ECP290 DOOR CONTROLLER FOR 2 DOORS – IMPORTANT

INFORMATION

FLICKING PROGRAMMING SWITCH SW1.

The access control readers on both doors will start to beep every 4 seconds indicating programming mode status. Only 1 no. access point (door) can be programmed at a time.

IF USING THE TELPRO PROGRAMMER IN WIREFREE INFRA-RED MODE:

Simply point at the relevant reader to effect programming for its related access point (door). Repeat the process for the 2nd access control reader on the ECP290. Remember to turn off programming switch SW1 when finished.

IF USING TELPRO PROGRAMMER IN HARDWIRED MODE:

Connect as follows:

J5 for the reader connected to I2A1, Access Point 1.

J6 for the reader connected to I2A2, Access Point 2.

Remember to turn off programming switch SW1 when finished.

Note: Programming mode can, of course, be accessed via entering the Master Code (the code stored in Slot No. 06) as explained earlier.

ADDITIONAL FEATURES OF ECP290

Activating one of the additional features offered by the ECP290 is very straightforward and involves a very slight modification of Step 1 (see page 9) of the Programming Operation.

Remember: The programming operation has to be effected for each access point (door).

00000508 = Standard Set-Up, adequate for the vast majority of installations. If this is sufficient, simply copy the procedure, as explained on page 9, for both doors.

Mode 2 - Access Pass to Operate Only if Vehicle Present

00200500 = Set-Up, Mode 2

È

Alarm delay time in minutes. A 00 setting disables the alarm function.

When a valid access pass is presented to the reader, the relay output will be activated for 2 seconds BUT ONLY IF the Magnetic Induction Loop (M.I.L) contacts, terminals 1 & 2 of J10A1 or J10A2, have closed ie a vehicle is present. If the M.I.L contacts remain closed for longer than the preset alarm delay time, the access control reader/receiver/keypad will sound an alarm.

Mode 3 - Access Pass to Operate Only if Door Closed

00300500 = Set-Up, Mode 3

È

Alarm delay time in minutes. A 00 setting disables the alarm function.

The status of the door is controlled by 2no. sets of contacts as follows:

Open Position Reached (OPR) Contacts:

Terminals 2

& 3 of J10A1 (Access Point 1)

Door Open Contacts (DO):

Terminals 3

& 4 of J9A1

(Access Point 1)

Open Position Reached (OPR) Contacts:

Terminals 2

& 3 of J10A2 (Access Point 2)

Door Open Contacts (DO):

Terminals 3

& 4 of J9A2

(Access Point 2)

When a valid access pass is presented to the reader, the relay output will be activated for 2 seconds BUT ONLY IF the related Access Point (Door) is closed. If the Access Point (Door) remains open for longer than the preset alarm delay time (DO Contacts OPEN and OPR Contacts CLOSED) or, if the Access Point (Door) is blocked/stuck for longer than the preset alarm delay time (DO Contacts OPEN and OPR Contacts OPEN), the access control reader/receiver/keypad

will sound an alarm.

12

Image 12
Contents Door Controllers Contents ALL Access Passes are Noralsy ECP Door Controllers Important -If not Monitoring Door Open/Closed StatusECP Door Controller ECP190 Door Controller for N0 Door/Access Point Capacity 999 UsersECP 190 Door Controller ECP290 Door Controller for 2n0 Doors/Access Points Capacity 999 Users per doorECP 290 Door Controller Access Control Modules with integral Infra-Red Programming using Telpro as a remote wire-free programmer Programming using Telpro as a hard-wired programmerECP Door Controller with 00000502A0 Example a Block Loading/Validation of Access Passes Example B Deletion of 1no. Access PassExample Site Code = Example C Validation of 1no. Access Pass Example D Block Deletion of Access PassesExample E Changing the Relay/Lock Output Time Example F Changing the Master CodeAdditional Features of ECP290 Tip Wizard Noralsy ECP Door Controller ECP190 Door ControllerDIN Rail Mounting Noralsy DIN Rail Power Supplies ARE122 + ECP290 Keypad Access Code Control ECP190 Door Controller withChanging the Master Code Access Control Modules