Raypak RFSDV34RFPAU, RFSDV34RFNAU manual Delay Timer Mode, Fan Override During Auto Mode

Page 17

Fig.7 Transmitter diagram

Delay Timer Mode

The shut off delay timer maximum setting is 2 hours and minimum setting is zero minutes. To change the timer level, press the timer key, then the arrow key. Each key press changes the setting by 10 minutes.

Auto Mode

In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.

With the control in AUTO mode, the main burner turns ON or OFF or modulates based on the heating differential needed to maintain the set temperature. The flame level adjusts automatically to optimize the heat output required to maintain the set temperature. To change the set temperature, press the UP or DOWN key. Each key press changes the setting by one degree.

In the AUTO mode, the fan speed increases with increased fan height and decreases with the decreased fan height. “AUTO” is displayed next to the flame and fan icons.

Fan Override During Auto Mode

If a higher or lower fan speed is desired when operating in AUTO mode, override the fan speed by pressing the fan button, then the Up or Down key. Each key press changes the fan speed level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the Fan icon.

Change Between F° and C° Temperature Units

Press the Up and Down arrow keys simultaneously for at least 3 seconds to switch between Fahrenheit and Celsius units.

Disable Thermostat Function

To disable the thermostat function in the AUTO mode, press the Timer and Down keys simultaneously for at least 3 seconds.

Page 17 of 27

Image 17
Contents Raypak Vermont RFSDV34 Freestanding GAS LOG Fire Contents Part 7 Conversion What to do if YOU Smell GAS? Part 1 For Your SafetyPart 2 Installation Instructions Locating Your Gas Fireplace Dimension RFSDV34 Preparation Fitting Line InstallationGas Inlet and Burner Pressures Natural Gas Page Part 3 General Flue Installation Glass Cleaning Window Frame Assembly RemovalPart 4 Operating Instructions General Glass InformationMaintenance Log Set and Lava Rock Material InstallationFlame Appearance Flame and Temperature AdjustmentLighting Instructions What to do if you smell gasIf YOU Cannot Contact YOU GAS Supplier Call the Fire Brigade To Turn Off the Heater On Mode Manual Shut Off ProcedureRemote Control Operation Refer to Fig OFF Mode Auto Mode Delay Timer ModeFan Override During Auto Mode Change Between F and C Temperature UnitsTo Change Batteries Part 5 TroubleshootingPage Auto Path Troubleshooting the Gas Control SystemOn Path Part 7 Conversion Instructions Part 6 Replacement Parts ListPart 8 Wiring Diagram RFSDV34 GAS LOG Fire Wiring DiagramPage Page Page Rheem Australia * will PartWarranty Conditions

RFSDV34RFPAU, RFSDV34RFNAU specifications

The Raypak RFSDV34RFNAU and RFSDV34RFPAU are advanced commercial and industrial heat pumps designed for energy-efficient heating, cooling, and pool heating applications. These models embody Raypak's commitment to quality, reliability, and innovative technology, making them ideal for a variety of settings, from residential pools to large-scale commercial facilities.

One of the standout features of the RFSDV34 series is its environmentally friendly refrigerant, which complies with all current regulations while maximizing efficiency. This ensures that operators can maintain their heat pumps with minimal environmental impact, contributing to sustainability efforts in HVAC solutions. The units utilize variable-speed technology, which optimizes performance by adjusting the compressor speed based on the current heating or cooling demands. This not only enhances energy efficiency but also results in quieter operation when compared to conventional fixed-speed systems.

The heat pumps are equipped with advanced digital controls, allowing for precise temperature management and monitoring. Users can easily set desired temperatures and have the peace of mind that the unit will automatically adjust to changes in conditions. The user-friendly interface offers diagnostic capabilities, enabling troubleshooting without the need for extensive manual consultation.

Durability is another hallmark of the RFSDV34 series. The units are constructed with robust materials designed to withstand corrosion and extreme weather conditions. This includes features like a heavy-duty cabinet, weather-resistant components, and high-grade insulation. Consequently, these heat pumps can offer years of reliable service with minimal maintenance.

Additionally, the RFSDV34 models are designed with flexibility in mind. They can be integrated seamlessly into existing systems or used as standalone units. Their compact design allows for easy installation, even in tight spaces, making them an adaptable choice for various applications.

The combination of high performance, energy efficiency, and user-friendly technology positions the Raypak RFSDV34RFNAU and RFSDV34RFPAU as leading choices in the heat pump market. By prioritizing sustainable practices and cutting-edge innovation, Raypak ensures that these heat pumps not only meet industry standards but also exceed customer expectations, providing a reliable solution for heating and cooling needs.