Pelco ECP290, ECP190 manual Access Control Modules with integral Infra-Red

Page 7

Programming Stand-Alone Access Control Systems using TELPRO™ Programmer.

®

TELPRO™ PROGRAMMER

The TELPRO™ Programmer is a handheld keypad used for programming Noralsy® stand-alone access control systems.

Installation companies only ever need 1no. TELPRO™ Programmer.

TELPRO™ can be used on any system provided, of course, the Master Code (also referred to as the Engineer Code) which grants access into programming mode is known or, access to the ECP Door Controller itself is available.

The final customer only needs a TELPRO™ unit if they wish to effect programming themselves.

Access Control Modules with integral Infra-Red

MLP3 Proximity

The TELPRO™ Programmer can be used as a wirefree infra-red programmer. Simply point at the reader/receiver module to program.

MIR Infra-Red

TELPRO™

Programmer

Access Control Modules, Readers, Receivers without integral Infra-Red

The TELPRO™ Programmer is supplied with a connector cable. Simply connect to ECP Door Controller to program.

TELPRO™

Programmer

Dim:

120L x 60W x 25D

ECP190

ECP290

ECP100

ECP200

LTP03

LB20 Swipe Card

 

Office Proximity Reader

MILB Card Reader

 

LHF

Radio receiver

If the entrance or door panel includes a MICAM/MICIM Keypad Module connected to the ECP Door Controller, all programming can be effected directly via the MICAM/MICIM Keypad ie. TELPRO™ Programmer would not be required. You would also then have the option of having keypad access codes.

All measurements in millimetres.

7

Image 7
Contents Door Controllers Contents ALL Access Passes are Important -If not Monitoring Door Open/Closed Status Noralsy ECP Door ControllersECP Door Controller Capacity 999 Users ECP190 Door Controller for N0 Door/Access PointECP 190 Door Controller Capacity 999 Users per door ECP290 Door Controller for 2n0 Doors/Access PointsECP 290 Door Controller Access Control Modules with integral Infra-Red Programming using Telpro as a hard-wired programmer Programming using Telpro as a remote wire-free programmer000005 ECP Door Controller with02A0 Example B Deletion of 1no. Access Pass Example a Block Loading/Validation of Access PassesExample Site Code = Example F Changing the Master Code Example C Validation of 1no. Access PassExample D Block Deletion of Access Passes Example E Changing the Relay/Lock Output TimeAdditional Features of ECP290 Tip Wizard ECP190 Door Controller Noralsy ECP Door ControllerDIN Rail Mounting Noralsy DIN Rail Power Supplies ARE122 + ECP290 ECP190 Door Controller with Keypad Access Code ControlChanging the Master Code Access Control Modules