Maytag HRN11250P, HRP31250P, HRP31240P, HRP11275P, HRN31275P manual Venting Through a Roof ALL Models

Page 24

FIGURE44.

If there is to be a vertical run of vent from blower, the 3” PVC, ABS or CPVC pipe must be attached to the blower using 3 sheet metal screws.

FIGURE42.

The 3” )or optional 2” or 4”) PVC, ABS or CPVC Schedule 40 vent pipe can be run from the water heater through the wall or from the wall to the water heater, whichever is most convenient. The vent pipe must extend a minimum of 1 1/2” through the exterior wall. Extending the vent cap as far as possible from the surface of the exterior wall will help minimize discoloration of the wall in this area which may be caused by the flue gases.

NOTE: that the inside collar must be slipped over the vent piping before locating the pipe through the wall. Before securing the inside and outside collars to the wall, use a silicone sealer between pipe and opening to insure a water and air tight seal.

INSTALLATION SHOWING USE OF PVC, ABS OR CPVC PIPE

FIGURE45.

If the optional 2” vent piping is to be used (40,000 BTU/HR. models only), the 2” street elbow, 3” to 2” reducer and 3” (minimum) section of 3” PVC, ABS or CPVC pipe must be supplied locally. The 3” (minimum) section of 3” PVC, ABS or CPVC pipe must be attached to the blower using 3 sheet metal screws,

If the optional 4” vent piping is to be used (70,000 BTU/HR. and higher models only), the 4” street elbow, 4” to 3” reducer and 3” minimum section of 3” PVC, ABS or CPVC pipe must be supplied locally. The 3” (minimum) section of 3” PVC, ABS or CPVC pipe must be attached to the blower using 3 sheet metal screws.

VENTING THROUGH A ROOF - ALL MODELS

3” PVC, ABS or CPVC Schedule 40 vent piping:

A 3” PVC Schedule 40 - 45o vent cap with wire screen is supplied with the water heater.

3” PVC, ABS or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all models and must be supplied locally.

FIGURE43.

CONNECTING PVC, ABS OR CPVC PIPE VENT TO BLOWER

If making an immediate horizontal run of vent off the blower, a 3” PVC, ABS or CPVC Schedule 40 (supplied locally) elbow is required. Place the elbow in the required direction on the blower and using 3 sheet metal screws, attach the elbow.

75 GALLON 70,000 AND 75,000 BTU/HR MODELS ONLY -

OPTIONAL 4” VENT PIPING

A wiring screen to fit a 4” PVC, ABS or CPVC Schedule 40 - 45o vent cap is supplied with the water heater.

A 3” PVC, ABS or CPVC Schedule 40 pipe, minimum length of 3” (must be supplied locally), to make vent connection at the blower outlet.

A 4” to 3” PVC, ABS or CPVC Schedule 40 reducer (must be supplied locally).

24

Image 24
Contents Series Twelve Safe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents Product Specifications To Install or Operate the Water HeaterCustomer Responsibilities Accessories and Tools Needed AccessoriesAdditional Tools Needed When Sweat Soldering ToolsInstructions for Installation Removing the Old Water HeaterTypical Installation Thermostat Pilot & Main BurnerMixing Valve Usage Locating the NEW Water Heater Facts to Consider About the LocationCombustion Air and Ventilation VentingclearancesVenting Through Roof Clearances Insulation Blankets ALL AIR from Inside BuildingsWater Piping Valve and Pipe Insulation Temperature-Pressure Relief Valve Wiring Filling the Water HeaterWiring Diagram USE Without Power CordVenting Venting Throughan Outside WallGallon 70,000 and 75,000 BTU/HR Models only Optional 4 Vent Piping ALL 40 and 50 Gallon 40,000 BTU/HR Models onlyVenting System Example Installations For ALL Models 50 Gallon 40,000 BTU/HR Models Optional 4 Vent Piping DIA. Vent NumberofALL 40 and 50 Gallon 40,000 BTH/HR Models only DIA. Vent NumberofApproximate Setting Time for ALL 40 and 50 Gallon 40,000 BTU/HR ModelsCementing PVC, ABS or Cpvc Pipe and Fittings Movement CompleteConnecting PVC, ABS or Cpvc Pipe Vent to Blower Venting Through a Roof ALL ModelsALL 40 and 50 Gallon 40,000 BTH/HR Models only Gas Piping GAS Piping with Flexible Connector Sediment TrapsOperating Instructions Before the Water Heater will OperateOperation Temperature Regulation OperatingCheck for Leaks Water Heating Ignition SequenceTime to Produce For Your Safety Read Before Lighting Service and Maintenance Tank Sediment CleaningBurner Cleaning Vent System InspectionGas Control Valve & Burner Assembly Replacement Information Anode Rod InspectionDraining HousekeepingTemperature-Pressure Relief Valve Operation Drain Valve Washer ReplacementService Troubleshooting Start Up ConditionsOperational Conditions High Temperature Limit Switch Single-Use Type Energy Cut Off Leakage Checkpoints Troubleshooting YESSystem Check Problem Cause Solution Repair Parts List Maytag GAS Water HeatersKey Model Numbers Part Description HRN11250P HRN31250P Key Model Numbers Part Description HRN11275P HRN31275P MAYTAG/STATE Part Number Conversion KEY Page Page Page Warranty

HRN11240P, HRP11240P, HRN11275P, HRP11250P, HRP31275P specifications

The Maytag HRP31250P, HRN31275P, HRP31275P, HRP11240P, and HRP11275P are high-efficiency residential heat pumps designed to provide optimal comfort and energy savings for homeowners. These models showcase Maytag's commitment to reliability, durability, and advanced heating technology.

One of the standout features of the Maytag HRP series is its impressive SEER (Seasonal Energy Efficiency Ratio) and HSPF (Heating Seasonal Performance Factor) ratings. These ratings indicate high efficiency, which translates to reduced energy bills and a smaller carbon footprint. The heat pumps operate efficiently in both heating and cooling modes, making them versatile for year-round climate control.

The HRP31250P and HRP31275P models include variable-speed compressors. This technology allows the heat pumps to adjust their output based on the heating or cooling demand. As a result, they maintain consistent indoor temperatures while using less energy. The variable-speed operation also means quieter operation compared to traditional single-stage units, making for a more pleasant home environment.

Additionally, the HRN31275P model stands out with its advanced inverter technology. This technology provides even greater efficiency by allowing the unit to operate at various capacity levels. The inverter-driven compressor ensures that the heat pump runs at the optimal speed, reducing wear and tear and extending the lifespan of the unit.

These models are built with durable materials and incorporate Maytag's robust design principles. They feature a galvanized steel cabinet that is powder-coated to resist rust and corrosion, ensuring that the heat pumps perform effectively for many years. The units come with a limited warranty, reflecting the manufacturer’s confidence in their long-term performance.

The HRP11240P and HRP11275P models are designed for smaller spaces while still offering the same energy-efficient performance found in their larger counterparts. These units are ideal for apartments or homes with limited space for heating and cooling systems. Their compact size does not compromise on performance, making them an excellent choice for those looking for a balance of efficiency and footprint.

Overall, the Maytag HRP series heat pumps represent an investment in home comfort and energy efficiency. With advanced features, reliable performance, and durable construction, these models are well-suited for today's environmentally conscious homeowners seeking dependable heating and cooling solutions.