SAFE INSTALLATION, USE AND SERVICE

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.

Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

 

 

 

 

DANGER indicates an imminently

 

 

DANGER

 

 

 

 

 

 

 

hazardous situation which, if not avoided,

 

 

 

 

could result in death or injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING indicates a potentially hazardous

 

 

WARNING

 

 

 

 

 

 

 

situation which, if not avoided, could result

 

 

 

 

in death or injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION indicates a potentially hazardous

 

 

CAUTION

 

 

 

 

 

 

 

situation which, if not avoided, may result

 

 

 

 

in minor or moderate injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION used without the safety alert

 

 

 

 

 

CAUTION

 

symbol indicates a potentially hazardous

 

 

situation which, if not avoided, could result

 

 

 

 

in property damage.

 

 

 

 

 

 

 

 

 

All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.

IMPORTANT DEFINITIONS

Maytag Customer Service Center: The Maytag Customer Service Center has the ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The Service Center also has a thorough understanding of this instruction manual, and is able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.

Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.

2

Image 2
Contents Series Twelve Safe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsTo Install or Operate the Water Heater Additional Tools Needed When Sweat Soldering Accessories and Tools NeededAccessories ToolsInstructions for Installation Removing the Old Water HeaterTypical Installation Thermostat Pilot & Main BurnerMixing Valve Usage Locating the NEW Water Heater Facts to Consider About the LocationCombustion Air and Ventilation VentingclearancesVenting Through Roof Clearances Insulation Blankets ALL AIR from Inside BuildingsWater Piping Valve and Pipe Insulation Temperature-Pressure Relief Valve Wiring Filling the Water HeaterWiring Diagram USE Without Power CordGallon 70,000 and 75,000 BTU/HR Models only VentingVenting Throughan Outside Wall Optional 4 Vent Piping ALL 40 and 50 Gallon 40,000 BTU/HR Models onlyVenting System Example Installations For ALL Models ALL 40 and 50 Gallon 40,000 BTH/HR Models only 50 Gallon 40,000 BTU/HR ModelsOptional 4 Vent Piping DIA. Vent Numberof DIA. Vent NumberofCementing PVC, ABS or Cpvc Pipe and Fittings Approximate Setting Time forALL 40 and 50 Gallon 40,000 BTU/HR Models Movement CompleteConnecting PVC, ABS or Cpvc Pipe Vent to Blower Venting Through a Roof ALL ModelsALL 40 and 50 Gallon 40,000 BTH/HR Models only Gas Piping GAS Piping with Flexible Connector Sediment TrapsOperation Operating InstructionsBefore the Water Heater will Operate Check for Leaks Temperature RegulationOperating Water Heating Ignition SequenceTime to Produce For Your Safety Read Before Lighting Burner Cleaning Service and MaintenanceTank Sediment Cleaning Vent System InspectionDraining Gas Control Valve & Burner Assembly Replacement InformationAnode Rod Inspection HousekeepingService Temperature-Pressure Relief Valve OperationDrain Valve Washer Replacement Operational Conditions TroubleshootingStart Up Conditions High Temperature Limit Switch Single-Use Type Energy Cut Off Leakage Checkpoints Troubleshooting YESSystem Check Problem Cause Solution Repair Parts List Maytag GAS Water HeatersKey Model Numbers Part Description HRN11250P HRN31250P Key Model Numbers Part Description HRN11275P HRN31275P MAYTAG/STATE Part Number Conversion KEY Page Page Page Warranty