Image quality | Image not focused | Adjust the field of view and the focus. |
|
|
|
| 15 ips quality bad | In some networks with high latency, the maximum |
|
| frame rate may not be attainable. |
|
|
|
| 30 ips not available | The IP110 only supports MJPEG at rate up to 15 ips for |
|
| NTSC camera modules where applicable. For PAL |
|
| camera modules, the maximum rate is 12 ips only. |
|
|
|
No dual streams | Web browser | Not available with Web browser. Only supported by |
|
| Endura™ system or Pelco’s API Interface solution. |
|
|
|
Cannot record an | Web browser | Not available with Web browser. Only supported by |
MJPEG stream |
| Endura system or Pelco’s API Interface solution. |
|
|
|
MPEG4 not | Web browser | Not available with Web browser. Only supported by |
available |
| Endura system or Pelco’s API Interface solution. |
|
|
|
Camera not | No camera power | Verify the camera is powered correctly with PoE or |
discovered |
| with 24 VAC. Confirm power consumption with web |
|
| interface of |
|
| green LED during camera |
|
|
|
| Network conflict | Verify the camera is physically connected to the same |
|
| network as the PC running the Device Utility. |
|
|
|
Network not | Faulty cable connection | Check all cable connections and ensure all plugs are |
working |
| properly plugged in. |
|
|
|
| Incorrect serial device | A hub will not work with the available network |
| configuration | bandwidth shared across all ports. Use a Fast Ethernet |
|
| switch, Gigabit Ethernet switch, or a |
|
| router with an |
|
|
|
| Network connectivity issues | Contact your network administrator. |
|
|
|
20 | C3433M (3/07) |