Multiquip qp402h manual Setup

Page 17

SETUP

1.Place pump as near to water as possible, on a firm flat, level surface.

2.To prime pump, remove fill cap (See Figure 3) and fill pump casing with water. If the pump casing is not filled with water before starting, it will not begin pumping.

3.Attach suction and discharge hoses to the pump. Check that all hoses are securely attached to the pump. Make certain suction hose (See Figure 3) does not have any air leakage. Tighten hose clamps and couplings as required.

4.It is recommended that 2 clamps be used when securing the suction hose to the inlet side (suction) of the pump.

5.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

6.Check that the discharge hose (See Figure 3) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

NOTICE

Suction and discharge hoses are available from Multiquip. Contact your nearest dealer for more information.

7.The discharge hose is usually a collapsible (thin-walled) hose, however if a thin-walled discharge hose is not available, a rigid suction hose can be substituted in its place.

8.Make sure the suction strainer (See Figure 3) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled in to the pump.

CAUTION

The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump.

QP402H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #2 (01/29/14) — PAGE 17

Image 17
Contents This Manual Must Accompany the Equipment AT ALL Times Model QP402HProposition 65 Warning Page QP402H Centrifugal Pump Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationPump Safety General Safety„ Never open the priming plug when pump Serious damage to the equipment or engineBefore servicing equipment Engine SafetyFuel Safety „ Use well-insulated gloves when picking up the battery Battery Safety Electric Start onlyTransporting Safety Label must remain with the engine for its entire life Emissions InformationSpecifications Pump Specifications PumpDry Net Weight Model QP402HSpecifications Engines Specifications EngineGeneral Information Drain Plug Remove this plug to drain water from the pump Pump ComponentsMuffler Used to reduce noise and emissions Basic EngineInitial Servicing Before Starting Inspection EngineOil Type SeasonSetup Operation Place the engine ON/OFF switch See in the on positionStarting the Engine Place the engine fuel valve lever See to the on positionPlace the fuel shut-off lever See in the OFF position Stopping the EngineAlways run engine at full speed while pumping Pump Vacuum Test Maintenance PumpPump Vacuum Tester Engine Maintenance Maintenance EngineEngine Maintenance Schedule First EveryDaily Engine AIR CleanerWeekly Engine OILSpark Arrester Removal Spark Arrester CleaningPump Storage StorageEngine Troubleshooting Troubleshooting EngineSymptom Possible Problem Solution Difficult to start Operation not satisfactorySymptom Possible Problem Solution Troubleshooting ENGINE/PUMPPump Troubleshooting Explanation of Code in Remarks Column Sample Parts ListQty Description Suggested Spare PartsPump Assembly 9430100020 9430100010Replaces 9430100160Engine Service Parts 17620Z4H020 17620Z0T30528462ZE2W11 17210ZE2822Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

qp402h specifications

The Multiquip QP402H is a versatile and powerful portable generator designed to meet the demanding energy needs of various applications, making it an ideal choice for construction sites, events, and emergency power supply. This generator stands out due to its robust construction, reliability, and advanced technologies that contribute to its performance and efficiency.

One of the standout features of the QP402H is its Honda GX270 engine, known for its durability and fuel efficiency. This air-cooled, four-stroke engine provides a consistent power output, ensuring that users have access to the necessary electricity to run various tools and equipment without interruption. With a tank capacity that allows for extended run times, the generator can operate for several hours without frequent refueling, making it particularly suitable for long workdays or events.

The QP402H delivers an impressive power output of 4,000 watts, making it capable of handling multiple electrical devices simultaneously. This makes it a reliable choice for powering heavy-duty equipment, lighting systems, and other essential machinery. Furthermore, the generator is equipped with multiple 120V outlets, which enhance its versatility and allow users to distribute power efficiently across different tools.

In terms of portability, the Multiquip QP402H does not disappoint. It comes with sturdy wheels and a foldable handle, making it easy to transport from one location to another. This is especially beneficial for contractors and event planners who frequently move equipment to different job sites.

Safety features are another hallmark of the QP402H, including a low oil shutdown system that automatically turns off the engine when oil levels are too low. This prevents potential engine damage and reduces maintenance costs. Additionally, the generator is designed with sound reduction technologies, which minimizes noise output, enabling its use in noise-sensitive environments.

The generator’s construction features a heavy-duty frame that offers protection against rugged conditions, ensuring longevity and reliability in the field. Its user-friendly control panel promotes easy operation, allowing even inexperienced users to operate the generator without difficulty.

In summary, the Multiquip QP402H is an exceptional portable generator characterized by its powerful Honda engine, practical power output, and advanced safety features. Its portable design and robust construction make it an excellent choice for various applications, promising reliability and efficiency wherever power is needed.