CONNECT WIRING
DANGER: Do not connect the power module to a supply circuit unless all ExSite system components (enclosure, camera module, and power module) are installed.
Refer to the following information to connect the wires and cables as required.
WARNING: When installing this unit, provide access to the communication wires (TX+ and
These communication wires are required even if the system uses Coaxitron® control.
Maximum wire distance for
NOTES:
•Relay 3 is allocated specifically for an external washer (not supplied by Pelco).
•All relays are specified for 32 VDC, 0.5 A.
•Wiring/cable for UTP and fiber optic are not provided on the wire harness. The installer must provide UTP and fiber optic connections.
Configuration of Wire Harness
Wire Color | Function |
|
|
White/Orange | TX+ |
|
|
White/Blue | TX- |
|
|
Red | RX+ |
|
|
Green | RX- |
|
|
Violet/White | Relay 3 NC (washer only) |
|
|
White/Red | Relay 3 COM (washer only) |
|
|
Green/Black | Relay 3 NO (washer only) |
|
|
Gray/White | Relay 2 NC |
|
|
Yellow | Relay 2 COM |
|
|
Violet | Relay 2 NO |
|
|
Brown | Relay 1 NC |
|
|
Gray | Relay 1 COM |
|
|
White/Yellow/Black | Relay 1 NO |
|
|
White/Black/Green | Alarm COM |
|
|
White/Red/Black | Alarm 7 |
|
|
White/Brown/Black | Alarm 6 |
|
|
Orange | Alarm 5 |
|
|
White/Orange/Black | Alarm 4 |
|
|
White/Blue/Black | Alarm 3 |
|
|
White/Brown | Alarm 2 |
|
|
White/Black | Alarm 1 |
|
|
Video Coaxial Cable Requirements
Cable Type* | Maximum Distance |
|
|
RG59/U | 750 ft (229 m) |
|
|
RG6/U | 1,000 ft (305 m) |
|
|
RG11/U | 1,500 ft (457 m) |
|
|
*Cable requirements:
Power Connections 24 VAC
Wire Color | Function |
|
|
Red | AC Hi |
|
|
Black | AC Low |
|
|
Power Connections
Wire Color | Function |
|
|
Black | AC Hi |
|
|
White | AC Low |
|
|
Green/Yellow | Earth Ground |
|
|
Wiring Distances
The following are the recommended maximum distances for 24 VAC and
|
| Wire Gauge |
| ||
Power |
|
|
|
| |
18 | 16 | 14 | 12 | ||
| (1.0 mm2) | (1.5 mm2) | (2.5 mm2) | (3.5 mm2) | |
24 VAC | 27 ft | 43 ft | 69 ft | 110 ft | |
(8 m) | (13 m) | (21 m) | (33 m) | ||
| |||||
|
|
|
|
| |
75 ft | 120 ft | 190 ft | 310 ft | ||
VAC | (23 m) | (36 m) | (58 m) | (94 m) | |
|
|
|
|
|
NOTE: Power consumption is 120 VA per unit. Use a power source with a minimum of 150 VA.
6 |