13 Finishing |
|
|
|
|
|
|
|
|
|
|
| |
A. Mantel and Wall Projections |
|
|
|
|
|
| ||||||
WARNING! Risk of Fire! Comply with all minimum clear- |
|
|
| 1/2 in. | ||||||||
ances as specified. Framing closer than the minimums list- |
| TOP VIEW |
| |||||||||
|
| Min. | ||||||||||
ed must be constructed entirely of noncombustible materi- |
|
|
|
| ||||||||
als (i.e., steel studs, concrete board, etc.) Failure to comply |
|
|
|
| ||||||||
could cause fire. |
|
|
|
|
|
|
|
|
| FIREPLACE |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| OPENING |
| |
Note: All |
|
|
|
|
|
|
|
|
|
| Min. | Unlimited |
measurements |
|
|
|
|
|
| CEILING |
|
|
|
|
|
in inches. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Note: Clearance from opening to |
| |
| MAX. |
|
|
|
|
|
|
|
| perpendicular wall. |
|
|
|
|
|
| 12 |
|
|
|
| Figure 13.3 Combustible Mantel Leg or Wall Projections | |||
|
|
| 11 |
|
|
|
|
| (Acceptable on both sides of opening) | |||
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
| 8 | 9 |
|
|
|
|
|
|
|
|
|
| 7 |
|
|
|
| 32 |
| B. Facing Material |
|
| ||
|
|
|
|
|
|
|
|
| ||||
5 | 6 |
|
|
|
|
|
| MIN. | • | Metal front faces may be covered with | ||
|
|
|
|
|
| 12 13 | ||||||
4 |
|
|
|
|
| 10 11 |
|
| materials only. |
|
| |
3 |
|
| 6 | 7 | 8 9 |
|
| • Facing and/or finishing materials must not interfere with | ||||
| 4 | 5 |
|
|
|
|
| air flow through louvers, operation of louvers or doors, | ||||
|
|
|
|
|
|
|
|
| or access for service. |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| • | Facing and/or finishing materials must never overhang | ||
TOP OF HOOD OR FIREPLACE OPENING |
| into the glass opening. |
|
| ||||||||
|
|
|
|
|
|
|
|
| • Observe all clearances when applying combustible | |||
|
|
|
|
|
|
|
|
|
| materials. |
|
|
|
|
|
|
|
|
|
|
| • | Seal joints between the finished wall and appliance top | ||
Figure 13.1 Minimum Vertical and Maximum Horizontal |
|
| and sides using a 300 °F minimum sealant. Refer to | |||||||||
|
| Figure 13.3. |
|
| ||||||||
Dimensions of Combustibles |
|
|
| WARNING! Risk of Fire! DO NOT apply combustible | ||||||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| materials beyond the minimum clearances. Comply with | |||
Note: All |
|
|
|
|
|
|
|
| all minimum clearances to combustibles as specified in | |||
measurements |
|
|
|
| CEILING |
|
| this manual. Overlapping materials could ignite and will | ||||
in inches. |
|
|
|
|
|
| ||||||
MAX. |
|
|
|
| interfere with proper operation of doors and louvers. | |||||||
|
|
|
|
|
|
| ||||||
|
|
|
|
| 18 |
|
|
|
|
|
|
|
|
|
|
| 12 |
|
|
|
| Finish wall material may be |
| ||
|
|
|
| 11 |
|
|
|
|
| combustible - Top and Sides |
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 10 |
|
| 32 |
|
|
|
|
| |
|
|
| 9 |
|
|
|
|
|
|
| ||
|
|
|
|
|
| MIN. |
|
|
|
| 0 in. | |
|
|
|
|
|
| 14 |
|
|
|
| ||
|
| 8 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| 8 |
|
|
|
|
|
| ||
| 7 |
|
|
| 7 |
|
|
|
|
|
| |
| 6 |
| 4 | 5 | 6 |
|
|
|
|
|
|
|
| 5 | 2 | 3 |
|
|
|
|
|
|
|
|
|
4 | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
TOP OF HOOD OR FIREPLACE OPENING |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| 0 in. |
| 0 in. |
|
|
|
|
|
|
|
|
|
| High Temperature Sealant (300° F/149° C min.) | ||
Figure 13.2 Minimum Vertical and Maximum Horizontal |
|
| Top and Side Seal Joint |
| ||||||||
|
| Figure 13.4 Noncombustible Facing Diagram | ||||||||||
Dimensions of |
|
|
|
Heatilator • GDST3831I • | 45 |