Maytag HN41240X GAS Piping with, Flexible Connector, Gassupplypiping, Manual, Labeleascomdplying

Page 17

Instructions for Installation (cont'd)

Gas Piping

(cont'd)

 

 

 

GAS PIPING WITH

 

,WARNING

FLEXIBLE CONNECTOR

The appliance and its individual shutoff valve

 

must be disconnected from the gas supply piping

 

system during

any pressure testing of the gas sys-

GASSUPPLYPIPING

tem at test pressures in excess of 1/2 pound per square inch (3.SkPa).

The appliance must be isolated from the gas sup-

ply piping

system by closing its individual

manual

[_

 

 

shutoff valve during any

pressure testing

of the

MANUAL

 

 

gas supply

 

piping system

at test

pressures equal

SHUTOFF

 

 

or less than

1/2 pound per square

inch (3.5kPa).

VALVE

 

 

 

 

 

 

 

 

 

 

ELEX,GBLASCOENNECrOR

1

 

_,WARNING

 

 

I

 

WITH ANSI STANDARDS

 

 

 

 

LABELEASCOMDPLYING

I Use pipe joint

compound or teflon

tape

marked as I

GROUNDJOINT

 

 

I being resistant to the action of petroleum

[Propane I

UNION(OPTIONAL)

 

 

I (L'R)]gases"

 

 

 

 

 

I

 

 

 

SEDIMENT

TRAP

 

 

 

 

 

 

 

A sediment trap shall be installed

 

 

 

 

3" MIN.

DRIP LEG

GAS

as close

to the inlet of the

 

(SEDIMENT

CONTROL

 

 

 

 

 

 

 

 

TRAP) CAP

 

water heater as practical at the time of water heater instaUa~

tion. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. Ira tee fitting is used, it shall be

installed in conformance with one of the methods ofinstaUa- tion shown below.

Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two meth- ods shown.

GAS PIPING WITH ALL BLACK IRON PIPE TO

GAS CONTROL

GAS SUPPLY PIPING

SHUTOFF

_WARNINGVALVE

MANUAL t

Contaminants in the gas lines may cause improper

operation of the gas control valve.that may result =in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To

trap any dirt or foreign material in the gas supply

 

 

 

line,

a drip leg

(sometimes called

a sediment trap)

GROUNDJOINT

 

 

must

be incorporated

in the

piping.

The drip leg

UNION

 

 

with the "Gas Piping"

section. Refer

to the latest

 

_

CONTROL

edition of the National

Fuel Gas Code,

ANSI Z223.1

 

 

VALVE

must

be readily

accessible.

Install

in

accordance

 

mACK PIPE _

GAS

also referred to as NFPA 54.

 

 

 

 

DRIPLEG

 

 

 

 

 

 

 

 

 

(SEDIMENT

 

 

 

 

 

 

 

 

3" MIN.

TRAP)

 

CAP

17

Image 17
Contents 1VIAYIAG Awarning Safety InstructionsPremises Safety Instructions3Safety Instructions on Acaution Safety InstructionsTable of Contents Customer Information Product SpecificationsAccessories Accessoriesand Tools NeededThan normalandthisresidue,if spilledout,couldcausestaining Instructions for Installation1hewater passingout may Reliefvalve Instructions for Installation contdWatertemper Outletd Mixingvalve Locating the New Water Heater Instructions for Installation contdTopview Withoutdoor OfclosetCombustion Air and Ventilation Locating NewHeater Contd For Appliances Located Unconfined Spaces For /ppllances Located Confined =pacesIFigure3I Instructions for Installation contdHotter TemperatureThreadedto SweatcouplingShutoff Temperature-Pressure Relief ValveOLD PressureDrafthood Filling the Water HeaterVenttooutdoorsor Drafted ChimneyPerlinearfoot Vent PipeinstallationChemical vapor corrosion of re flue and vent sys Tested before placing the appliance in operationGAS Piping with Flexible ConnectorGassupplypiping ManualInstallation Checklist Lighting Instructions for OperationSTOPReadthesafetyinformationaboveonthislabel Servicete chnicianForceorattemptedrepairThepilotislit , Releaseknobanditwillpopbackup Immediatelycallyourservicetechnicianor gasTurn OFF the manualgascontrolvalve to the appliance Temperature RegulationInstructions for Operation contd OUS Bodily Injury or Property Damage Service and MaintenanceBe sure Vent Erly Connected to Prevent Gasses which Could cause deadly AsphyxiationBurner Cleaning Service and Maintenance contdGasControl Valve & Burner Assembly Replacement Information Handlassemblyand CAP Washer Temperature-Pressure Relief Drain Valve WasherHousekeeping DischargepipeStart Up Conditions TroubleshootingSMOKE/ODOR Thermal ExpansionAIR in HOT Water Faucets Awarning Troubleshooting contdOperational Conditions contd KCAUTION Leakage CheckpointsETC5× Repair Parts ListETC Model Numbers Repair Parts List contdOdel Numbers KEY Repair Parts List contdHN41240X HN51240X HP41240X HP51240X HN41250X HN51250X Part Descripti on Part NumbersRepair Parts List contd Part Description Part Numbers Model Numbers KEY16 //i MOD EL Numbers KEY 0002 9164 Warranty660 0 110

HN41240X, HN51240X specifications

The Maytag HN51240X and HN41240X are two reliable and efficient washers, offering exceptional performance for those seeking durability and functionality in their laundry routines. These models are designed with a blend of innovative technologies and user-friendly features, making them standout options in the semi-professional segment.

The HN51240X comes equipped with a powerful motor that provides impressive wash action without compromising on efficiency. Its high-capacity drum allows users to tackle large loads easily, perfect for families or individuals with significant laundry needs. Meanwhile, the HN41240X, although slightly smaller, still boasts an impressive capacity that ensures thorough cleaning and better water usage.

Both models feature Maytag’s exclusive PowerWash cycle, which is engineered to tackle tough stains by combining extra agitation, water, and heat. This results in clothes coming out cleaner, even when dealing with heavy soil and grime. Additionally, they utilize the Advanced Moisture Sensing technology that detects moisture levels and adjusts drying time accordingly, preventing over-drying and preserving fabric quality.

The construction of the HN51240X and HN41240X emphasizes durability. Their robust design includes a stainless steel wash basket and a solid, heavy-duty frame, which not only helps reduce vibrations during operation but also ensures long-lasting performance. The machines are designed to withstand the rigors of daily use while maintaining their efficiency and effectiveness.

Another notable characteristic of these models is their energy efficiency. They are ENERGY STAR certified, meaning they meet strict energy efficiency guidelines set by the Environmental Protection Agency. This leads to lower energy bills while still delivering the performance and cleaning power users expect from a Maytag appliance.

For added convenience, both washers feature a variety of wash cycles and options, allowing users to customize their laundry experience. From delicate fabrics to bulky bedding, there is a setting suitable for every type of load. Their intuitive controls make operation straightforward, perfect for users of all experience levels.

In summary, the Maytag HN51240X and HN41240X stand out as quality washing machines that combine innovative technology with user-centric design features. They are perfect for those who value efficiency, durability, and powerful cleaning capabilities in their laundry appliances.