POSITIONING THE FLUE TERMINAL

I

F

J

L

P

Q

Q

 

 

 

 

 

D,E

B

C

O

G

A

H

 

 

I

H

Q

N

M

N

M

 

K

 

 

 

 

 

 

 

 

 

 

 

Dimension

Terminal Position

Distance

 

 

 

A

Directly below an opening, air brick, opening windows, etc.

300mm

 

 

 

B

Above an opening, air brick, opening window, etc.

300mm

 

 

 

C

Horizontally to an opening, air brick, opening window, etc.

300mm

 

 

 

D

Below gutters, soil pipes or drain pipes.

75mm

 

 

 

E

Below eaves.

200mm

 

 

 

F

Below balconies or car port roof.

200mm

 

 

 

G

From a vertical drain pipe or soil pipe.

150mm

 

 

 

H

From an internal or external corner.

200mm

 

 

 

I

Above ground, roof or balcony level.

300mm

 

 

 

J

From a surface facing the terminal.

600mm

 

 

 

K

From a terminal facing a terminal.

1200mm

 

 

 

L

From an opening in a car port. (e.g. door, window) into a dwelling.

1200mm

 

 

 

M

Vertically from a terminal on the same wall.

1500mm

 

 

 

N

Horizontally from a terminal on the same wall.

300mm

 

 

 

O

From the wall on which the terminal is mounted

N/A

 

 

 

P

From a vertical structure on the roof.

N/A

 

 

 

Q

Above an intersection with roof.

N/A

 

 

 

– 28 –

Image 28
Contents RHFE-308 FTR Contents Getting to Know Your NEW RHFE-308FTR LouvreRemote Control OFFControl Panel Layout On / OFFFeatures Filter Indicator Remote ControlEconomy Mode Auto ComfortSafety Points Clean with vacuum cleaner, weekly Operating Your NEW RHFE-308FTR To Open the Control PanelTurning on Turning OFFRoom Temperature Adjustment Child Lock Economy Timer 1 Timer 2 Override Vertical Louvre Adjustment Do not remove filter when appliance is operatingFAN Filter Humidifier TraySetting the Clock Programming the ON/OFF Timers Turn to Next page to Operate the TimersOperating the Timers SET and Forget OperationTime Elapsed from Ignition to Preset Temperature PRE-HEATUsing the Remote Control To Change TemperatureOverride Function To Turn on or OFFCaring for Your NEW RHFE-308FTR Do not USE SolventsPRE-SERVICE Check At IgnitionError Messages Code Displayed Fault RemedyInstallation Instructions Important Safety InstructionsSpecification Location This heater is not designed to be builtStandard Installation of Flue Manifold Flue SizesSnow Areas FIT Back Covers Sides onlyFlue Manifold Position Wall Mounting BracketsInstalling the Flue GeneralDimension Terminal Position Distance Positioning the Flue TerminalSleeve and Manifold Installation Method for Standard WallsCheck rubber seal is in place on terminal AIR Inlet Hose Fitting UnitExhaust Pipe & Locking Clamp Forced Flue Heater Extension Kits Names and Numbers of PartsHOW to Install Installing AN Extension KIT for the RHFE-308 FTRFlue Extension Kits Air intake hose Hose joint Metres less 1m per bend to a max 3 bends Maximum extendable lengthTo prevent water condensation Conversion Fig #2 Fig #3Connecting GAS and Electrical Services Electrical ConnectionTesting Unit TestingFault Finding Procedure GAS Pressure Setting Satisfactory Unsatisfactory Front View Heater is now secured to the wall Fitting TOP Spacer and Wall ClipInstruct Customer on USE of Heater Block Diagram Wiring Diagram RHFE-308FTRDimensions Flue Position Through Wall Specification RHFE-308 FTRPage Service Contact

RHFE-308 FTR specifications

The Rinnai RHFE-308 FTR is an advanced heating appliance designed to deliver efficient and comfortable warmth, especially in residential settings. It has become a popular choice for homeowners seeking reliable heating solutions that also emphasize energy efficiency and sustainability.

One of the standout features of the Rinnai RHFE-308 FTR is its innovative technology known as "Flue Gas Heat Recovery." This technology allows the heater to utilize the heat generated by combustion to enhance the overall efficiency of the unit. By capturing and repurposing flue gases, the RHFE-308 FTR can provide superior heating performance while minimizing energy waste, making it an environmentally friendly option.

The unit is equipped with a powerful burner system that generates impressive heat output while maintaining low emissions. This not only ensures effective heating but also complies with stringent environmental regulations, contributing to a cleaner atmosphere. Additionally, the Rinnai RHFE-308 FTR is designed to operate quietly, allowing homeowners to enjoy a warm and peaceful environment.

Ease of use is another appealing characteristic of the RHFE-308 FTR. It features a user-friendly control panel, which allows for precise temperature adjustments. Homeowners can set their desired comfort level with just a few simple clicks. This model also includes programmable timer options, enabling users to schedule heating times that align with their daily routines, further enhancing convenience and energy savings.

The compact and sleek design of the RHFE-308 FTR ensures that it can easily blend into various interior styles without looking out of place. It’s also lightweight, making installation straightforward for both professional technicians and savvy DIY enthusiasts. The unit’s construction emphasizes durability, featuring high-quality materials that ensure longevity and reliable performance over time.

Safety is a paramount consideration in the design of the Rinnai RHFE-308 FTR. It comes with multiple safety features, such as overheat protection and a child safety lock, providing peace of mind for families.

Overall, the Rinnai RHFE-308 FTR stands out as a versatile and efficient heating solution. With its advanced technology, user-friendly features, and emphasis on safety, it offers a comfortable and reliable heating experience for modern homes.