Pelco IV SE manual Becomes

Page 47

PELCO SPECTRA IV SE HORIZON

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

PRESETS

PRESET NUMBER

1

* * * PRESET NOT DEFINED * * *

 

<EDIT PRESET LABEL>

 

<EDIT PRESET SCENE>

 

<EDIT CAMERA SETTINGS>

 

<MOTION DETECTION>

 

<EDIT SCHEDULE>

 

<CLEAR PRESET>

 

<CLEAR CAMERA SETTINGS>

 

BACK

 

EXIT

 

REFERENCE INFORMATION

-

AZIMUTH

ELEVATION

-

ZOOM RATIO

-

CUSTOM CAMERA SETTINGS

-

NOTE: For American Dynamics controllers with only 32 presets, switch SW2-1 on the dome drive to the ON position. When SW2-1 is ON, preset

99 becomes 32

92 becomes 25

98 becomes 31

91 becomes 24

97 becomes 30

90 becomes 23

96 becomes 29

89 becomes 22

95 becomes 28

88 becomes 21

93 becomes 26

 

If the limit stops are turned off, presets 23-26 can be used as regular presets.

Use the following steps to program a preset.

1.Select the preset number:

a.Use the joystick to position the cursor beside PRESET NUMBER. Press Iris Open. The cursor moves to the right.

b.Move the joystick up or down to view selections. Press Iris Open to enter selection.

2.Edit the preset label:

a.Use the joystick to position the cursor beside EDIT PRESET LABEL.

b.Press Iris Open. The following appears on the monitor:

LABEL FOR PRESET

PRESET NUMBER ------

1234567890

OK

ABCDEFGHIJ

CANCEL

KLMNOPQRST

 

UVWXYZ.,-/

SPACE

abcdefghij

BACKSPACE

klmnopqrst

 

uvwxyz*;:

 

c.Use the joystick to position the cursor beside a character. Press Iris Open to enter selection. To clear a character, position the cursor beside BACKSPACE, and then press Iris Open.

d.When label is completed, move the cursor to OK. Press Iris Open to return to the Preset menu.

3.Edit the preset scene:

a.Use the joystick to position the cursor beside EDIT PRESET SCENE.

b.Press Iris Open.

c.Follow the directions displayed on the monitor.

C3434M-A (9/07)

47

Image 47
Contents Spectra IV SE Horizon Series Dome Drive Page Contents Shutter Speed Scheduled Events Welcome SW1 Receiver Address InstallationSwitch Settings Baud SW2 Switches 1-3 Special System SettingsSW2 Switches 4-5 Serial Port Settings SW2 Switches 6-8 Baud SettingsDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Spectra Switch Setting Address Table B. Switch Settings for SW1 D-Type ControlTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Getting Started Configure DoneHow to Operate Your Dome System Quick Programming Guide Accessing Main Menu PresetPress the Spot Monitor key CM9500VCD5000 Endura WorkstationSpectra IV SE Horizon Menu Tree Dome Settings Camera Language Back Exit Additional System InformationDisplay Setup Label Positions Auto Focus Dome SettingsCamera Type of LightingHigh Zoom LimitZoom Speed LOW Light LimitDark IR CUT FilterYES Numeric Value Advanced Camera SettingsShutter Speed AGC LimitAuto Iris Auto iris is disabled, and control is always manualDetermined by the auto iris level setting Gain Level. Sharpness level settings range fromAuto Sharpness Auto White BalanceBacklight Compensation BLC There are two backlight compensation settingsNormal Video LevelWide Dynamic Range Set the video output to one of the followingEnhanced DefaultElectronic Image Stabilization Image EnhancementProportional PAN Motion SettingsThere are two auto flip modes On default Auto FlipFrame Scan PresetPark Time Auto ScanImage is never frozen Preset Freeze FrameThere are three preset freeze frame settings Scan SpeedStop is reached Limit StopsManual ScanAzimuth Zero None Power UPPower UP Action Dome synchronizes to the internal clock Settings range from zero to 359 degreesLine Sync Following presets are predefined for specific functions PresetsBecomes Pelco Spectra IV SE Horizon Language Edit Detection Areas Enable Motion DetectionFollowing are the settings for motion detection OFF default Medium default Average sensitivityMotion Detection Areas Edit Schedule Activate AUX CommandTriggers a command to AUX AUX TimePatterns Zones To set a window blanking area Window BlankingClear Window ReverseBlank ALL ABOVE/BLANK ALL below Sequence AlarmsReset Delay ResumeMEDIUM/LOW Normally open Momentary AUXLatching Edit Title Text Title TextClear Password Fixed Date Power LineClock Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Label EventEvent Type Edit Event Label Edit Event LabelHolidays have no effect on the event Edit EventDate is in the list of holidays Holiday Clear EventList Event April Edit HolidayHoliday occurs on the same date each year List Holidays Clear HolidayUse this page to record scheduled events Scheduled EventsReboot System Reset, Cycle Power, RebootReset Camera Cycle Camera PowerSoftware/Language File Upload Suggested Preventative Maintenance Interlace Inch CCD SpecificationsNtsc PAL Product Warranty and Return Information ISO9001
Related manuals
Manual 96 pages 46.76 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.