Maytag HRN11240P manual ALL 40 and 50 Gallon 40,000 BTU/HR Models, Approximate Setting Time for

Page 23

75 GALLON 70,000 AND 75,000 BTU/HR MODELS ONLY

3” DIA. VENT

NUMBEROF

MAX. LENGTH (FT.)

90 ELBOWS*(Inside bldg.)

60

1

55

2

50

3

45

4

40

5

35

6

75 GALLON 70,000 AND 75,000 BTU/HR MODELS ONLY -

OPTIONAL 4” VENT PIPING

4” DIA. VENT

NUMBEROF

MAX. LENGTH (FT.)

90o ELBOWS*(Inside bldg.)

100

1

95

2

90

3

85

4

80

5

75

6

ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS

 

 

3” DIA. VENT

NUMBEROF

MAX. LENGTH (FT.)

90o ELBOWS*(Inside bldg.)

105

1

100

2

95

3

90

4

85

5

80

6

ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS -

OPTIONAL 2” VENT PIPING

2” DIA. VENT

NUMBEROF

MAX. LENGTH (FT.)

90o ELBOWS*(Inside bldg.)

40

1

35

2

30

3

25

4

20

5

15

6

*Two 45o elbows are equivalent to one 90o elbow.

One 90o elbow equals 5 feet of equivalent vent length.

CEMENTING PVC, ABS OR CPVC PIPE AND FITTINGS

Read and observe all safety information printed on primer, cleaner and cement containers.

Primer, cleaner and cements are extremely flammable. They are harmful or fatal if swallowed. The vapors are harmful They may irritate eyes and skin and can be absorbed through the skin.

Always store primers, cleaners and cements in cool, dry, well ventilated places. Do not store them near heat, sparks or flames. Keep containers closed. Use them in well ventilated areas. Wear impervious clothing while handling. Do not smoke, eat or drink while handling. Wash thoroughly after handling and before eating. Wear eye protection when handling. If swallowed, drink water, do not induce vomiting, and call a physician or poison control center immediately. If inhaled, get fresh air and seek medical attention if ill feeling persists. In case of eye and skin contact, immediately flush with plenty of water for 15 minutes and seek medical attention if irritation persists. KEEP OUT AND REACH OF CHILDREN.

All primers, cleaners and cements must meet all local codes and applicable standards of the American Society for Testing Materials Standards.

Before using primers, cleaners and cements, stir or shake, making sure contents of liquid. Do not use if found to be lumpy or jelly-like.

1.Cut pipe ends squarely removing all burrs and dirt.

2.Dry fit pipe and fittings to be connected for proper fit.

3.Clean pipe and fitting with a primer/cleaner.

4.Apply a thin coat of cement to fitting, avoiding puddling inside.

5.Apply a liberal coat of cement to pipe leaving no voids

6.QUICKLY assemble parts while cement is fluid! If you wait too long, re-coat pipes.

7.Push pipe completely into socket of fitting, turning as it goes until it bottoms.

8.Hold pipe and fitting together for 30 seconds. Then carefully clean off excess with a cloth. Allow connections a sufficient time to cure before disturbing.

9.Remember that vent pipes must be adequately and securely supported.

APPROXIMATE SETTING TIME FOR

2 1/2” TO 4” PIPE JOINTS

 

MOVEMENT

COMPLETE

 

OF JOINTS

SET

90o F TO 150o F

3/4 HR.

8 HRS.

50o F TO 90o F

1 HR.

15 HRS.

0o F TO 50o F

1 1/3 HR.

18 HRS.

CUTTING OPENING THROUGH AN OUTSIDE WALL AND COLLAR INSTALLATION

After reading the manual and you have determined the location of the opening in the wall, (using the drawing below), cut a 2 1/2” hole for 2” vent piping, 3 1/2” hole for 3” vent piping or a 4 1/2” hole for 4” vent piping through an exterior wall.

NOTE: When determining location of the opening in the outside wall allow for the 1/8” rise per five feet that has taken place in the horizontal run.

23

Image 23
Contents Series Twelve Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsTo Install or Operate the Water Heater Tools Accessories and Tools NeededAccessories Additional Tools Needed When Sweat SolderingRemoving the Old Water Heater Instructions for InstallationThermostat Pilot & Main Burner Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterVentingclearances Combustion Air and VentilationVenting Through Roof Clearances ALL AIR from Inside Buildings Insulation BlanketsWater Piping Valve and Pipe Insulation Temperature-Pressure Relief Valve Filling the Water Heater WiringUSE Without Power Cord Wiring DiagramGallon 70,000 and 75,000 BTU/HR Models only VentingVenting Throughan Outside Wall ALL 40 and 50 Gallon 40,000 BTU/HR Models only Optional 4 Vent PipingVenting System Example Installations For ALL Models DIA. Vent Numberof 50 Gallon 40,000 BTU/HR ModelsOptional 4 Vent Piping DIA. Vent Numberof ALL 40 and 50 Gallon 40,000 BTH/HR Models onlyMovement Complete Approximate Setting Time forALL 40 and 50 Gallon 40,000 BTU/HR Models Cementing PVC, ABS or Cpvc Pipe and FittingsVenting Through a Roof ALL Models Connecting PVC, ABS or Cpvc Pipe Vent to BlowerALL 40 and 50 Gallon 40,000 BTH/HR Models only Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperation Operating InstructionsBefore the Water Heater will Operate Water Heating Ignition Sequence Temperature RegulationOperating Check for LeaksTime to Produce For Your Safety Read Before Lighting Vent System Inspection Service and MaintenanceTank Sediment Cleaning Burner CleaningHousekeeping Gas Control Valve & Burner Assembly Replacement InformationAnode Rod Inspection DrainingService Temperature-Pressure Relief Valve OperationDrain Valve Washer Replacement Operational Conditions TroubleshootingStart Up Conditions High Temperature Limit Switch Single-Use Type Energy Cut Off Leakage Checkpoints YES TroubleshootingSystem Check Problem Cause Solution Maytag GAS Water Heaters Repair Parts ListKey Model Numbers Part Description HRN11250P HRN31250P Key Model Numbers Part Description HRN11275P HRN31275P MAYTAG/STATE Part Number Conversion KEY Page Page Page Warranty

HRN11240P, HRP11240P, HRN11275P, HRP11250P, HRP31275P specifications

The Maytag HRP31250P, HRN31275P, HRP31275P, HRP11240P, and HRP11275P are high-efficiency residential heat pumps designed to provide optimal comfort and energy savings for homeowners. These models showcase Maytag's commitment to reliability, durability, and advanced heating technology.

One of the standout features of the Maytag HRP series is its impressive SEER (Seasonal Energy Efficiency Ratio) and HSPF (Heating Seasonal Performance Factor) ratings. These ratings indicate high efficiency, which translates to reduced energy bills and a smaller carbon footprint. The heat pumps operate efficiently in both heating and cooling modes, making them versatile for year-round climate control.

The HRP31250P and HRP31275P models include variable-speed compressors. This technology allows the heat pumps to adjust their output based on the heating or cooling demand. As a result, they maintain consistent indoor temperatures while using less energy. The variable-speed operation also means quieter operation compared to traditional single-stage units, making for a more pleasant home environment.

Additionally, the HRN31275P model stands out with its advanced inverter technology. This technology provides even greater efficiency by allowing the unit to operate at various capacity levels. The inverter-driven compressor ensures that the heat pump runs at the optimal speed, reducing wear and tear and extending the lifespan of the unit.

These models are built with durable materials and incorporate Maytag's robust design principles. They feature a galvanized steel cabinet that is powder-coated to resist rust and corrosion, ensuring that the heat pumps perform effectively for many years. The units come with a limited warranty, reflecting the manufacturer’s confidence in their long-term performance.

The HRP11240P and HRP11275P models are designed for smaller spaces while still offering the same energy-efficient performance found in their larger counterparts. These units are ideal for apartments or homes with limited space for heating and cooling systems. Their compact size does not compromise on performance, making them an excellent choice for those looking for a balance of efficiency and footprint.

Overall, the Maytag HRP series heat pumps represent an investment in home comfort and energy efficiency. With advanced features, reliable performance, and durable construction, these models are well-suited for today's environmentally conscious homeowners seeking dependable heating and cooling solutions.