Pelco ECP190, ECP290 Example Site Code =, Example a Block Loading/Validation of Access Passes

Page 10

STEP 4

You must now inform the Door Controller of the Site Code of the Access Passes supplied.

The Site Code is always stored in Slot No. 01.

The Site Code is always a 5 digit number.

Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you the Site Code of the Access Passes delivered.

*

Example: Site Code = 45801

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the Site Code. Programming mode beep - every 4 seconds - resumes.

*KBP Proximity Cards have the full site code printed on each card.

STEP 5

You must now inform the Door Controller of the Access Pass Holder Numbers supplied.

Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you which Holder Numbers we have supplied.

Example: 150no. Access Passes Supplied

HOLDER NUMBERS 001-150.

After a beep enter on the TELPRO:

*See Tip Wizard on page 13

A series of 3no. beeps followed by a sharper beep confirms that you have correctly entered the Holder Numbers. Programming mode beep - every 4 seconds - resumes.

STEP 6

Turn off programming switch SW1 in the Door Controller. You have successfully programmed the system. The Access Passes should now all work.

ADVANCED PROGRAMMING

In the following examples of programming we are assuming that the Master Code = 19388. This is purely for demonstration purposes. When programming for real, you must enter the Master Code that you chose and set when the system was installed.

Example A: Block Loading/Validation of Access Passes.

You have just received an additional 25no. Access Passes for the system. Holder Numbers 151- 175.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the TELPRO:

A series of 3no. beeps followed by a sharper beep confirms that you have correctly entered the Holder Numbers. Programming mode beep - every 4 seconds - resumes.

Example B: Deletion of 1no. Access Pass

You have just been informed that Alan Jones has lost his Access Pass. Alan was Holder Number 074. You have to delete it immediately to restore system security. Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming Mode.

10

Image 10
Contents Door Controllers Contents ALL Access Passes are Important -If not Monitoring Door Open/Closed Status Noralsy ECP Door ControllersECP Door Controller Capacity 999 Users ECP190 Door Controller for N0 Door/Access PointECP 190 Door Controller Capacity 999 Users per door ECP290 Door Controller for 2n0 Doors/Access PointsECP 290 Door Controller Access Control Modules with integral Infra-Red Programming using Telpro as a remote wire-free programmer Programming using Telpro as a hard-wired programmer000005 ECP Door Controller with02A0 Example B Deletion of 1no. Access Pass Example a Block Loading/Validation of Access PassesExample Site Code = Example E Changing the Relay/Lock Output Time Example C Validation of 1no. Access PassExample D Block Deletion of Access Passes Example F Changing the Master CodeAdditional Features of ECP290 Tip Wizard Noralsy ECP Door Controller ECP190 Door ControllerDIN Rail Mounting Noralsy DIN Rail Power Supplies ARE122 + ECP290 Keypad Access Code Control ECP190 Door Controller withChanging the Master Code Access Control Modules