Pelco IV SE manual Blank ALL ABOVE/BLANK ALL below

Page 56

BLANK ALL ABOVE/BLANK ALL BELOW

The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are ideal for applications where a complete pan location needs to be blanked.

Blank All Above blanks everything above a user-defined tilt angle. A blanked band will appear at the top of the screen.

Blank All Below blanks everything below a user-defined tilt angle. A blanked circle will appear below the specified angle. Refer to Table C on page 56 and Figure 3 on page 56 for available settings.

The default setting for both Blank All Above and Blank All Below is OFF.

Table C. Window Blank Settings

 

Blank All Above

 

Blank All Below

 

 

 

 

Tilt Angle

Blanked Area

Tilt Angle

Blanked Area

 

 

 

 

10

10° above horizon to 18° above horizon

10

10° above horizon to 92° below horizon

 

 

 

 

OFF

No blanking

OFF

No blanking

 

 

 

 

0

Horizon to 18° above horizon

0

Horizon to 92° below horizon

 

 

 

 

-10

18° above horizon to 10° below horizon

-10

10° to 92° below horizon

 

 

 

 

-20

18° above horizon to 20° below horizon

-20

20° to 92° below horizon

 

 

 

 

-30

18° above horizon to 30° below horizon

-30

30° to 92° below horizon

 

 

 

 

-40

18° above horizon to 40° below horizon

-40

40° to 92° below horizon

 

 

 

 

-50

18° above horizon to 50° below horizon

-50

50° to 92° below horizon

 

 

 

 

-60

18° above horizon to 60° below horizon

-60

60° to 92° below horizon

 

 

 

 

-70

18° above horizon to 70° below horizon

-70

70° to 92° below horizon

 

 

 

 

-80

18° above horizon to 80° below horizon

-80

80° to 92° below horizon

 

 

 

 

CAMERA

8 0

18

10

HORIZON

10

20

30

40

5 0

6

0

7 0

Figure 3. Window Blank Tilt Angles

56

C3434M-A (9/07)

Image 56
Contents Spectra IV SE Horizon Series Dome Drive Page Contents Shutter Speed Scheduled Events Welcome SW1 Receiver Address InstallationSwitch Settings SW2 Switches 1-3 Special System Settings SW2 Switches 4-5 Serial Port SettingsSW2 Switches 6-8 Baud Settings BaudDome Drive Installation Dome Drive InstallationTable A. Switch Settings for SW1 P-Type Control Table B. Switch Settings for SW1 D-Type Control Spectra Switch Setting AddressTable B. Switch Settings for SW1 D-Type Control 100 106 141 176 211 246 Configure Done Getting StartedHow to Operate Your Dome System Accessing Main Menu Preset Quick Programming GuideCM9500 Press the Spot Monitor keyEndura Workstation VCD5000Spectra IV SE Horizon Menu Tree Dome Settings Camera Language System Information Back Exit AdditionalDisplay Setup Label Positions Dome Settings CameraType of Lighting Auto FocusZoom Limit Zoom SpeedLOW Light Limit HighDark IR CUT FilterYES Advanced Camera Settings Shutter SpeedAGC Limit Numeric ValueAuto Iris Auto iris is disabled, and control is always manualDetermined by the auto iris level setting Level. Sharpness level settings range from Auto SharpnessAuto White Balance GainThere are two backlight compensation settings Backlight Compensation BLCVideo Level Wide Dynamic RangeSet the video output to one of the following NormalDefault Electronic Image StabilizationImage Enhancement EnhancedMotion Settings There are two auto flip modes On defaultAuto Flip Proportional PANPreset Park TimeAuto Scan Frame ScanPreset Freeze Frame There are three preset freeze frame settingsScan Speed Image is never frozenLimit Stops ManualScan Stop is reachedAzimuth Zero None Power UPPower UP Action Dome synchronizes to the internal clock Settings range from zero to 359 degreesLine Sync Presets Following presets are predefined for specific functionsBecomes Pelco Spectra IV SE Horizon Language Enable Motion Detection Following are the settings for motion detection OFF defaultMedium default Average sensitivity Edit Detection AreasMotion Detection Areas Activate AUX Command Triggers a command to AUXAUX Time Edit SchedulePatterns Zones Window Blanking To set a window blanking areaReverse Clear WindowBlank ALL ABOVE/BLANK ALL below Alarms Reset DelayResume SequenceMEDIUM/LOW Normally open Momentary AUXLatching Title Text Edit Title TextClear Password Fixed Date Power LineClock Repeat steps b-d for the ending date and time Follow the instructions in for Fixed DATE, adding Week Event Label EventEvent Type Edit Event Label Edit Event LabelHolidays have no effect on the event Edit EventDate is in the list of holidays Holiday Clear EventList Event April Edit HolidayHoliday occurs on the same date each year Clear Holiday List HolidaysScheduled Events Use this page to record scheduled eventsReset, Cycle Power, Reboot Reset CameraCycle Camera Power Reboot SystemSoftware/Language File Upload Suggested Preventative Maintenance Interlace Inch CCD SpecificationsNtsc PAL Product Warranty and Return Information ISO9001
Related manuals
Manual 96 pages 46.76 Kb

IV SE specifications

The Pelco IV SE is a leading-edge camera system designed specifically for surveillance applications that demand high-quality imaging, flexibility, and robustness. With its sleek design and advanced features, the Pelco IV SE is an essential tool for security professionals aiming to enhance situational awareness and improve monitoring capabilities.

One of the key features of the Pelco IV SE is its impressive image quality. The camera is equipped with advanced image sensors that provide high resolution and clarity, ensuring that critical details are captured even in challenging lighting conditions. Its enhanced low-light performance enables efficient operation in darkness, making it suitable for both day and night surveillance tasks.

In terms of technology, the Pelco IV SE incorporates advanced video compression algorithms, such as H.264 and H.265. These technologies allow for efficient bandwidth utilization while maintaining video quality, enabling long-term storage of data without sacrificing clarity. The camera also supports Power over Ethernet (PoE), simplifying installation by allowing power and data to be transmitted over a single cable, reducing clutter and setup complexity.

Another standout characteristic is its flexibility. The Pelco IV SE is designed for various mounting options, including wall, ceiling, and pole mounts, making it adaptable for different environments and surveillance needs. The camera features a varifocal lens, allowing users to adjust the field of view to capture images from different distances, thus optimizing surveillance coverage.

Additionally, the Pelco IV SE integrates seamlessly with existing security systems, providing compatibility with various video management software platforms. This interoperability ensures that users can incorporate the camera into their broader security infrastructure without significant disruption.

The device also comes with intelligent video analytics capabilities, such as motion detection and facial recognition, enhancing its functionality. These features allow for proactive monitoring, where alerts can be set up for suspicious activities, ensuring timely responses to potential threats.

With its robust construction, the Pelco IV SE is built to withstand harsh environmental conditions. It adheres to specific IP ratings, indicating its resistance to dust and water, making it an ideal choice for both indoor and outdoor surveillance applications. In summary, the Pelco IV SE is a versatile, high-performance camera that combines advanced imaging capabilities, reliable technology, and extensive adaptability to meet the evolving demands of modern security surveillance.