Pelco ECP290 Example C Validation of 1no. Access Pass, Example D Block Deletion of Access Passes

Page 11

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly deleted Holder Number 074. Programming mode beep - every 4 seconds - resumes.

Example C: Validation of 1no. Access Pass

You have just received the additional Access Pass ordered for Alan Jones who had lost his earlier in the week. The last 3no. digits on the Access Pass are 176. Alan Jones is now Holder Number 176 and you have to program the system to accept Holder Number 176.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly programmed new Holder Number 176. Programming mode beep - every 4 seconds - resumes.

Example D: Block Deletion of Access Passes

You have just been informed that a set of 20 Access Passes reserved for visitors and held in reception have been stolen. You have to immediately delete them to restore system security. The Holder Numbers stolen were 080-099.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A series of 3no. beeps followed by a sharper beep confirms that you have deleted the Holder Numbers. Programming mode beep - every 4 seconds - resumes.

Example E: Changing the Relay/Lock Output Time

You have been asked to change the Relay Output Time to 12 seconds.

Enter the current Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly reprogrammed the relay output time for 12 seconds. Programming mode beep - every 4 seconds - resumes.

Example F: Changing the Master Code

You have been asked to change the Master Code to 11821.

Enter the current Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the new Master Code. Programming mode beep - every 4 seconds - resumes.

11

Image 11
Contents Door Controllers Contents ALL Access Passes are ECP Door Controller Noralsy ECP Door ControllersImportant -If not Monitoring Door Open/Closed Status ECP 190 Door Controller ECP190 Door Controller for N0 Door/Access PointCapacity 999 Users ECP 290 Door Controller ECP290 Door Controller for 2n0 Doors/Access PointsCapacity 999 Users per door Access Control Modules with integral Infra-Red Programming using Telpro as a hard-wired programmer Programming using Telpro as a remote wire-free programmer02A0 ECP Door Controller with000005 Example Site Code = Example a Block Loading/Validation of Access PassesExample B Deletion of 1no. Access Pass Example F Changing the Master Code Example C Validation of 1no. Access PassExample D Block Deletion of Access Passes Example E Changing the Relay/Lock Output TimeAdditional Features of ECP290 Tip Wizard ECP190 Door Controller Noralsy ECP Door ControllerDIN Rail Mounting Noralsy DIN Rail Power Supplies ARE122 + ECP290 ECP190 Door Controller with Keypad Access Code ControlChanging the Master Code Access Control Modules