Pelco IV SE manual 100

Page 13

Table B. Switch Settings for SW1 D-Type Control (Continued)

SPECTRA

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

 

 

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

 

71

ON

ON

ON

OFF

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

72

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

73

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

74

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

75

ON

ON

OFF

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

76

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

77

ON

OFF

ON

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

78

OFF

ON

ON

ON

OFF

OFF

ON

OFF

79

ON

ON

ON

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

80

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

81

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

82

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

83

ON

ON

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

84

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

85

ON

OFF

ON

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

86

OFF

ON

ON

OFF

ON

OFF

ON

OFF

87

ON

ON

ON

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

88

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

89

ON

OFF

OFF

ON

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

90

OFF

ON

OFF

ON

ON

OFF

ON

OFF

91

ON

ON

OFF

ON

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

92

OFF

OFF

ON

ON

ON

OFF

ON

OFF

93

ON

OFF

ON

ON

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

94

OFF

ON

ON

ON

ON

OFF

ON

OFF

95

ON

ON

ON

ON

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

96

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF

97

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

98

OFF

ON

OFF

OFF

OFF

ON

ON

OFF

99

ON

ON

OFF

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

100

OFF

OFF

ON

OFF

OFF

ON

ON

OFF

101

ON

OFF

ON

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

102

OFF

ON

ON

OFF

OFF

ON

ON

OFF

103

ON

ON

ON

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

104

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

105

ON

OFF

OFF

ON

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

C3434M-A (9/07)

13

Image 13
Contents Spectra IV SE Horizon Series Dome Drive Page Contents Shutter Speed Scheduled Events Welcome Switch Settings InstallationSW1 Receiver Address SW2 Switches 4-5 Serial Port Settings SW2 Switches 1-3 Special System SettingsSW2 Switches 6-8 Baud Settings BaudDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Spectra Switch Setting Address Table B. Switch Settings for SW1 D-Type ControlTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Getting Started Configure DoneHow to Operate Your Dome System Quick Programming Guide Accessing Main Menu PresetPress the Spot Monitor key CM9500VCD5000 Endura WorkstationSpectra IV SE Horizon Menu Tree Dome Settings Camera Language Back Exit Additional System InformationDisplay Setup Label Positions Camera Dome SettingsType of Lighting Auto FocusZoom Speed Zoom LimitLOW Light Limit HighYES IR CUT FilterDark Shutter Speed Advanced Camera SettingsAGC Limit Numeric ValueDetermined by the auto iris level setting Auto iris is disabled, and control is always manualAuto Iris Auto Sharpness Level. Sharpness level settings range fromAuto White Balance GainBacklight Compensation BLC There are two backlight compensation settingsWide Dynamic Range Video LevelSet the video output to one of the following NormalElectronic Image Stabilization DefaultImage Enhancement EnhancedThere are two auto flip modes On default Motion SettingsAuto Flip Proportional PANPark Time PresetAuto Scan Frame ScanThere are three preset freeze frame settings Preset Freeze FrameScan Speed Image is never frozenManual Limit StopsScan Stop is reachedAzimuth Zero Power UP Action Power UPNone Line Sync Settings range from zero to 359 degreesDome synchronizes to the internal clock Following presets are predefined for specific functions PresetsBecomes Pelco Spectra IV SE Horizon Language Following are the settings for motion detection OFF default Enable Motion DetectionMedium default Average sensitivity Edit Detection AreasMotion Detection Areas Triggers a command to AUX Activate AUX CommandAUX Time Edit SchedulePatterns Zones To set a window blanking area Window BlankingClear Window ReverseBlank ALL ABOVE/BLANK ALL below Reset Delay AlarmsResume SequenceMEDIUM/LOW Normally open Latching AUXMomentary Edit Title Text Title TextClear Password Clock Power LineFixed Date Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Type EventEvent Label Edit Event Label Edit Event LabelDate is in the list of holidays Edit EventHolidays have no effect on the event List Event Clear EventHoliday Holiday occurs on the same date each year Edit HolidayApril List Holidays Clear HolidayUse this page to record scheduled events Scheduled EventsReset Camera Reset, Cycle Power, RebootCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance Ntsc SpecificationsInterlace Inch CCD PAL Product Warranty and Return Information ISO9001
Related manuals
Manual 96 pages 46.76 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.