Pelco 2 C1306M-B (10/06) manual Install the Enclosure and Set Pan Position

Page 15

Install the Enclosure and Set Pan Position

1. Check for proper seating of the power module seal. Make sure the seal is fully seated in the groove on the top of the power module.

POWER MODULE SEAL

POWER MODULE

Figure 9. Factory-Installed Power Module Seal

WARNING: Use caution when attaching the enclosure unit to the power module. If the grooves on the top of the power module are damaged, the integrity of the unit could be compromised.

2.Refer to Figure 10 and attach the enclosure unit to the power module. Align the pins of the enclosure unit with the holes of the power module. Carefully mate the enclosure connector to the power module connector.

LOCKING

RING

PIN

HOLE

Figure 10. Attach the Enclosure Unit to the Power Module

WARNINGS:

Total weight of the enclosure component is 34.7 lb (15.71 kg). Use caution when lifting and assembling the pan and tilt component on the power module.

The weight of the enclosure unit must be safely supported during installation.

It is recommended that non-slip gloves be worn during installation.

Avoid thread damage. Never use force when assembling and tightening the threaded components of the system.

3.Turn the body of the enclosure to the left or right to set the pan position of the unit.

WARNING: Do not turn the body of the enclosure more than 200° in either direction or damage to the internal power module cable may occur.

4.With your hands carefully thread the enclosure’s locking ring on the threads of the power module until the threads are completely engaged.

5.Use the supplied spanner wrench to tighten the locking ring and fix the position of the enclosure. After the locking ring has been tightened, tap the end of the handle of the wrench with a hammer or the palm of your hand to ensure a secure fit. Make sure that the pan position is maintained when tightening the locking ring. Tighten the set screw of the locking ring with the supplied 2 mm Allen wrench to secure the locking ring.

C1306M-B (10/06)

15

Image 15
Contents ExSite Ehxm Series Explosionproof Fixed System Contents List of IllustrationsList of Tables Important Safety Instructions Getting Started Methods of InstallationAttach Power Module to Mounting Surface Install the Power ModuleConfiguration of Wire Harness Connect WiringProtocol Settings DIP Switch SettingsOn next Address SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 239 Remove Back Cap of Camera Enclosure Install the Camera ModuleInstall Camera Module SET TAB Center Position Factory-Installed Power Module Seal Install the Enclosure and Set Pan PositionSet the Tilt Angle of the Camera Module Install the Sun Shroud Install the Sun ShroudCamera Module Replacement MaintenanceInstall Camera Module C1306M-B 10/06 Electrical SpecificationsCamera Day/Night 23X Color LowLight 22X Color CAMERA/OPTICSProduct Warranty and Return Information ISO9001