SW2 SWITCHES 1-3: SPECIAL SYSTEM SETTINGS

AD-32 Preset System

SW2-1 should be set to the ON position if an AD-32 controller and Pelco’s TXB-AD translator board are used to control the dome system.

CM9502 Setting

If a CM9502 matrix system is used with the dome drive, set SW2-2 to the ON position.

Vicon System

The Vicon® protocol is not currently available. SW2-3 is reserved for future use.

SW2 SWITCHES 4-5: SERIAL PORT SETTINGS

RS422 Setting (Default)

SW2-4 and SW2-5 should both be set to the OFF position for RS422 setting.

For control, only two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box. For bidirectional control, four wires should be connected to the RX-, RX+, TX-, and TX+ connectors on the circuit board inside the back box.

RS485, 4 Wire Setting

SW2-4 should be set to OFF and SW2-5 should be set to ON if a four wire serial port connection is used with RS485.

NOTE: This setting is most commonly used with Pelco Endura® systems.

RS485, 2 Wire Setting

SW2-4 and SW2-5 should both be set to the ON position if a two wire serial port connection is used with RS485.

This setting is used to allow the Spectra dome system to transmit and receive commands on the same pair of wires. Only two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box.

SW2 SWITCHES 6-8: BAUD SETTINGS

Pelco’s D-type controllers are set for 2400 baud. The default setting for the dome drive is 2400 baud. If you are using a Pelco D-type controller, do not reset SW2 switches 1 through 3 or SW2 switches 6 through 8.

P-type controllers can operate at 2400, 4800, and 9600 baud. Set the SW2 switches (6, 7, and 8), located on the base of the dome drive, to the same baud as the P-type controller.

Switch Number

SW2-6

SW2-7

SW2-8

 

 

 

 

 

2400

Baud (default for D-type control)

Off

Off

Off

 

 

 

 

 

4800

Baud (default for P-type control)

On

Off

Off

 

 

 

 

 

9600

Baud

Off

On

Off

 

 

 

 

 

8

C3434M-A (9/07)

Image 8
Contents Spectra IV SE Horizon Series Dome Drive Page Contents Shutter Speed Scheduled Events Welcome SW1 Receiver Address InstallationSwitch Settings SW2 Switches 1-3 Special System Settings SW2 Switches 4-5 Serial Port SettingsSW2 Switches 6-8 Baud Settings BaudDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Table B. Switch Settings for SW1 D-Type Control Spectra Switch Setting AddressTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Configure Done Getting StartedHow to Operate Your Dome System Accessing Main Menu Preset Quick Programming GuideCM9500 Press the Spot Monitor keyEndura Workstation VCD5000Spectra IV SE Horizon Menu Tree Dome Settings Camera Language System Information Back Exit AdditionalDisplay Setup Label Positions Dome Settings CameraType of Lighting Auto FocusZoom Limit Zoom SpeedLOW Light Limit HighDark IR CUT FilterYES Advanced Camera Settings Shutter SpeedAGC Limit Numeric ValueAuto Iris Auto iris is disabled, and control is always manualDetermined by the auto iris level setting Level. Sharpness level settings range from Auto SharpnessAuto White Balance GainThere are two backlight compensation settings Backlight Compensation BLCVideo Level Wide Dynamic RangeSet the video output to one of the following NormalDefault Electronic Image StabilizationImage Enhancement EnhancedMotion Settings There are two auto flip modes On defaultAuto Flip Proportional PANPreset Park TimeAuto Scan Frame ScanPreset Freeze Frame There are three preset freeze frame settingsScan Speed Image is never frozenLimit Stops ManualScan Stop is reachedAzimuth Zero None Power UPPower UP Action Dome synchronizes to the internal clock Settings range from zero to 359 degreesLine Sync Presets Following presets are predefined for specific functionsBecomes Pelco Spectra IV SE Horizon Language Enable Motion Detection Following are the settings for motion detection OFF defaultMedium default Average sensitivity Edit Detection AreasMotion Detection Areas Activate AUX Command Triggers a command to AUXAUX Time Edit SchedulePatterns Zones Window Blanking To set a window blanking areaReverse Clear WindowBlank ALL ABOVE/BLANK ALL below Alarms Reset DelayResume SequenceMEDIUM/LOW Normally open Momentary AUXLatching Title Text Edit Title TextClear Password Fixed Date Power LineClock Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Label EventEvent Type Edit Event Label Edit Event LabelHolidays have no effect on the event Edit EventDate is in the list of holidays Holiday Clear EventList Event April Edit HolidayHoliday occurs on the same date each year Clear Holiday List HolidaysScheduled Events Use this page to record scheduled eventsReset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance Interlace Inch CCD SpecificationsNtsc PAL Product Warranty and Return Information ISO9001
Related manuals
Manual 96 pages 46.76 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.