refrigerant Line SET From Vertical to Horizontal Refrigerant Line SET Alling Horizontal RunsBrazing Connections Brazing Procedures 1CUT and DeburWrap Service Valves Flow Nitrogen6BRAZE Line SET 7PREPARATION for Next StepInstalling Indoor Expansion Valve Flushing Line Set and Indoor CoilInstalling Indoor Metering Device Indoor Expansion Valve InstallationSensing Bulb Installation Equalizer Line InstallationLeak Test Line Set and Indoor Coil Leak TestEvacuating Line Set and Indoor Coil Evacuating SystemSize Circuit and Install Disconnect 2INSTALL ThermostatElectrical 24VAC TransformerTypical Unit Wiring Diagram Servicing Units Delivered Void of Charge Unit Start−UpConnections for Testing and Charging When to CHARGE?System Refrigerant RequirementsCalculating System Charge for Outdoor Unit Void of Charge Checking AIR Flow AT Indoor CoilWeigh in Charging Method Above BelowSystem Operation TWO−STAGE CompressorMaintenance Unit ComponentsIndoor Unit Indoor CoilHomeowner Start−Up and Performance Checklist TemperatureCompressor Outdoor Unit FAN Motor

Elite Series X16 Air Conditioner Units, 506637-01 specifications

The Lenox 506637-01, Elite Series X16 Air Conditioner is a top-tier cooling solution that stands out in the residential HVAC market. Known for its impressive energy efficiency and advanced features, this unit is designed to provide homeowners with exceptional comfort while also keeping energy bills in check.

One of the main highlights of the Elite Series X16 is its SEER rating, which stands at an impressive 16. This makes it one of the most energy-efficient air conditioning systems available, ensuring that it operates effectively without consuming excessive power. By converting less energy into cooling, homeowners can enjoy lower utility bills and a reduced carbon footprint.

The X16 model features a two-stage cooling system, which allows for better humidity control and more even temperature distribution throughout the home. Unlike standard single-stage units that operate at full capacity at all times, the two-stage system enables the air conditioner to run at a lower, more efficient speed for the majority of its operation, only ramping up when additional cooling is needed. This not only enhances comfort but also extends the lifespan of the unit.

Incorporating advanced technology, the Elite Series X16 utilizes a high-efficiency scroll compressor and innovative airflow design. This results in quieter operation, providing a peaceful indoor environment. The noise levels are minimal, making it suitable for nighttime use or for homes where noise might be a concern.

The air conditioner is built with durability in mind, featuring a robust cabinet that protects against the elements and potential wear and tear over time. Its louvered design provides additional protection for critical components, ensuring longevity and consistent performance.

Furthermore, the X16 is compatible with smart thermostats and home automation systems, allowing homeowners to optimize their cooling schedules remotely. This connectivity helps users make informed decisions about energy usage, further enhancing efficiency while providing ultimate control over home comfort.

In summary, the Lenox 506637-01, Elite Series X16 Air Conditioner provides an excellent blend of energy efficiency, advanced technology, and a focus on comfort and durability. With its two-stage cooling system, high SEER rating, and quiet operation, it is an ideal choice for those seeking a reliable, high-performance cooling solution for their homes.