DIP SWITCH SETTINGS
Configure the receiver address, termination, and baud setting for the system. The DIP switches to configure these settings are located on the top of the power module.
NOTE: No DIP switch settings are required for Coaxitron control.
Figure 3 shows the default settings for the DIP switches. Refer to the following to configure the ExSite system settings.
All other switches are set to the OFF position.
1 | 2 3 | 4 | 5 | 6 | 7 8 |
|
| SW1 |
| on | |
|
|
|
|
|
1 SW2
1 on
2 3 | 4 | 5 | 6 | 7 8 |
| SW3 |
|
|
ON
Figure 3. Default DIP Switch Settings
PROTOCOL SETTINGS
The ExSite system automatically detects the type of protocol. No switch settings are required to set Coaxitron or
RECEIVER ADDRESS SETTINGS (SW1)
The default address is 2 for P protocol. Refer to Table A for address settings that use P protocol. Maximum number of receivers is 32.
The default address is 1 for D protocol. Refer to Table B for address settings that use D protocol. Maximum number of receivers is 254.
TERMINATION SETTING (SW2)
When connecting more than one ExSite system to a single controller, terminate the unit farthest from the controller. Termination is required only for the last unit in the series. The unit is shipped from the factory in the unterminated OFF position. To terminate the unit, set the SW2 switch to the ON position.
BAUD SETTINGS (SW3)
Pelco’s
Switch Settings for SW3
Switch Number |
|
|
|
|
|
|
|
2400 Baud | Off | Off | Off |
|
|
|
|
4800 Baud | On | Off | Off |
|
|
|
|
9600 Baud | Off | On | Off |
|
|
|
|
7 |