Pelco IV SE manual 106

Page 14

Table B. Switch Settings for SW1 D-Type Control (Continued)

SPECTRA

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

 

 

ADDRESS

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

 

106

OFF

ON

OFF

ON

OFF

ON

ON

OFF

107

ON

ON

OFF

ON

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

108

OFF

OFF

ON

ON

OFF

ON

ON

OFF

109

ON

OFF

ON

ON

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

110

OFF

ON

ON

ON

OFF

ON

ON

OFF

111

ON

ON

ON

ON

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

112

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

113

ON

OFF

OFF

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

114

OFF

ON

OFF

OFF

ON

ON

ON

OFF

115

ON

ON

OFF

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

116

OFF

OFF

ON

OFF

ON

ON

ON

OFF

117

ON

OFF

ON

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

118

OFF

ON

ON

OFF

ON

ON

ON

OFF

119

ON

ON

ON

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

120

OFF

OFF

OFF

ON

ON

ON

ON

OFF

121

ON

OFF

OFF

ON

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

122

OFF

ON

OFF

ON

ON

ON

ON

OFF

123

ON

ON

OFF

ON

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

124

OFF

OFF

ON

ON

ON

ON

ON

OFF

125

ON

OFF

ON

ON

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

126

OFF

ON

ON

ON

ON

ON

ON

OFF

127

ON

ON

ON

ON

ON

ON

ON

OFF

 

 

 

 

 

 

 

 

 

128

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

129

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

130

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

131

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

132

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

133

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

134

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

135

ON

ON

ON

OFF

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

136

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

137

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

138

OFF

ON

OFF

ON

OFF

OFF

OFF

ON

139

ON

ON

OFF

ON

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

140

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

14

C3434M-A (9/07)

Image 14
Contents Spectra IV SE Horizon Series Dome Drive Page Contents Shutter Speed Scheduled Events Welcome SW1 Receiver Address InstallationSwitch Settings SW2 Switches 6-8 Baud Settings SW2 Switches 1-3 Special System SettingsSW2 Switches 4-5 Serial Port Settings BaudDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Table B. Switch Settings for SW1 D-Type Control Spectra Switch Setting AddressTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Configure Done Getting StartedHow to Operate Your Dome System Accessing Main Menu Preset Quick Programming GuideCM9500 Press the Spot Monitor keyEndura Workstation VCD5000Spectra IV SE Horizon Menu Tree Dome Settings Camera Language System Information Back Exit AdditionalDisplay Setup Label Positions Type of Lighting Dome SettingsCamera Auto FocusLOW Light Limit Zoom LimitZoom Speed HighDark IR CUT FilterYES AGC Limit Advanced Camera SettingsShutter Speed Numeric ValueAuto Iris Auto iris is disabled, and control is always manualDetermined by the auto iris level setting Auto White Balance Level. Sharpness level settings range fromAuto Sharpness GainThere are two backlight compensation settings Backlight Compensation BLCSet the video output to one of the following Video LevelWide Dynamic Range NormalImage Enhancement DefaultElectronic Image Stabilization EnhancedAuto Flip Motion SettingsThere are two auto flip modes On default Proportional PANAuto Scan PresetPark Time Frame ScanScan Speed Preset Freeze FrameThere are three preset freeze frame settings Image is never frozenScan Limit StopsManual Stop is reachedAzimuth Zero None Power UPPower UP Action Dome synchronizes to the internal clock Settings range from zero to 359 degreesLine Sync Presets Following presets are predefined for specific functionsBecomes Pelco Spectra IV SE Horizon Language Medium default Average sensitivity Enable Motion DetectionFollowing are the settings for motion detection OFF default Edit Detection AreasMotion Detection Areas AUX Time Activate AUX CommandTriggers a command to AUX Edit SchedulePatterns Zones Window Blanking To set a window blanking areaReverse Clear WindowBlank ALL ABOVE/BLANK ALL below Resume AlarmsReset Delay SequenceMEDIUM/LOW Normally open Momentary AUXLatching Title Text Edit Title TextClear Password Fixed Date Power LineClock Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Label EventEvent Type Edit Event Label Edit Event LabelHolidays have no effect on the event Edit EventDate is in the list of holidays Holiday Clear EventList Event April Edit HolidayHoliday occurs on the same date each year Clear Holiday List HolidaysScheduled Events Use this page to record scheduled eventsCycle Camera Power Reset, Cycle Power, RebootReset Camera Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance Interlace Inch CCD SpecificationsNtsc PAL Product Warranty and Return Information ISO9001
Related manuals
Manual 96 pages 46.76 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.