Multiquip qp402h manual Battery Safety Electric Start only, Transporting Safety

Page 9

SAFETY INFORMATION

„Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

„NEVER use fuel as a cleaning agent.

„DO NOT smoke around or near the equipment. Fire or explosion could result from fuel vapors or if fuel is spilled on a hot engine.

BATTERY SAFETY (ELECTRIC START ONLY)

DANGER

„DO NOT drop the battery. There is a possibility that the battery will explode.

„DO NOT expose the battery to open fl ames, sparks, cigarettes, etc.The battery contains combustible gases and liquids. If these

gases and liquids come into contact with a fl ame or spark, an explosion could occur.

WARNING

„ALWAYS wear safety glasses when handling the battery to avoid eye irritation. The battery contains acids that can cause injury to the eyes and skin.

„Use well-insulated gloves when picking up the battery.

„ALWAYS keep the battery charged. If the battery is not charged, combustible gas will build up.

„DO NOT charge battery if frozen. Battery can explode. When frozen, warm the battery to at least 61°F (16°C).

„ALWAYS recharge the battery in a well-ventilated environment to avoid the risk of a dangerous concentration of combustible gases.

„ If the battery liquid (dilute sulfuric acid) comes into contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

„If the battery liquid (dilute sulfuric acid) comes into contact with eyes, rinse eyes immediately with plenty of water and contact the nearest doctor or hospital to seek medical attention.

CAUTION

„ALWAYS disconnect the NEGATIVE battery terminal before performing service on the equipment.

„ALWAYS keep battery cables in good working condition. Repair or replace all worn cables.

TRANSPORTING SAFETY

CAUTION

„NEVER allow any person or animal to stand underneath the equipment while lifting.

NOTICE

„Before lifting, make sure that the equipment parts (hook and vibration insulator) are not damaged and screws are not loose or missing.

„Always make sure crane or lifting device has been properly secured to the lifting bail (hook) of the equipment.

„ALWAYS shutdown engine before transporting.

„NEVER lift the equipment while the engine is running.

„Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling.

„Use adequate lifting cable (wire or rope) of suffi cient strength.

„Use one point suspension hook and lift straight upwards.

„DO NOT lift machine to unnecessary heights.

„ALWAYS tie down equipment during transport by securing the equipment with rope.

QP402H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #2 (01/29/14) — PAGE 9

Image 9
Contents This Manual Must Accompany the Equipment AT ALL Times Model QP402HProposition 65 Warning Page QP402H Centrifugal Pump Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationPump Safety General Safety„ Never open the priming plug when pump Serious damage to the equipment or engineEngine Safety Fuel SafetyBefore servicing equipment Battery Safety Electric Start only Transporting Safety„ Use well-insulated gloves when picking up the battery Label must remain with the engine for its entire life Emissions InformationSpecifications Pump Specifications PumpDry Net Weight Model QP402HSpecifications Engines Specifications EngineGeneral Information Drain Plug Remove this plug to drain water from the pump Pump ComponentsBasic Engine Initial ServicingMuffler Used to reduce noise and emissions Before Starting Inspection EngineOil Type SeasonSetup Operation Place the engine ON/OFF switch See in the on positionStarting the Engine Place the engine fuel valve lever See to the on positionStopping the Engine Always run engine at full speed while pumpingPlace the fuel shut-off lever See in the OFF position Pump Vacuum Test Maintenance PumpPump Vacuum Tester Engine Maintenance Maintenance EngineEngine Maintenance Schedule First EveryDaily Engine AIR CleanerWeekly Engine OILSpark Arrester Removal Spark Arrester CleaningPump Storage StorageEngine Troubleshooting Troubleshooting EngineSymptom Possible Problem Solution Difficult to start Operation not satisfactoryTroubleshooting ENGINE/PUMP Pump TroubleshootingSymptom Possible Problem Solution Explanation of Code in Remarks Column Sample Parts ListQty Description Suggested Spare PartsPump Assembly 9430100020 9430100010Replaces 9430100160Engine Service Parts 17620Z4H020 17620Z0T30528462ZE2W11 17210ZE2822Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

qp402h specifications

The Multiquip QP402H is a versatile and powerful portable generator designed to meet the demanding energy needs of various applications, making it an ideal choice for construction sites, events, and emergency power supply. This generator stands out due to its robust construction, reliability, and advanced technologies that contribute to its performance and efficiency.

One of the standout features of the QP402H is its Honda GX270 engine, known for its durability and fuel efficiency. This air-cooled, four-stroke engine provides a consistent power output, ensuring that users have access to the necessary electricity to run various tools and equipment without interruption. With a tank capacity that allows for extended run times, the generator can operate for several hours without frequent refueling, making it particularly suitable for long workdays or events.

The QP402H delivers an impressive power output of 4,000 watts, making it capable of handling multiple electrical devices simultaneously. This makes it a reliable choice for powering heavy-duty equipment, lighting systems, and other essential machinery. Furthermore, the generator is equipped with multiple 120V outlets, which enhance its versatility and allow users to distribute power efficiently across different tools.

In terms of portability, the Multiquip QP402H does not disappoint. It comes with sturdy wheels and a foldable handle, making it easy to transport from one location to another. This is especially beneficial for contractors and event planners who frequently move equipment to different job sites.

Safety features are another hallmark of the QP402H, including a low oil shutdown system that automatically turns off the engine when oil levels are too low. This prevents potential engine damage and reduces maintenance costs. Additionally, the generator is designed with sound reduction technologies, which minimizes noise output, enabling its use in noise-sensitive environments.

The generator’s construction features a heavy-duty frame that offers protection against rugged conditions, ensuring longevity and reliability in the field. Its user-friendly control panel promotes easy operation, allowing even inexperienced users to operate the generator without difficulty.

In summary, the Multiquip QP402H is an exceptional portable generator characterized by its powerful Honda engine, practical power output, and advanced safety features. Its portable design and robust construction make it an excellent choice for various applications, promising reliability and efficiency wherever power is needed.