Multiquip qp402h manual Engine Safety, Fuel Safety, Before servicing equipment

Page 8

SAFETY INFORMATION

CAUTION

„NEVER lubricate components or attempt service on a running machine.

„NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

NOTICE

„ALWAYS fi ll the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump and mechanical seal.

„In winter drain water from pump housing to prevent freezing.

„NEVER start the pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it. Before starting the pump, check that the clean-out cover is securely fastened.

„ALWAYS keep the machine in proper running condition.

„ALWAYS ensure pump is on level ground before use.

„Fix damage to machine and replace any broken parts immediately.

„ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

ENGINE SAFETY

WARNING

„NEVER operate the engine with heat shields or guards removed.

„ DO NOT remove the engine oil drain plug while the engine is hot. Hot oil will gush out of the oil tank and severely scald any persons in the general area of the pump.

CAUTION

„NEVER touch the hot exhaust manifold, muffl er or cylinder. Allow these parts to cool

before servicing equipment.

NOTICE

„NEVER run engine without an air fi lter or with a dirty air fi lter. Severe engine damage may occur. Service air fi lter frequently to prevent engine malfunction.

„NEVER tamper with the factory settings of the engine or engine governor. Damage to the engine or equipment can result if operating in speed ranges above the maximum allowable.

FUEL SAFETY

DANGER

„DO NOT add fuel to equipment if it is placed inside truck bed with plastic liner. Possibility exists of explosion or fi re due to static electricity.

„DO NOT start the engine near spilled fuel or combustible fl uids. Fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

„ALWAYS refuel in a well-ventilated area, away from sparks and open fl ames.

„ALWAYS use extreme caution when working with flammable liquids.

„DO NOT fi ll the fuel tank while the engine is running or hot.

„DO NOT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

PAGE 8 — QP402H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #2 (01/29/14)

Image 8
Contents Model QP402H This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Page Table of Contents QP402H Centrifugal PumpParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Pump Safety„ Never open the priming plug when pump Serious damage to the equipment or engineBefore servicing equipment Engine SafetyFuel Safety „ Use well-insulated gloves when picking up the battery Battery Safety Electric Start onlyTransporting Safety Emissions Information Label must remain with the engine for its entire lifeSpecifications Pump Specifications PumpDry Net Weight Model QP402HSpecifications Engine Specifications EnginesGeneral Information Pump Components Drain Plug Remove this plug to drain water from the pumpMuffler Used to reduce noise and emissions Basic EngineInitial Servicing Inspection Engine Before StartingOil Type SeasonSetup Place the engine ON/OFF switch See in the on position OperationStarting the Engine Place the engine fuel valve lever See to the on positionPlace the fuel shut-off lever See in the OFF position Stopping the EngineAlways run engine at full speed while pumping Maintenance Pump Pump Vacuum TestPump Vacuum Tester Maintenance Engine Engine MaintenanceEngine Maintenance Schedule First EveryEngine AIR Cleaner DailyWeekly Engine OILSpark Arrester Cleaning Spark Arrester RemovalStorage Pump StorageTroubleshooting Engine Engine TroubleshootingSymptom Possible Problem Solution Difficult to start Operation not satisfactorySymptom Possible Problem Solution Troubleshooting ENGINE/PUMPPump Troubleshooting Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts Qty DescriptionPump Assembly 9430100010 9430100020Replaces 9430100160Engine Service Parts 17620Z0T305 17620Z4H02028462ZE2W11 17210ZE2822Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

qp402h specifications

The Multiquip QP402H is a versatile and powerful portable generator designed to meet the demanding energy needs of various applications, making it an ideal choice for construction sites, events, and emergency power supply. This generator stands out due to its robust construction, reliability, and advanced technologies that contribute to its performance and efficiency.

One of the standout features of the QP402H is its Honda GX270 engine, known for its durability and fuel efficiency. This air-cooled, four-stroke engine provides a consistent power output, ensuring that users have access to the necessary electricity to run various tools and equipment without interruption. With a tank capacity that allows for extended run times, the generator can operate for several hours without frequent refueling, making it particularly suitable for long workdays or events.

The QP402H delivers an impressive power output of 4,000 watts, making it capable of handling multiple electrical devices simultaneously. This makes it a reliable choice for powering heavy-duty equipment, lighting systems, and other essential machinery. Furthermore, the generator is equipped with multiple 120V outlets, which enhance its versatility and allow users to distribute power efficiently across different tools.

In terms of portability, the Multiquip QP402H does not disappoint. It comes with sturdy wheels and a foldable handle, making it easy to transport from one location to another. This is especially beneficial for contractors and event planners who frequently move equipment to different job sites.

Safety features are another hallmark of the QP402H, including a low oil shutdown system that automatically turns off the engine when oil levels are too low. This prevents potential engine damage and reduces maintenance costs. Additionally, the generator is designed with sound reduction technologies, which minimizes noise output, enabling its use in noise-sensitive environments.

The generator’s construction features a heavy-duty frame that offers protection against rugged conditions, ensuring longevity and reliability in the field. Its user-friendly control panel promotes easy operation, allowing even inexperienced users to operate the generator without difficulty.

In summary, the Multiquip QP402H is an exceptional portable generator characterized by its powerful Honda engine, practical power output, and advanced safety features. Its portable design and robust construction make it an excellent choice for various applications, promising reliability and efficiency wherever power is needed.