Raypak RFSDV34RFNAU, RFSDV34RFPAU manual Troubleshooting the Gas Control System, On Path, Auto Path

Page 20

Troubleshooting the Gas Control System

Comfort Valve System Control Sequence of Operation with Remote

Control

Local Path

Set manual switch to local or remote

Light pilot burner

Did the LED stop

blinking?

Release pilotstat

knob

Turn pilotstat

knob from PILOT

to ON

Five minute wait period

Review LED

failure analysis

Cycle switch once and leave in remote. Press any key on the Remote Control for recognition operation.

If manual switch is set to LOCAL, did main burner light and fan turn on?

Yes

Turn pilotstat knob to

PILOT to turn off

main burner

Turn pilotstat knob to

OFF to turn valve

completely off.

Choose Manual or Remote path. Set switch to manual or remote.

Move switch from manual to remote.

Press any key on the

remote control.

Move switch back to

On Path

If the manual switch

is set to remote, press the mode button to display ON. Does the remote control the main burner and fan?

Yes

Does remote

control change levels of flame height, fan speed?

Yes

Set levels of flame height and fan to “0” to shut off main burner and fan

Turn pilotstat knob

to OFF to turn

valve completely

off

Move switch from manual to remote. Press any key on remote control

No

Auto Path

If the manual switch

is set to remote, press the mode button to display AUTO. Does the remote control display the room and temperature settings?

If the setting is

above room

temperature on

the remote control

does the main

valve and fan turn

on?

If the setting is

below room

temperature on

the remote

control, does the main valve and fan turn off?

Turn pilotstat knob

to OFF to turn

valve completely

off.

Move switch from

local to remote.

Press any key on

remote control

within 30 seconds

No

No

Page 20 of 27

Image 20
Contents Raypak Vermont RFSDV34 Freestanding GAS LOG Fire Contents Part 7 Conversion Part 1 For Your Safety What to do if YOU Smell GAS?Part 2 Installation Instructions Locating Your Gas Fireplace Dimension RFSDV34 Preparation Fitting Line InstallationGas Inlet and Burner Pressures Natural Gas Page Part 3 General Flue Installation Window Frame Assembly Removal Glass CleaningPart 4 Operating Instructions General Glass InformationLog Set and Lava Rock Material Installation MaintenanceFlame and Temperature Adjustment Flame AppearanceLighting Instructions What to do if you smell gasIf YOU Cannot Contact YOU GAS Supplier Call the Fire Brigade To Turn Off the Heater On Mode Manual Shut Off ProcedureRemote Control Operation Refer to Fig OFF Mode Delay Timer Mode Auto ModeFan Override During Auto Mode Change Between F and C Temperature UnitsPart 5 Troubleshooting To Change BatteriesPage Auto Path Troubleshooting the Gas Control SystemOn Path Part 6 Replacement Parts List Part 7 Conversion InstructionsRFSDV34 GAS LOG Fire Wiring Diagram Part 8 Wiring DiagramPage Page Page Part Rheem Australia * willWarranty Conditions

RFSDV34RFPAU, RFSDV34RFNAU specifications

The Raypak RFSDV34RFNAU and RFSDV34RFPAU are advanced commercial and industrial heat pumps designed for energy-efficient heating, cooling, and pool heating applications. These models embody Raypak's commitment to quality, reliability, and innovative technology, making them ideal for a variety of settings, from residential pools to large-scale commercial facilities.

One of the standout features of the RFSDV34 series is its environmentally friendly refrigerant, which complies with all current regulations while maximizing efficiency. This ensures that operators can maintain their heat pumps with minimal environmental impact, contributing to sustainability efforts in HVAC solutions. The units utilize variable-speed technology, which optimizes performance by adjusting the compressor speed based on the current heating or cooling demands. This not only enhances energy efficiency but also results in quieter operation when compared to conventional fixed-speed systems.

The heat pumps are equipped with advanced digital controls, allowing for precise temperature management and monitoring. Users can easily set desired temperatures and have the peace of mind that the unit will automatically adjust to changes in conditions. The user-friendly interface offers diagnostic capabilities, enabling troubleshooting without the need for extensive manual consultation.

Durability is another hallmark of the RFSDV34 series. The units are constructed with robust materials designed to withstand corrosion and extreme weather conditions. This includes features like a heavy-duty cabinet, weather-resistant components, and high-grade insulation. Consequently, these heat pumps can offer years of reliable service with minimal maintenance.

Additionally, the RFSDV34 models are designed with flexibility in mind. They can be integrated seamlessly into existing systems or used as standalone units. Their compact design allows for easy installation, even in tight spaces, making them an adaptable choice for various applications.

The combination of high performance, energy efficiency, and user-friendly technology positions the Raypak RFSDV34RFNAU and RFSDV34RFPAU as leading choices in the heat pump market. By prioritizing sustainable practices and cutting-edge innovation, Raypak ensures that these heat pumps not only meet industry standards but also exceed customer expectations, providing a reliable solution for heating and cooling needs.