WATER HEATER CONTROL

LED STATUS

PROBLEM

 

SOLUTION

A

B C

An open earth ground circuit to the

1. Check that the earth ground connection is

ignition system.

 

properly connected.

 

 

 

2.

Check that the ground conductor on the

 

 

 

 

water heater is properly connected.

A

B C

Wiring error or a high resistance to

1.

Check for proper connection of line

earth ground.

 

neutral and hot wires.

 

 

 

 

 

 

2.

Check that the water heater is securely

 

 

 

 

connected to earth ground.

A

B C

Pressure switch remained closed longer

1.

Pressure switch wiring is incorrect.

 

 

than 5 seconds after the call for

2.

Replace pressure switch.

 

 

heat began.

 

 

A

B C

Pressure switch remained open longer

1.

Pressure switch wiring is incorrect.

than 5 seconds after the combustion

2.

Pressure switch tubing not connected

 

 

 

 

blower was energized.

 

correctly.

 

 

 

3.

Air intake or exhaust obstructed.

A

B C

Error in the hot surface ignitor circuit.

1.

Check that all wiring is correct and secure.

 

 

 

 

 

2.

Replace hot surface ignitor.

 

 

System in lockout.

1.

Gas supply is off or too low to operate.

A

B C

 

2.

Hot surface ignitor not positioned

 

 

correctly.

 

 

 

 

 

 

 

3.

Low voltage to the water heater.

 

 

 

4.

Electric polarity to unit is incorrect - test

 

 

 

 

and correct.

A

B C

Problem in the gas valve driver circuit.

1.

Turn power to the water heater off for

 

 

 

 

10 seconds and the back on.

 

 

 

2.

Replace gas control valve.

A

B C

Problem with the internal circuit.

1.

Turn power to the water heater off for

 

 

 

 

10 seconds and then back on.

 

 

 

2.

Replace gas control valve.

A

B C

Problem with the internal circuit.

1.

Turn power to the water heater off for

 

 

 

 

10 seconds and then back on.

 

 

 

2.

Replace gas control valve.

A

B C

Flame signal sensed out of

1.

Replace gas control valve.

 

 

 

 

proper sequence.

 

 

A

B C

 

 

 

 

 

ECO activated.

1.

Replace gas control valve.

A

B C

One of the temperature adjust

1.

Press and release each of the buttons

 

 

buttons stuck closed.

 

once.

 

 

 

2.

Replace gas control valve.

A

B C

Water temperature sensor is

1.

Check that all wiring is correct and secure.

 

 

 

 

either open or short circuited.

2.

Replace gas control valve.

A

B C

Unit shuts down and in lockout.

1.

Clean and reinstall the air intake screen.

 

 

 

2.

Clean and reinstall the lint screen on the

 

 

 

 

Blower assembly.

A

B C

Unit shuts down.

1.

Check for correct wiring to FV sensor.

 

 

 

2.

Check for open circuits to FV sensor.

 

 

 

3.

Replace FV sensor.

A

B C

Unit shuts down and in lockout.

1.

FV sensor detected presence of flammable vapors.

 

 

 

2.

Contact Maytag Customer Service (1-800-788-8899)

 

 

 

 

to determine cause.

29

Image 29
Contents HV640YBVITCGA HV650YBVITCGA HV640HBVITCGA HV650HBVITCGA Series SixImportant Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Preparing for the Installation Product SpecificationsAttempting to Install or Operate the Water Heater Customer ResponsibilitiesMaterials and Basic Tools Needed AccessoriesPropane HOT Surface Igniter & Main Burner Typical InstallationNatural HOT Surface Igniter & Main Burner Mixing Valve Usage Removing the Old Water Heater Installation InstructionsFacts to Consider about the Location Insulation Blankets ALL AIR from Inside Buildings See Hotter Water can Scald Water PipingValve and Pipe Insulation if supplied TEMPERATURE-PRESSURE Relief ValveGAS Piping GAS Piping with FlexibleconnectorSequenceofinstallation Blower Assembly InstallationSediment Traps Filling the Water HeaterVenting and Installation Vent Connections to Blower AssemblyMaximum Vent Lengths CondensationVenting Vent Terminal InstallationVertical Vent Restrictions Vertical Vent Through RoofRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStepe StepbStepf Step GOperating Instructions PowerbeforeservicingDo not try to light the burner by hand What to do if YOU Smell GASTemperature Setting Burns on Adult Skin Temperature RegulationOperational Conditions For Your InformationStart UP Conditions Burner Cleaning Service and AdjustmentVenting System Inspection Burner Operation and InspectionDrain Valve Washer Replacement TEMPERATURE-PRESSURE Relief Valve OperationService Anode ROD Inspection DrainingLeakage Checkpoints Water Heater Control Troubleshooting GuidelinesTroubleshooting Guidelines Burner Assembly Outer Door Alternate Repair Parts ListMaytag GAS Water Heater HV640YBVITCGALimited Parts Warranty Full ONE Year WarrantyLimited Tank Warranty Against Leaks To Receive Warranty Service