Multiquip qp402h manual General Safety, Pump Safety, Serious damage to the equipment or engine

Page 7
DANGEROUS
GAS FUMES

SAFETY INFORMATION

GENERAL SAFETY

CAUTION

„NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

„ NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication.

„NEVER operate this equipment under the infl uence of drugs or alcohol.

NOTICE

„This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.

„Whenever necessary, replace nameplate, operation and safety decals when they become diffi cult read.

„Manufacturer does not assume responsibility for any accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.

„NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

„ ALWAYS know the location of the nearest fire extinguisher.

„ ALWAYS know the location of the nearest first aid kit.

„ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

PUMP SAFETY

DANGER

„NEVER pump volatile, explosive, fl ammable or low fl ash point fl uids. These fl uids could ignite or explode.

„The engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled.

„The engine of this equipment requires an adequate free fl ow of cooling air. NEVER operate this equipment in any enclosed or narrow area

where free fl ow of the air is restricted. If the air fl ow is restricted it will cause injury to people and property and

serious damage to the equipment or engine.

„NEVER operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

WARNING

„NEVER pump corrosive chemicals or water containing toxic substances. These fl uids could create serious health and environmental hazards. Contact local authorities for assistance.

„NEVER open the priming plug when pump

is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug. The possibility exists of scalding, resulting in severe bodily harm.

„NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

QP402H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #2 (01/29/14) — PAGE 7

Image 7
Contents This Manual Must Accompany the Equipment AT ALL Times Model QP402HProposition 65 Warning Page QP402H Centrifugal Pump Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationSerious damage to the equipment or engine General SafetyPump Safety „ Never open the priming plug when pumpFuel Safety Engine SafetyBefore servicing equipment Transporting Safety Battery Safety Electric Start only„ Use well-insulated gloves when picking up the battery Label must remain with the engine for its entire life Emissions InformationModel QP402H Specifications PumpSpecifications Pump Dry Net WeightSpecifications Engines Specifications EngineGeneral Information Drain Plug Remove this plug to drain water from the pump Pump ComponentsInitial Servicing Basic EngineMuffler Used to reduce noise and emissions Season Inspection EngineBefore Starting Oil TypeSetup Place the engine fuel valve lever See to the on position Place the engine ON/OFF switch See in the on positionOperation Starting the EngineAlways run engine at full speed while pumping Stopping the EnginePlace the fuel shut-off lever See in the OFF position Pump Vacuum Test Maintenance PumpPump Vacuum Tester First Every Maintenance EngineEngine Maintenance Engine Maintenance ScheduleEngine OIL Engine AIR CleanerDaily WeeklySpark Arrester Removal Spark Arrester CleaningPump Storage StorageOperation not satisfactory Troubleshooting EngineEngine Troubleshooting Symptom Possible Problem Solution Difficult to startPump Troubleshooting Troubleshooting ENGINE/PUMPSymptom Possible Problem Solution Explanation of Code in Remarks Column Sample Parts ListQty Description Suggested Spare PartsPump Assembly 9430100160 94301000109430100020 ReplacesEngine Service Parts 17210ZE2822 17620Z0T30517620Z4H020 28462ZE2W11Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

qp402h specifications

The Multiquip QP402H is a versatile and powerful portable generator designed to meet the demanding energy needs of various applications, making it an ideal choice for construction sites, events, and emergency power supply. This generator stands out due to its robust construction, reliability, and advanced technologies that contribute to its performance and efficiency.

One of the standout features of the QP402H is its Honda GX270 engine, known for its durability and fuel efficiency. This air-cooled, four-stroke engine provides a consistent power output, ensuring that users have access to the necessary electricity to run various tools and equipment without interruption. With a tank capacity that allows for extended run times, the generator can operate for several hours without frequent refueling, making it particularly suitable for long workdays or events.

The QP402H delivers an impressive power output of 4,000 watts, making it capable of handling multiple electrical devices simultaneously. This makes it a reliable choice for powering heavy-duty equipment, lighting systems, and other essential machinery. Furthermore, the generator is equipped with multiple 120V outlets, which enhance its versatility and allow users to distribute power efficiently across different tools.

In terms of portability, the Multiquip QP402H does not disappoint. It comes with sturdy wheels and a foldable handle, making it easy to transport from one location to another. This is especially beneficial for contractors and event planners who frequently move equipment to different job sites.

Safety features are another hallmark of the QP402H, including a low oil shutdown system that automatically turns off the engine when oil levels are too low. This prevents potential engine damage and reduces maintenance costs. Additionally, the generator is designed with sound reduction technologies, which minimizes noise output, enabling its use in noise-sensitive environments.

The generator’s construction features a heavy-duty frame that offers protection against rugged conditions, ensuring longevity and reliability in the field. Its user-friendly control panel promotes easy operation, allowing even inexperienced users to operate the generator without difficulty.

In summary, the Multiquip QP402H is an exceptional portable generator characterized by its powerful Honda engine, practical power output, and advanced safety features. Its portable design and robust construction make it an excellent choice for various applications, promising reliability and efficiency wherever power is needed.