Raypak RFSDV34RFNAU, RFSDV34RFPAU manual Gas Inlet and Burner Pressures Natural Gas, Preparation

Page 8

Gas Specifications

Model

Gas Type

Gas Control

Min. MJ/h

 

Max. MJ/h

 

 

 

 

 

Input

 

Input

RFSDV34RFN

Natural

Radio Freq.

22

 

32

RFSDV34RFP

Propane

Radio Freq.

24

 

32

Gas Inlet and Burner Pressures

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

 

 

ULPG

Inlet Minimum

 

1.1 kPa

 

 

2.75 kPa

Inlet Maximum

 

3.50 kPa

 

 

3.50 kPa

Burner Pressure

 

0.87 kPa

 

 

2.50 kPa

Preparation

Warning: The use of wall paper adjacent to this fireplace is not recommended, as the heat produced by this appliance may adversely affect the binders in the adhesive used to apply the wall paper.

Before beginning, remove the window frame assembly from the heater and ensure that there is not hidden damage to the heater.

Take some time to plan the fitting line, flue and electrical supply.

On completion of the installation ensure that the appliance is commissioned and tested.

Fitting Line Installation

Warning: When purging the fitting line, the front glass must be removed.

Note: For pipe sizing requirements refer to Australian Standard AS5601 Gas Installations.

If gas fitting line has been previously completed, check that the gas fitting line is of adequate size. Refer to Australian Standard AS5601 Gas Installations.

The gas fitting line can be brought in through the rear or the bottom of the appliance. Openings are provided on the bottom behind the valve to allow for the gas fitting line installation and testing of any gas connection. It preferable to bring the fitting line in from the rear right side of the valve as this allows fan installation or removal without the need to disconnect the gas fitting line.

Page 8 of 27

Image 8
Contents Raypak Vermont RFSDV34 Freestanding GAS LOG Fire Contents Part 7 Conversion Part 1 For Your Safety What to do if YOU Smell GAS?Part 2 Installation Instructions Locating Your Gas Fireplace Dimension RFSDV34 Preparation Fitting Line InstallationGas Inlet and Burner Pressures Natural Gas Page Part 3 General Flue Installation Window Frame Assembly Removal Glass CleaningPart 4 Operating Instructions General Glass InformationLog Set and Lava Rock Material Installation MaintenanceFlame and Temperature Adjustment Flame AppearanceLighting Instructions What to do if you smell gasIf YOU Cannot Contact YOU GAS Supplier Call the Fire Brigade To Turn Off the Heater On Mode Manual Shut Off ProcedureRemote Control Operation Refer to Fig OFF Mode Delay Timer Mode Auto ModeFan Override During Auto Mode Change Between F and C Temperature UnitsPart 5 Troubleshooting To Change BatteriesPage Auto Path Troubleshooting the Gas Control SystemOn Path Part 6 Replacement Parts List Part 7 Conversion InstructionsRFSDV34 GAS LOG Fire Wiring Diagram Part 8 Wiring DiagramPage Page Page Part Rheem Australia * willWarranty Conditions

RFSDV34RFPAU, RFSDV34RFNAU specifications

The Raypak RFSDV34RFNAU and RFSDV34RFPAU are advanced commercial and industrial heat pumps designed for energy-efficient heating, cooling, and pool heating applications. These models embody Raypak's commitment to quality, reliability, and innovative technology, making them ideal for a variety of settings, from residential pools to large-scale commercial facilities.

One of the standout features of the RFSDV34 series is its environmentally friendly refrigerant, which complies with all current regulations while maximizing efficiency. This ensures that operators can maintain their heat pumps with minimal environmental impact, contributing to sustainability efforts in HVAC solutions. The units utilize variable-speed technology, which optimizes performance by adjusting the compressor speed based on the current heating or cooling demands. This not only enhances energy efficiency but also results in quieter operation when compared to conventional fixed-speed systems.

The heat pumps are equipped with advanced digital controls, allowing for precise temperature management and monitoring. Users can easily set desired temperatures and have the peace of mind that the unit will automatically adjust to changes in conditions. The user-friendly interface offers diagnostic capabilities, enabling troubleshooting without the need for extensive manual consultation.

Durability is another hallmark of the RFSDV34 series. The units are constructed with robust materials designed to withstand corrosion and extreme weather conditions. This includes features like a heavy-duty cabinet, weather-resistant components, and high-grade insulation. Consequently, these heat pumps can offer years of reliable service with minimal maintenance.

Additionally, the RFSDV34 models are designed with flexibility in mind. They can be integrated seamlessly into existing systems or used as standalone units. Their compact design allows for easy installation, even in tight spaces, making them an adaptable choice for various applications.

The combination of high performance, energy efficiency, and user-friendly technology positions the Raypak RFSDV34RFNAU and RFSDV34RFPAU as leading choices in the heat pump market. By prioritizing sustainable practices and cutting-edge innovation, Raypak ensures that these heat pumps not only meet industry standards but also exceed customer expectations, providing a reliable solution for heating and cooling needs.