Maytag HRP31275P, HRN11250P, HRP31250P manual Key Model Numbers Part Description HRN11275P HRN31275P

Page 43

REPAIR PARTS LIST

MAYTAG GAS WATER HEATERS

 

MODEL NO’S

HRN11275P

 

75 Gallon Natural Gas

HRN31275P

 

75 Gallon Natural Gas

HRP11275P

 

75 Gallon Propane Gas (L.P.)

HRP31275P

 

75 Gallon Propane Gas (L.P.)

PCV, ABS OR CPVC ITEMS

FOR ALL MODELS SUPPLIED

LOCALLY

Key

 

 

 

Model Numbers

 

No.

Part Description

 

HRN11275P

HRN31275P

HRP11275P

HRP31275P

1

Temperature-Pressure Relief Valve

66001700

66001700

66001700

66001700

2

Primary Anode Rod

66001020

66001020

66001020

66001020

3

Drain Valve

66001015

66001015

66001015

66001015

*4

Drain Valve Washer (17/32” x 13/64” x 1/8” thick)

66001021

66001021

66001021

66001021

5

Pressure Switch

66001294

66001294

66001294

66001294

6

Power Cord

66001372

66001372

66001372

66001372

7

On/Off Switch

66001247

66001247

66001247

66001247

8

Burner Orifice (Drill Size)

66001900

66001901

66001902

66001903

9

Manifold

66001532

66001532

66001532

66001532

10

Burner

66001221

66001221

66001221

66001221

11

Outer Door

66001190

66001190

66001190

66001190

12

Inner Door

66001146

66001146

66001146

66001146

13

Gas Control Valve (Natural)

66001657

66001657

- - - - - - - -

- - - - - - - -

13

Gas Control Valve (Propane{L.P.])

- - - - - - - -

- - - - - - - -

66001658

66001658

14

Dip Tube

66001030

66001030

66001030

66001030

15

Flue Baffle

66001350

66001350

66001350

66001350

16

PV Switch Cover

66001895

66001895

66001895

66001895

17

Cold and Hot Water Nipples

66001148

66001148

66001148

66001148

18

Wiring Harness

66001526

66001526

66001526

66001526

19

T & P Insulation

66001709

66001709

66001709

66001709

20

Water Heater Stand

66001243

66001243

66001243

66001243

21

Draft Hood Ass’y

66001401

66001401

66001401

66001401

22

Gasket Blower

66001291

66001291

66001291

66001291

23

Blower

66001402

66001402

66001402

66001402

24

Wall Collar

66001262

66001262

66001262

66001262

25

Vent-Blower Adapter

66001403

66001403

66001403

66001403

26

Venting Switch

66001342

66001342

66001342

66001342

27

3” PVC Vent Terminal

66001255

66001255

66001255

66001255

28

3” or 4” Schedule 40 Vent Pipe

- - - - - - - - -

- - - - - - - -

- - - - - - - -

- - - - - - - -

29

3” or 4” Schedule 40 90o Elbow

- - - - - - - -

- - - - - - - -

- - - - - - - -

- - - - - - - -

30

Hot Surface Ignition Ass’y

66001524

66001524

66001524

66001524

31

Mounting Bracket

66001896

66001896

66001896

66001896

32

Pipe Insulation (2 ea.)

66001034

66001034

66001034

66001034

*33

Manual

66001897

66001897

66001897

66001897

* Not Shown.

Now that you have purchased this gas water heater, should a need ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Be sure to provide all pertinent facts when you call or visit.

THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.

The model number of this gas water heater will be found on the model rating plate located near the gas control valve.

When ordering repair parts, always give the following information:

Model number

Serial Number

Part Description

Part Number

43

Image 43
Contents Series Twelve Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents To Install or Operate the Water Heater Product SpecificationsCustomer Responsibilities Tools Accessories and Tools NeededAccessories Additional Tools Needed When Sweat SolderingRemoving the Old Water Heater Instructions for InstallationThermostat Pilot & Main Burner Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterVentingclearances Combustion Air and VentilationVenting Through Roof Clearances ALL AIR from Inside Buildings Insulation BlanketsWater Piping Valve and Pipe Insulation Temperature-Pressure Relief Valve Filling the Water Heater WiringUSE Without Power Cord Wiring DiagramVenting Throughan Outside Wall VentingGallon 70,000 and 75,000 BTU/HR Models only ALL 40 and 50 Gallon 40,000 BTU/HR Models only Optional 4 Vent PipingVenting System Example Installations For ALL Models DIA. Vent Numberof 50 Gallon 40,000 BTU/HR ModelsOptional 4 Vent Piping DIA. Vent Numberof ALL 40 and 50 Gallon 40,000 BTH/HR Models onlyMovement Complete Approximate Setting Time forALL 40 and 50 Gallon 40,000 BTU/HR Models Cementing PVC, ABS or Cpvc Pipe and FittingsVenting Through a Roof ALL Models Connecting PVC, ABS or Cpvc Pipe Vent to BlowerALL 40 and 50 Gallon 40,000 BTH/HR Models only Gas Piping Sediment Traps GAS Piping with Flexible ConnectorBefore the Water Heater will Operate Operating InstructionsOperation Water Heating Ignition Sequence Temperature RegulationOperating Check for LeaksTime to Produce For Your Safety Read Before Lighting Vent System Inspection Service and MaintenanceTank Sediment Cleaning Burner CleaningHousekeeping Gas Control Valve & Burner Assembly Replacement InformationAnode Rod Inspection DrainingDrain Valve Washer Replacement Temperature-Pressure Relief Valve OperationService Start Up Conditions TroubleshootingOperational Conditions High Temperature Limit Switch Single-Use Type Energy Cut Off Leakage Checkpoints YES TroubleshootingSystem Check Problem Cause Solution Maytag GAS Water Heaters Repair Parts ListKey Model Numbers Part Description HRN11250P HRN31250P Key Model Numbers Part Description HRN11275P HRN31275P MAYTAG/STATE Part Number Conversion KEY Page Page Page Warranty