Pelco C3433M (3/07) manual Troubleshooting

Page 19

Troubleshooting

Problem

Possible Cause

Suggested Remedy

 

 

 

No video

PoE power issue

• Check CAT 5 cable connection.

 

 

• Check PoE injector power.

 

 

• Disconnect CAT 5 cable from the PoE and then

 

 

reconnect cable. Check the LED inside the back box

 

 

to see if it is flashing green 5 times per second for

 

 

approximately two minutes, indicating the camera

 

 

has power.

 

 

 

 

Power issue (24 VAC)

• Check the 24 VAC power supply connection.

 

 

• Disconnect the network cable and then reconnect

 

 

the cable to the camera. Check the LED inside the

 

 

back box to verify if it is flashing green 5 times per

 

 

second for approximately two minutes, indicating

 

 

the camera has power.

 

 

 

 

Network connectivity issues

• Check network cable connections.

 

 

• Disconnect the network cable and then reconnect

 

 

the cable to the camera. Check the LED inside the

 

 

back box to verify if it is flashing green.

 

 

• Replace network cable with new cable. If new

 

 

cable does not work, contact Pelco’s Product

 

 

Support Department at 1-559-292-1981 or

 

 

1-800-289-9100.

 

 

 

 

Defective camera

• Check the camera’s 10-pin connector inside the

 

 

back box to make sure it is connected.

 

 

• Use a service connector to check camera operation.

 

 

Connect one end of the service connector to the

 

 

service connector input inside the back box. Then

 

 

connect the other end of the service connector to a

 

 

monitor.

 

 

• Replace camera module with new camera. If the

 

 

new camera does not work, contact Pelco’s Product

 

 

Support Department at 1-559-292-1981 or

 

 

1-800-289-9100.

 

 

 

 

Java not installed

Install Java Runtime Environment (JRE) from the IP110

 

 

resource CD shipped with this product. It is also

 

 

available at the following:

 

 

http://www.pelco.com/software/downloads

 

 

 

Flickering in

Flickerless setting

• Check DIP switch settings.

image

 

• Check power supply specifications.

 

 

• Replace camera module with new camera. If the

 

 

new camera does not work, contact Pelco’s Product

 

 

Support Department at 1-559-292-1981 or

 

 

1-800-289-9100.

 

 

 

C3433M (3/07)

19

Image 19
Contents IP110 Series Camclosure Web Browser Contents Video QUALITY-CAUTION Regarding User Selected Options Welcome IP Address SettingsGetting Started Accessing the Camera Using a Web BrowserTo access the IP110 do the following Open the Web browser Home Screen IP110 Main MenuHOW to Capture a Still Image Image Rate SettingFull Screen Mode Scalable Stream ModeGeneral TAB Settings ScreenChange the Device Name Network TAB How to Change the Network SettingsUsers Tab Users TABHow to Modify a User Profile How to Add a New UserHow to Delete a User Profile Roles TAB How to Create a New RoleHow to Delete a Role How to Modify an Existing RoleFor help with the system select the Online help menu Edit Profile ScreenHelp Screen Sign OUT ScreenInstalling the IP110 Device Utility How to Use the Device UtilityUpdating Firmware Update FirmwareSelect the file to upload and then click the open button Update StatusDevice Utility Accessing the Camera Troubleshooting Router with an n-Port switch Camera not No camera powerGreen LED during camera power-up Network not Faulty cable connectionSpecifications Interlace Signal System Ntsc or PAL Scanning SystemImaging Device Inch imager Dynamic Range DB typical/120 dB maximumProduct Warranty and Return Information ISO9001