Maytag HN51240X, HN41240X manual Perlinearfoot, Vent Pipeinstallation

Page 16

Instructions for Installation (cont'd)

Gas Piping

All vent gases must be completely vented to the outdoors of

the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal

screws,

TO

CHIMNEY

&WARNING

 

 

[

Make sure the gas supplied is the

same

type listed

[

on the model rating plate. The inlet gas pressure

I

must not exceed 10.5 inches water

column

(2.6 kPa)]

I

for

natural

gas or 13 inches water column (3.2

kPa) I

for

Propane (L.R) gas. The minimum inlet gas pres-

sure listed

on the model rating plate is for the

pur-

pose of input adjustment.

I

 

PERLINEARFOOT

,t

t

&WARNING

If thegas control valve is subjected to pressures I exceeding 1/=pound per square inch (3.5kPa), the I damage to the gas control valve could result in a

VENT PIPEINSTALLATION

There mustbe a minimum of 6" clearance between singlewall vent pipe and any combustible material. Fill and seal any clearance

between single wallvent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than sin-

gle wall, followvent pipe manufacturer's clearance specifications.To

insure a tight fit of the vent pipe in a brick chimney;seal around the

vent pipe with mortar mix cement.

AWARNING

]

 

I

Failure to have required clearances between vent piping and combustible material will result in a fire

hazard,

_,WARNING]

Be sure vent pipe is properly connected to prevent escape of dancjerous flue gases which could cause

deadly asphyxlat on.

A, WARNING]

Chemical vapor corrosion of re" flue and vent sys- I1

tern may occur if air for combustion contains certain I chemical vapors. Spray can propellants, cleaning sol- I

vents, refrigerator and air conditioner refrigerants, I swimming pool chemicals, calcium and sodium chlo- [ ride, waxes, bleach, and process chemicals are typi-

cal compounds which are potentially corrosive.

I

f re or explos on from eak ng gas.

AWARNING[

If the main gas line shutoff serving all gas appli- ances is used, also turn "off" the gas at each appli- ance. Leave all gas appliances shut off until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the latest edition of National Fuel Gas Code ANSI

Z223.1, also referred to as NFPA 54 and the gas company

concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas

controlvalve.

A flexible gas connector or a ground joint union between the shutoffvalve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the

water heater. Use a soapy water solution, not a match or open flame. Rinse offsoapy solution and wipe dry.

StandardModels are for installation up to 3,300 feet above sea level.

High Altitude Models are for installation from 3,300 to 5,500 feet above sea level.

Ifa standard model is installed above 3,300 feet or a high alti-

tude model is installed above 5,500 feet, the input rating must

be reduced at the rate of 4 percent for each 1,000 feet above

sea level. Contact your local gas utility for further information.

&WARNINGI

The appliance and its gas connection must be leak

tested before placing the appliance in operation.

16

Image 16
Contents 1VIAYIAG Safety Instructions Awarning3Safety Instructions on Safety InstructionsPremises Safety Instructions AcautionTable of Contents Product Specifications Customer InformationAccessoriesand Tools Needed Accessories1hewater passingout may Instructions for InstallationThan normalandthisresidue,if spilledout,couldcausestaining Watertemper Outletd Mixingvalve Instructions for Installation contdReliefvalve Instructions for Installation contd Locating the New Water HeaterTopview Withoutdoor OfclosetLocating New Combustion Air and VentilationHeater Contd For Appliances Located Unconfined Spaces For /ppllances Located Confined =pacesInstructions for Installation contd IFigure3ITemperature HotterThreadedto SweatcouplingTemperature-Pressure Relief Valve ShutoffOLD PressureFilling the Water Heater DrafthoodVenttooutdoorsor Drafted ChimneyVent Pipeinstallation PerlinearfootChemical vapor corrosion of re flue and vent sys Tested before placing the appliance in operationFlexible Connector GAS Piping withGassupplypiping ManualInstallation Checklist Instructions for Operation LightingServicete chnicianForceorattemptedrepair STOPReadthesafetyinformationaboveonthislabelThepilotislit , Releaseknobanditwillpopbackup Immediatelycallyourservicetechnicianor gasInstructions for Operation contd Temperature RegulationTurn OFF the manualgascontrolvalve to the appliance Service and Maintenance OUS Bodily Injury or Property DamageBe sure Vent Erly Connected to Prevent Gasses which Could cause deadly AsphyxiationGasControl Valve & Burner Assembly Replacement Information Service and Maintenance contdBurner Cleaning Temperature-Pressure Relief Drain Valve Washer Handlassemblyand CAP WasherHousekeeping DischargepipeTroubleshooting Start Up ConditionsSMOKE/ODOR Thermal ExpansionTroubleshooting contd AIR in HOT Water Faucets AwarningOperational Conditions contd Leakage Checkpoints KCAUTIONETC Repair Parts ListETC5× Repair Parts List contd Model NumbersRepair Parts List contd Odel Numbers KEYHN41240X HN51240X HP41240X HP51240X HN41250X HN51250X Part Descripti on Part NumbersRepair Parts List contd Model Numbers KEY Part Description Part Numbers16 //i MOD EL Numbers KEY 660 0 110 Warranty0002 9164

HN41240X, HN51240X specifications

The Maytag HN51240X and HN41240X are two reliable and efficient washers, offering exceptional performance for those seeking durability and functionality in their laundry routines. These models are designed with a blend of innovative technologies and user-friendly features, making them standout options in the semi-professional segment.

The HN51240X comes equipped with a powerful motor that provides impressive wash action without compromising on efficiency. Its high-capacity drum allows users to tackle large loads easily, perfect for families or individuals with significant laundry needs. Meanwhile, the HN41240X, although slightly smaller, still boasts an impressive capacity that ensures thorough cleaning and better water usage.

Both models feature Maytag’s exclusive PowerWash cycle, which is engineered to tackle tough stains by combining extra agitation, water, and heat. This results in clothes coming out cleaner, even when dealing with heavy soil and grime. Additionally, they utilize the Advanced Moisture Sensing technology that detects moisture levels and adjusts drying time accordingly, preventing over-drying and preserving fabric quality.

The construction of the HN51240X and HN41240X emphasizes durability. Their robust design includes a stainless steel wash basket and a solid, heavy-duty frame, which not only helps reduce vibrations during operation but also ensures long-lasting performance. The machines are designed to withstand the rigors of daily use while maintaining their efficiency and effectiveness.

Another notable characteristic of these models is their energy efficiency. They are ENERGY STAR certified, meaning they meet strict energy efficiency guidelines set by the Environmental Protection Agency. This leads to lower energy bills while still delivering the performance and cleaning power users expect from a Maytag appliance.

For added convenience, both washers feature a variety of wash cycles and options, allowing users to customize their laundry experience. From delicate fabrics to bulky bedding, there is a setting suitable for every type of load. Their intuitive controls make operation straightforward, perfect for users of all experience levels.

In summary, the Maytag HN51240X and HN41240X stand out as quality washing machines that combine innovative technology with user-centric design features. They are perfect for those who value efficiency, durability, and powerful cleaning capabilities in their laundry appliances.