Pelco CC3751H-2 manual Wire Gauge, Cable Type, Maximum Distance, E N G L I S H

Page 6
Wire Gauge

AC operation only - If you are wiring more than one camera to the same transformer, connect one side of the transformer to the same terminal on all cameras, and connect the other side of the transformer to the remaining terminal on all cameras. Failure to connect all of the cameras the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

Table A. Recommended Wire Gauge and Wiring Distances

The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)

 

 

 

 

Wire Gauge

 

 

 

 

Total

 

18

 

16

 

14

 

12

 

10

20

 

 

 

 

vA

(0.5 mm2)

(1.0 mm2)

 

(1.5 mm2)

 

(2.5 mm2)

 

(4.0 mm2)

 

(6.0 mm2)

 

 

 

 

 

 

 

 

 

 

 

10

283

451

 

716

 

1142

 

1811

 

2880

 

(86)

(137)

 

(218)

 

(348)

 

(551)

 

(877)

 

 

 

 

 

 

 

 

 

 

 

Example: A camera that requires 10 vA and is installed 283 feet (86 m) from the transformer would require a minimum wire gauge of 20 AWG.

NOTE: Wire gauges are standard AWG or metric sizes. Distances are calculated in feet; values in parentheses are meters.

Table B. Video Coaxial Cable Requirements

Cable Type*

Maximum Distance

 

 

RG59/U

750 ft (229 m)

RG6/U

1,000 ft (305 m)

RG11/U

1,500 ft (457 m)

 

 

*Minimum cable requirements: 75 ohms impedance All-copper center conductor

All-copper braided shield with 95% braid coverage

6

E N G L I S H

C1988M-B-ML (3/05)

Image 6
Contents INSTALLATION/OPERATION CC3751H-2 DSP Color CameraC1988M-B-ML3/05 English EspañolImportant Safeguards and Warnings E N G L I S HModels Regulatory NoticesDescription E N G L I S HLENS MOUNTING InstallationCamera Layout DC AID AUTO IRIS LENS24 VAC POWER AND VIDEO CONNECTIONSCAMERA MOUNTING 12 VDCMaximum Distance Wire GaugeCable Type E N G L I S HVideo Drive Auto Iris Lens Lens Setup and Focus ProceduresBack Focus Adjustment Direct Drive DC Auto Iris LensSwitch Settings NOR/SHP - SharpnessE N G L I S H E N G L I S H LC - Long Line CompensationCamera Synchronization AC Operation Only E N G L I S HELECTRICAL SpecificationsGENERAL MECHANICALPRODUCT WARRANTY AND RETURN INFORMATION REVISION HISTORYE S P A Ñ O L C1988M-B-ML3/05Modelos Avisos ReglamentariosDescripción E S P A Ñ O LMONTAJE DE LA LENTE Composición de la CámaraInstalación LENTES DE IRIS24 VCA MONTAJE DE LA CÁMARACONEXIONES ELÉCTRICAS Y DE VIDEO 12 VCCDistancia máxima Tamaño de cableTipo de cable Lente de iris automático con comando de videoLentes fijas Ajuste de Foco de FondoLente de iris automático de comando directo CC Lentes de iris manualConfiguración de Interruptores E S P A Ñ O LNOR/SHP - Nitidez 30 campos de integración máximo configuraciónE S P A Ñ O L Sincronización de Cámara Sólo para Suministro Ca E S P A Ñ O LC1988M-B-ML3/05 ELÉCTRICAS EspecificacionesGENERALES MECÁNICASN de manual REVISION HISTORYGARANTÍA ObervacionesTel 800/289-9100 Fax 800/289-9150 International Worldwide Headquarters 3500 Pelco WayClovis, California 93612 USA USA & Canada Tel 1-559/292-1981 Fax 1-559/348-1120