Pelco ECP290, ECP190 manual ECP Door Controller with, 000005, 02A0

Page 9

ECP Door Controller with

ACCESS PASS CONTROL

TOP POINTS TO REMEMBER

Programming is effected via the TELPRO programming keypad.

Site Code is always a 5 digit number.

Site Code is always stored in Slot No. 01.

Master Code (Programming Access Code) is always a 5 digit number.

Master Code is always stored in Slot No. 06.

PROGRAMMING

TIP - WHEN YOU ARE PROGRAMMING

It is a good idea to have written down in advance what you want to program. Enter the numbers in quick succession after a beep. Do not wait more than 2-3 seconds in between entering numbers as this will confuse the system.

SET-UP ON INSTALLATION

Wire up according to appropriate electrical wiring schematic for your installation, then power up the Door Controller. Flick the Programming Switch SW1. The unit will start beeping every 4 seconds.

STEP 1

Decide Now -- For how many seconds do you want the door to open:

After a beep enter on the TELPRO:

000005 08

Example

08

seconds

Basic configuration, just do it!

The last 2no. digits, shown as underlined, set the door open time in seconds. You can choose any length between 01 - 99 seconds. For automation control, 01 seconds is usually more than adequate.

A sharp beep confirms that you have correctly entered the above. Programming mode beep - every 4 seconds - resumes.

STEP 2

 

02A0

Basic configuration,

After a beep enter on the TELPRO:

just do it!

A sharp beep confirms that you have correctly entered the above. Programming mode beep - every 4 seconds - resumes.

STEP 3

You must now set the Master Code of your choice. This is the code that allows you to access programming mode without having to open up the Door Controller and flicking switch SW1.

The Master Code is always stored in Slot No. 06.

The Master Code must be a 5 digit number, for example: 19388.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the Master Code. Programming mode beep - every 4 seconds - resumes.

9

Image 9
Contents Door Controllers Contents ALL Access Passes are Noralsy ECP Door Controllers Important -If not Monitoring Door Open/Closed StatusECP Door Controller ECP190 Door Controller for N0 Door/Access Point Capacity 999 UsersECP 190 Door Controller ECP290 Door Controller for 2n0 Doors/Access Points Capacity 999 Users per doorECP 290 Door Controller Access Control Modules with integral Infra-Red Programming using Telpro as a hard-wired programmer Programming using Telpro as a remote wire-free programmerECP Door Controller with 00000502A0 Example a Block Loading/Validation of Access Passes Example B Deletion of 1no. Access PassExample Site Code = Example D Block Deletion of Access Passes Example C Validation of 1no. Access PassExample E Changing the Relay/Lock Output Time Example F Changing the Master CodeAdditional Features of ECP290 Tip Wizard ECP190 Door Controller Noralsy ECP Door ControllerDIN Rail Mounting Noralsy DIN Rail Power Supplies ARE122 + ECP290 ECP190 Door Controller with Keypad Access Code ControlChanging the Master Code Access Control Modules